109986 | Cobalt standard

109986
Price could not be retrieved
Minimum Quantity needs to be mulitiple of
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Limited AvailabilityLimited Availability
In Stock 
Discontinued
Limited Quantities Available
Availability to be confirmed
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      View Pricing & Availability
      Click To Print This Page
      Download Product Safety Card

      Overview

      Replacement Information

      Key Spec Table

      Pricing & Availability

      Catalogue NumberAvailability Packaging Qty/Pack Price Quantity
      1099860001
      Retrieving availability...
      Limited AvailabilityLimited Availability
      In Stock 
      Discontinued
      Limited Quantities Available
      Availability to be confirmed
        Remaining : Will advise
          Remaining : Will advise
          Will advise
          Contact Customer Service

          Plastic ampoule 1 amp
          Retrieving price...
          Price could not be retrieved
          Minimum Quantity needs to be mulitiple of
          Upon Order Completion More Information
          You Saved ()
           
          Request Pricing
          Description
          Catalogue Number109986
          References
          Product Information
          HS Code2827 39 30
          Applications
          Biological Information
          Physicochemical Information
          Density1.04 g/cm3 (20 °C)
          pH value4.8 (H₂O, 20 °C)
          Dimensions
          Materials Information
          Toxicological Information
          Safety Information according to GHS
          Hazard Pictogram(s)

          Hazard Statement(s)H360F: May damage fertility.
          H317: May cause an allergic skin reaction.
          H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.
          H341: Suspected of causing genetic defects.
          H411: Toxic to aquatic life with long lasting effects.
          H350i: May cause cancer by inhalation.
          Precautionary Statement(s)P201: Obtain special instructions before use.
          P273: Avoid release to the environment.
          P280: Wear protective gloves.
          P302 + P352: IF ON SKIN: Wash with plenty of soap and water.
          P304 + P340: IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
          P342 + P311: If experiencing respiratory symptoms: Call a POISON CENTER/doctor.
          Signal WordDanger
          Storage class6.1 D Non combustible, acute toxicity cat. 3 / toxic or substances with chronic effects
          WGKWGK 3 highly water endangering
          Disposal15
          Heavy metal-containing solutions and solids: container E. Stir Raney nickel (also: Urushibara nickel) in the form of an aqueous suspension into hydrochloric acid (Cat. No. 100312) until dissolved (container E). Neither Raney nickel itself nor any filter residues should be allowed to dry out, otherwise they will spontaneously ignite in air. In this context, heavy metal means any compound of antimony, arsenic, cadmium, chromium(VI), copper, lead, nickel and tin, as well as these subtances in metallic form, if they are classified as hazardous (acc. to AbfallverzeichnisV - Waste Catalogue Ordinance, Appendix 3). Other heavy metals should be collected separately.
          Safety Information
          Hazard Symbols Dangerous for the environment
          Toxic
          Categories of dangercarcinogenic, toxic for reproduction, sensitizing, dangerous for the environment, mutagenic
          R PhraseR 49-60-42/43-51/53-68
          May cause cancer by inhalation.May impair fertility.May cause sensitisation by inhalation and skin contact.Toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment.Possible risk of irreversible effects.
          S PhraseS 53-23-36/37-45-61
          Avoid exposure - obtain special instructions before use.Do not breathe vapour.Wear suitable protective clothing and gloves.In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible).Avoid release to the environment. Refer to special instructions/ Safety data sheets.
          Product Usage Statements
          Storage and Shipping Information
          StorageStorage temperature: no restrictions.
          Packaging Information
          Transport Information
          Declaration (railroad and road) ADR, RIDUN 3082 , 9, III
          Declaration (transport by air) IATA-DGRUN 3082 , 9, III
          Declaration (transport by sea) IMDG-CodeUN 3082 , 9, III, Marine Pollutant: P
          Supplemental Information
          Specifications
          content (Co)1000 mg / Ampoule
          Determination method: Complexometric titration.
          (traceable to NIST - SRM 682)
          Accuracy of the method: +/- 2 mg

          Related Products & Applications

          Related Products

          Catalogue Number Description  
          119785 Cobalt standard solution Show Pricing & Availability

          Accessories (Primary)

          Catalogue Number Description  
          116755 Cesium chloride-lanthanum chloride buffersolution Show Pricing & Availability

          Related Products By: Brand Facete

          Categories

          Reagents, Chemicals and Labware > Inorganic Reagents > Instrumental Inorganic Analysis > Certipur® Standards, Reference Materials and Buffers > Certipur® Reference Materials for AAS and ICP > Titrisol® Standards
          Analytics and Sample Preparation > Reference Materials > Certipur® Reference Materials for AAS and ICP > Standards Titrisol®
          Analytics and Sample Preparation > Spectroscopy > Certipur® Reference Materials for AAS and ICP > Titrisol® Standards