A part of Merck

150833 | LiChrospher® 100 RP-18 (5 µm) LiChroCART® 250-4

150833
Price could not be retrieved
Minimum Quantity needs to be mulitiple of
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Limited AvailabilityLimited Availability
In Stock 
Discontinued
Limited Quantities Available
Availability to be confirmed
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      View Pricing & Availability
      Click To Print This Page

      Overview

      Replacement Information

      Key Spec Table

      Pricing & Availability

      Catalogue NumberAvailability Packaging Qty/Pack Price Quantity
      1508330001
      Retrieving availability...
      Limited AvailabilityLimited Availability
      In Stock 
      Discontinued
      Limited Quantities Available
      Availability to be confirmed
        Remaining : Will advise
          Remaining : Will advise
          Will advise
          Contact Customer Service

          Fibre case 1 unit
          Retrieving price...
          Price could not be retrieved
          Minimum Quantity needs to be mulitiple of
          Upon Order Completion More Information
          You Saved ()
           
          Request Pricing
          1508331003
          Retrieving availability...
          Limited AvailabilityLimited Availability
          In Stock 
          Discontinued
          Limited Quantities Available
          Availability to be confirmed
            Remaining : Will advise
              Remaining : Will advise
              Will advise
              Contact Customer Service

              Fibre case unit
              Retrieving price...
              Price could not be retrieved
              Minimum Quantity needs to be mulitiple of
              Upon Order Completion More Information
              You Saved ()
               
              Request Pricing
              Description
              Catalogue Number150833
              OverviewLiChrospher® RP-18 is a reliable and versatile traditionally produced spherical silica gel carrier with C-18 reversed phase properties. It is well suited for the separation of neutral, acidic and weak basic compounds. This  sorbent is packed into a LiChroCART® 250-4 HPLC cartridge. The connection to the HPLC system is being accomplished by use of the manu-CART® NT cartrige holder (1.51486).
              References
              Product Information
              HS Code9027 90 50
              Applications
              Biological Information
              Physicochemical Information
              Dimensions
              Materials Information
              Toxicological Information
              Safety Information according to GHS
              Storage class10 - 13 Other liquids and solids
              Safety Information
              Product Usage Statements
              Storage and Shipping Information
              StorageStorage temperature: no restrictions.
              Packaging Information
              Transport Information
              Supplemental Information
              Specifications
              Pressure≤ 110 bar
              Theoretical Plates (N/m) (Toluene)≥ 50000
              Symmetry (Toluene)0.8 - 1.4
              Capacity factor (Toluene)1.0 - 2.5

              Documentation

              SDS

              Title

              Safety Data Sheet (SDS) 

              Certificates of Analysis

              Product Number PackagingSpecificationLot Number
              1508330001 Fibre casePDF Specification Document
              1508331003 Fibre casePDF Specification Document

              Application Notes

              Title
              Additives & Sweeteners in Chewing gum - separation of Aspartame, L-Aspartyl-L-phenylalanine methyl ester - using a LiChrospher RP-18 column
              Alcohol in Biological sample - separation of Ethyl alcohol - using a LiChrospher RP-18 column
              Alkoloids in Coffee - separation of Chlorogenic acid isomer, n-Chlorogenic acid, Caffeine - using a LiChrospher RP-18 column
              Alkoloids in Meconium - separation of Cotinine, Caffeine, Nicotine - using a LiChrospher RP-18 column
              Amino acids (Standards) - separation of 18 PAZ derivatized amino acids - using a LiChrospher RP-18 column
              Amino acids in Plasma - separation of Homocysteine - using a LiChrospher RP-18 column
              Amino acids in Pork tissue - separation of Homocysteine - using a LiChrospher RP-18 column - fluorescence detection
              Analgesics in Pharmaceutical formulation - separation of Paracetamol, Caffeine, Ascorbic acid, Phenylephrine hydrochloride - using a LiChrospher RP-18 column
              Anthraquinones in Serum - separation of 9,10-Anthraquinone-2-carboxylic acid - using a LiChrospher RP-18 column
              Antibiotics (Standards) - separation of Ciprofloxacin hydrochloride - using a LiChrospher RP-18 column
              Antibiotics in Pharmaceutical formulation - separation of Ciprofloxacin - using a LiChrospher RP-18 column
              Antibiotics in Urine - separation of Cefadroxil - using a LiChrospher RP-18 column - ion-pair method
              Antibiotics in Urine - separation of Cefuroxime - using a LiChrospher RP-18 column
              Antimicrobials in Shampoo - separation of 2-Mercaptopyridine - using a LiChrospher RP-18 column
              Antimicrobials in Shampoo - separation of 2-Mercaptopyridine, 2,2'-Dithiobis(pyridine 1-oxide), 2,2'-Dithiodipyridine, Copper pyrithione - using a LiChrospher RP-18 column
              Antimicrobials in Shampoo - separation of 2-Mercaptopyridine, 2-Mercaptopyridine-1-oxide - using a LiChrospher RP-18 column
              Antimicrobials in Shampoo - separation of Copper pyrithione - using a LiChrospher RP-18 column
              Antineoplastic in Serum, Plasma - separation of Etoposide - using a LiChrospher RP-18 column
              Antioxidant BHA in Soup - separation of 3-tert-Butyl-4-hydroxyanisole, 3,4-Dimethylphenol - using a LiChrospher RP-18 column
              Aromatic acids in Plasma - separation of Acetylsalicylic acid, Salicylic acid, Ethyl 4-hydroxybenzoate - using a LiChrospher RP-18 column
              Asthma medication in Plasma - separation of Fenoterol - using a LiChrospher RP select B column - fluorescence detection
              Benzodiazepines in Plasma - separation of Alprazolam, Diazepam, Nordiazepam - using a LiChrospher RP-18 column
              Beta blockers in Plasma - separation of Phenylbutazone, Tolfenamic acid - using a LiChrospher RP-18 column
              Beta blockers in Rabbit liver - separation of Oxprenolol - using a LiChrospher RP-18 column
              Biogenic amines in Cheese - separation of Putrescine, Cadaverine, Histamine, Tyramine - using a LiChrospher RP-18 column
              Biogenic amines in Peach - separation of Putrescine, Spermidine - using a LiChrospher RP-18 column
              Biogenic amines in Wine - separation of Tryptamine, Phenylethylamine, Putrescine, Cadaverine, Histamine, Tyramine, Spermidine, Spermine - using a LiChrospher RP-18 column
              Cancer medication in Plasma - separation of 13-S-Dihydrodoxorubicin, 13-S-Dihydroepirubicin, Epirubicin, Doxorubicin - using a LiChrospher RP-18 column
              Cancer medication in Plasma - separation of 5-Fluorouracil - using a LiChrospher RP-18 column
              Cancer medication in Wipe sample - separation of Methotrexate - using a LiChrospher RP-18 column
              Carbon cluster C60 & C70 (Standards) - separation of C60, C70 - using a LiChrospher RP-18 column
              Catecholamines & Neurotransmitters in Urine - separation of Adrenaline, Noradrenaline - using a LiChrospher RP-18 column - fluorescence detection and ion-pair
              Chlorophylls in Reaction mixture - separation of Chlorins, magnesium chelated - using a LiChrospher RP-18 column with LC-MS detection
              Cosmetic sample in Shampoo - separation of 2-Mercaptopyridine, 2,2'-Dithiobis(pyridine 1-oxide), 2,2'-Dithiodipyridine, 2-Mercaptopyridine-1-oxide - using a LiChrospher RP-18 column
              Dihydroxyacetone in Cosmetic Cream - separation of Dihydroxyacetone and related compounds as 2,4-Dinitrophenylhydrazine derivatives - using a LiChrospher RP-18 column
              Diuretics in Plasma - separation of Furosemide - using a LiChrospher RP-18 column - fluorescence detection
              EDTA in Water - separation of EDTA - using a LiChrospher RP-18 column
              Environmental (Standards) - separation of Acetaldehyde, Acetone, Acrolein, Benzaldehyde, 2-Butanone, Butyraldehyde, Crotonaldehyde, Formaldehyde, Hexaldehyde, Methacrolein, Propionaldehyde - using a LiChrospher RP-18 column
              Expectorant in Expectorant - separation of Ambroxol hydrochloride - using a LiChrospher RP-18 column
              Explosives in Water - separation of 2-Naphthol, 1-Naphthol, 2,4-Dichlorophenol, 4-Dinitrotoluene, 2-Nitrotoluene, 4-Nitrotoluene, 3-Nitrotoluene - using a LiChrospher RP-18 column
              Fatty acids in Plasma - separation of Palmitic acid, Palmitoleic acid, Stearic acid, Oleic acid, Linoleic acid, Arachidonic acid - using a LiChrospher CN column
              Flavone C-Glycosides in Plant material - separation of Apigenin, Isoorientin, and Isovitexin glucosides - using a LiChrospher RP-18 column
              Flavonoids, Polyphenols & Phytopharma in Apple - separation of Flavanols, Phenolic acids - using a LiChrospher CN column
              Flavonoids, Polyphenols & Phytopharma in Grape seed - separation of Procyanidins - using a LiChrospher RP-18 column
              Flavonoids, Polyphenols & Phytopharma in Honey - separation of Myricetin, Tricetin, Quercetin, Luteolin, Kaempferol - using a LiChrospher RP-18 column
              Flavonoids, Polyphenols & Phytopharma in Orange - separation of Hesperidin - using a LiChrospher RP-18 column
              Flavonoids, Polyphenols & Phytopharma in Plant material - separation of Flavones, Isothymusin, Pedunculin, Pilosine - using a LiChrospher RP-18 column with LC-MS detection
              Flavonoids, Polyphenols & Phytopharma in Plant material - separation of Lutonarin, Saponarin, Isovitexin, Vitexin, Isovitexin, Caffeic acid, saponarin ester - using a LiChrospher RP-18 column
              Flavonoids, Polyphenols & Phytopharma in Plasma - separation of Anthocyanins - using a LiChrospher RP-18 column
              Flavonoids, Polyphenols & Phytopharma in Vegetable - separation of Caffeoylquinic acids - using a LiChrospher RP-18 column
              Flavonoids, Polyphenols & Phytopharma in White lupin - separation of White lupin isoflavonoids - using a LiChrospher RP-18 column
              Flavonoids, Polyphenols & Phytopharma in Wine - separation of cis-Resveratrol glucoside, trans-Resveratrol glucoside - using a LiChrospher RP-18 column
              Food Safety, Agriculture and Environmental in Food - separation of Hydroxymethylfurfural, Furfural - using a LiChrospher RP-18 column
              Food dyestuffs (Standards) - separation of Fluorescein monogluconide, Fluorescein - using a LiChrospher RP-18 column - fluorescence detection and ion-pair
              Fungicides in Serum - separation of Fluconazole - using a LiChrospher RP-18 column
              Glucosides in Red wine - separation of ten glycosides - using a LiChrospher RP-18 column
              Glycosides in Allium porrum - separation of Saponins - using a LiChrospher RP-18 column
              Lipids in Plasma - separation of BAY X 7195 - using a LiChrospher RP-18 column - fluorescence detection
              Metal ions in Reaction mixture - separation of Benzoic acid - using a LiChrospher RP-18 column - ion-pair method
              Mycotoxins in Food - separation of Trichothecenes, Type A - using a LiChrospher RP-18 column - fluorescence detection
              Mycotoxins in Milk - separation of Fumonisin B1 - using a LiChrospher RP-18 column - fluorescence detection
              Mycotoxins in Wheat, Soy bean, Corn - separation of Penicillium mycotoxins, Brefeldin A, Citreoviridin A, Griseofulvin, Citrinin, Patulin, Aspergillus mycotoxin, Ochratoxin A - using a LiChrospher RP-18 column
              Nucleosides/tides in Human urine - separation of Nucleosides - using a LiChrospher RP-18 column
              Nucleosides/tides in Nucleosides - separation of Nucleotide ApUpG, Nucleotide ApApA, Nucleotide ApApG, Nucleotide ApApU - using a LiChrospher RP-18 column - ion-pair method
              Nucleosides/tides in Pork tissue - separation of Nucleotides - using a LiChrospher RP-18 column
              Organic acids in Plasma - separation of Oxopropanoic acid, Oxobutyric acid, Oxoisovaleric acid, Oxoisocaproic acid, Oxocaproic acid, Oxovaleric acid - using a LiChrospher RP-18 column - fluorescence detection
              Peptides & Proteins in Impurified product - separation of Peptides - using a LiChrospher RP-18 column with LC-MS detection
              Pesticides (Standards) - separation of Endosulfan, Heptachlor, DDT, Aldrin - using a LiChrospher RP-18 column
              Pesticides (Standards) - separation of Flutriafol - using a LiChrospher RP-18 column
              Pesticides (Standards) - separation of Simazine, Atrazine, Prometon, Propazine, Ametryne, Prometryne, Terbutryne - using a LiChrospher RP-18 column
              Pesticides in Drinking water - separation of Atrazine, Atrazine, degradation products, 4-Chlorobenzoic acid - using a LiChrospher RP-18 column with LC-MS detection
              Pesticides in Medicinal plant - separation of Aldrin, Dieldrin, Endrin, Heptachlor, p,p'-DDT - using a LiChrospher RP-18 column
              Pharma drug in Cattle milk - separation of Isonicotinic acid hydrazine - using a LiChrospher RP-18 column
              Pharmaceutical Alkoloids in Urine - separation of Morphine, Caffeine, Paracetamol, Methyldopa - using a LiChrospher RP-18 column
              Pharmaceutical Alkoloids in Urine - separation of Tramadol glucuronides - using a LiChrospher RP-18 column - fluorescence detection and ion-pair
              Phenolic acids in Caryopsis of wheat, rye, triticale - separation of Caffeic acid, p-Coumaric acid, Ferulic acid, Sinapic acid - using a LiChrospher RP-18 column
              Phenols in Bark - separation of 1,2,3-Trihydroxybenzene, 1,2-Dihydroxybenzene, Hydroxybenzoic acids and Aldehydes - using a LiChrospher RP-18 column
              Phenols in Leaf of Olea europae L. - separation of Phenols - using a LiChrospher RP-18 column
              Phenols in Water - separation of Phenol, p-Cresol, o-Cresol, m-Cresol - using a LiChrospher RP-18 column - fluorescence detection
              Pterins (Standards) - separation of Neopterin, Biopterin, Pterin - using a LiChrospher RP-18 column - fluorescence detection
              R&D sample in Guinea pig plasma - separation of Antibronchospatic agent MX2/120 - using a LiChrospher RP-18 column
              Steroids in Chitosan gelatin sponge - separation of Prednisolone - using a LiChrospher RP-18 column
              Steroids in Gel formulation - separation of Hydrocortisone phosphate disodium - using a LiChrospher RP-18 column
              Steroids in Plasma - separation of Cortisol, Nortestosterone - using a LiChrospher RP-18 column
              Steroids in Rat plasma - separation of Corticosterone - using a LiChrospher RP-18 column
              Steroids in Water - separation of Oestradiol, Oestriol, Oestrone, Ethynyl oestradiol, Mestranol, Diethylstilbestrol, Progesterone, Norethindrone, Levonorgestrel - using a LiChrospher RP-18 column
              Stilbenes in Wine, Must - separation of trans-Resveratrol, cis-Resveratrol - using a LiChrospher RP-18 column
              Sugars in Chitin - separation of Oligosaccharides - using a LiChrospher RP-18 column
              Sugars in Lemon juice concentrate - separation of Saccharin, Sodium benzoate - using a LiChrospher RP-18 column
              Surfactants in Sewage sludge - separation of Linear alcohol ethoxylates - using a LiChrospher RP-18 column - fluorescence detection
              Terpenes in Plant material - separation of Faradiol laurate, Faradiol myristate, Faradiol palmitate - using a LiChrospher RP-18 column
              Test mixture (Aromatic hydrocarbons) (Standards) - separation of Benzene, Ethylbenzene - using a LiChrospher RP-18 column
              Test mixture (Aromatic hydrocarbons) in Petrol - separation of Naphthalene, 2-Methylnaphthalene, 2,6-Dimethylnaphthalene - using a LiChrospher RP-18 column
              Triacylglycerols of the red microalga Porphyridium cruentum can contribute to the biosynthesis of eukaryotic galactolipids
              Vitamins - fat soluble (Standards) - separation of Vitamin A esters, ß-Carotene, Vitamin C, α-Tocopherol, Vitamin E - using a LiChrospher RP-18 column
              Vitamins - fat soluble in Food - separation of Retinol, CarotenoidsCarotenoids - using a LiChrospher RP-18 column
              Vitamins - fat soluble in Olive oil - separation of α-Tocopherol, γ-Tocopherol, δ-Tocopherol - using a LiChrospher RP-18 column
              Vitamins - fat soluble in Plant oil - separation of δ-Tocopherol, γ-Tocopherol, β-Tocopherol, α-Tocopherol - using a LiChrospher RP-18 column - fluorescence detection
              Vitamins - fat soluble in Serum - determination of alpha and gamma Tocopherol metabolites - using a LiChrospher RP-18 column - ion-pair method
              Vitamins - water soluble in Multivitamin juice - separation of Ascorbic acid, Pyridoxine, Nicotinamide, Folic acid, Cyanocobalamin, Riboflavin, Thiamine - using a LiChrospher RP-18 column
              Xanthines in Tobacco - separation of Theobromine, Theophylline, Caffeine, Nicotine, Cotinine, 1,7-Dimethylxanthine, 7-Methylxanthine, 1,3-Dimethyluric acid - using a LiChrospher RP-18 column

              Related Products & Applications

              Accessories (Primary)

              Catalogue Number Description  
              150957 LiChrospher® 100 RP-18 (5 µm) LiChroCART® 4-4 Show Pricing & Availability
              151486 manu-CART® NT cartridge holder for LiChroCART® 2,3,4,4.6 mm i.d. HPLC cartridges Show Pricing & Availability

              Related Products By: Application Facete

              Related Products By: Brand Facete

              Categories

              Analytics and Sample Preparation > Analytical Chromatography > Analytical HPLC > LiChrospher® HPLC Columns and Sorbents > LiChrospher® 100 RP-18 and RP-18 Endcapped
              Analytics and Sample Preparation > Analytical Chromatography > Analytical HPLC > Columns for USP Specifications > L1 Octadecylsilane, Chemically Linked to Porous Silica or Ceramic Micro Particles > LiChrospher® RP-18 (5 µm)