Bead-based Assays

MultiScreenHTS filter plates have been specifically developed for compatibility with the solvents needed for combinatorial chemistry bead cleavage steps.

Overview

Specifications

Ordering Information

Go
MultiScreenHTS Filter Plates with Hydrophilic Durapore PVDF Membrane Clear Sorting & Filtering
Catalogue Numbericon Descriptionicon Device Materialicon Pore Sizeicon Sterilityicon Pack Sizeicon
MSBVN1210MultiScreenHTS BV Filter Plate, 1.2 µm, clear, non-sterile Styrene 1.2 µm Non-Sterile 10 Show Pricing & Availability
MSBVN1250MultiScreenHTS BV Filter Plate, 1.2 µm, clear, non-sterile Styrene 1.2 µm Non-Sterile 50 Show Pricing & Availability
MSBVS1210MultiScreenHTS BV Filter Plate, 1.2 µm, clear, sterile Styrene 1.2 µm Sterile 10 Show Pricing & Availability
MSDVN6510MultiScreenHTS DV Filter Plate, 0.65 µm, clear, non-sterile Styrene 0.65 µm Non-Sterile 10 Show Pricing & Availability
MSDVN6550MultiScreenHTS DV Filter Plate, 0.65 µm, clear, non-sterile Styrene 0.65 µm Non-Sterile 50 Show Pricing & Availability
MSDVN6B50MultiScreenHTS DV Filter Plate, 0.65 µm, opaque, non-sterile Barex®/TiO<sub>2</sub> 0.65 µm Non-Sterile 50 Show Pricing & Availability
MSHVN4510MultiScreenHTS HV Filter Plate, 0.45 µm, clear, non-sterile Styrene 0.45 µm Non-Sterile 10 Show Pricing & Availability
MSHVN4550MultiScreenHTS HV Filter Plate, 0.45 µm, clear, non-sterile Styrene 0.45 µm Non-Sterile 50 Show Pricing & Availability
MSHVS4510MultiScreenHTS HV Filter Plate, 0.45 µm, clear, sterile Styrene 0.45 µm Sterile 10 Show Pricing & Availability

Back To Top

MultiScreen Solvinert Filter Plates with Hydrophilic PTFE Membrane Clear Sorting & Filtering
Catalogue Numbericon Descriptionicon Device Materialicon Pore Sizeicon Pack Sizeicon
MDRLN0410MultiScreen Deep Well Solvinert, hydrophilic PTFE, 0.45 µm, clear, non-sterile Polyolefin copolymer 0.45 µm 10 Show Pricing & Availability
MSRLN0410MultiScreen Solvinert Filter Plate, hydrophilic, PTFE, 0.45 µm, clear, non-sterile Polyolefin copolymer 0.45 µm 10 Show Pricing & Availability
MSRLN0450MultiScreen Solvinert Filter Plate, hydrophilic, PTFE, 0.45 µm, clear, non-sterile Polyolefin copolymer 0.45 µm 50 Show Pricing & Availability

Back To Top

Accessories Clear Sorting & Filtering
Catalogue Numbericon Descriptionicon Pack Sizeicon
MACF09604MultiScreen Centrifuge Alignment Frame, blue, aqueous applications 4 Show Pricing & Availability
MACL09600MultiScreen Column Loader, 100µL, black, aluminum, non-sterile 1 Show Pricing & Availability
MACL09625MultiScreen Column Loader, 25µL, black, aluminum, non-sterile 1 Show Pricing & Availability
MACL09645MultiScreen Column Loader, 45µL, black, aluminum, non-sterile 1 Show Pricing & Availability
MACL09680MultiScreen Column Loader, 80µL, black, aluminum, non-sterile 1 Show Pricing & Availability
MACL0SC03Scraper for MultiScreen Column Loader 3 Show Pricing & Availability
MATAH0P00MultiScreen Sealing Tape, opaque, non-sterile 100 Show Pricing & Availability
MATAHCL00MultiScreen Sealing Tape, clear, non-sterile 100 Show Pricing & Availability
MSCPNPP0096-well V-bottom Collection Plate 100 Show Pricing & Availability
MSCPNPS0096-well Collection Plate, clear, non-sterile 100 Show Pricing & Availability
MSCPNUV4096-well MultiScreenHTS Collection Plate for UV analysis, non-sterile 40 Show Pricing & Availability
MSVMHTS00MultiScreenHTS Vacuum Manifold 1 Show Pricing & Availability
MSVMHTS0DDeep Well Collar 1 Show Pricing & Availability
WP6110060Chemical Duty Pump, 100 V/50–60 Hz 1 Show Pricing & Availability
WP6111560Chemical Duty Pump, 115 V/60 Hz 1 Show Pricing & Availability
WP6122050Chemical Duty Pump, 220 V/50 Hz 1 Show Pricing & Availability

Column Loaders are used to load chromatography media for column separations.

Back To Top

    Documentation

    References

    Reference overviewApplication
    Kinetics and isotype profile of antibody responses in rhesus macaques induced following vaccination with HPV 6, 11, 16 and 18 L1-virus-like particles formulated with or without Merck aluminum adjuvant
    Wanda Ruiz, William McClements, Kathrin Jansen, and Mark esser
    Journal of Immune Based Therapies and Vaccines 2005, 3:2  2005

    Bead-based Assays
    Use of ADME screening to conserve resources in drug discovery and development
    Weiss, A. and Joseph Machamer
    American Biotechnology Laboratory, January 2004: 16-17  2004

    Screening for pharma gold: Researchers are using membrane technologies for high-throughput ADME analysis
    Lynch, John,Modern Drug Discovery, January 2004: 27-28
    Modern Drug Discovery, January 2004: 27-28  2004

    Scintillation proximity assay of inositol phosphates in cell extracts: High-throughput measurement of G-protein-coupled receptor activation
    Philip E. Brandish, Lorraine A. Hill, Wei Zheng and Edward M. Scolnick
    Analytical Biochemistry 313 (2): 311-318  2003

    Bead-based Assays
    Functional roles of conserved transmembrane prolines in the human VPAC1 receptor.
    Sanne Moller Knudsen, Jeppe Wegener Tams and Jan Fahrenkrug; Journal of Biochemical and Biophysical Methods 40 (3): 113-117
    Journal of Biochemical and Biophysical Methods 40 (3): 113-117  2001

    Bead-based Assays
    A high-throughput assay for rat liver Golgi and Saccharomyces cerevisiae-expressed murine CMP-N-acetylneuraminic acid transport proteins
    Tiralongo J; Abo S; Danylec B; Gerardy Schahn R; vonItzstein M
    Analytical Biochemistry 2000 , v285, n1, p21-32  2000

    Bead-based Assays
    Designing new metal affinity peptides by random mutagenesis of a natural metal-binding site.
    Markus M. Enzelberger, Stefan Minning and Rolf D. Schmid
    Journal of Chromatography A 898 (1): 83-94  2000

    Bead-based Assays
    Quantification of telomerase activity by direct scintillation counting.
    Sonja Kazmer, Keh-Ming Pan and Lyubomir Vassilev
    Journal of Biochemical and Biophysical Methods 40 (3): 113-117  1999

    Bead-based Assays
    Evaluation of Islet Cell Antigen (ICA)512/IA-2 Autoantibody Radioassays Using Overlapping ICA512/IA-2 Constructs
    Kawaski, E., Yu, L., Gianani, R., Verge, C.F., Babu, S., Bonifacio, E., Eisenbarth, G.S.
    Journal of Clinical Endocrinology & Metabolism 82:2, 375-380  1997

    Bead-based Assays
    Microplate Chromatography Assay for Acety1-CoA: Lysoplatelet-Activating Factor Acetyltransferase1
    Kume, K., Waga, I., Shimizu, T.
    Analytical Biochemistry 246:, 118-122  1997

    Bead-based Assays

    FAQ

    QuestionAnswer
    What is the well depth and maximum volume capacity of a MultiScreen plate?The well depth of a 96 well MultiScreen plate is 1.245 cm. The well depth for a 384 well MultiScreen plate is 1.2 cm. The maximum working volume of a 96 well plate is 300 ul. The maximum working volume for a 384 well plate is 100 ul.

    User Guides

    Title
    MultiScreen® High Volume Filter Plate and Accessories