A part of Merck

152022 | Chromolith® HighResolution RP-18 endcapped 100-4.6 HPLC column

152022
Price could not be retrieved
Minimum Quantity needs to be mulitiple of
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Limited AvailabilityLimited Availability
In Stock 
Discontinued
Limited Quantities Available
Availability to be confirmed
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      View Pricing & Availability
      Click To Print This Page

      Overview

      Replacement Information

      Key Spec Table

      Pricing & Availability

      Catalogue NumberAvailability Packaging Qty/Pack Price Quantity
      1520220001
      Retrieving availability...
      Limited AvailabilityLimited Availability
      In Stock 
      Discontinued
      Limited Quantities Available
      Availability to be confirmed
        Remaining : Will advise
          Remaining : Will advise
          Will advise
          Contact Customer Service

          Fibre case 1 unit
          Retrieving price...
          Price could not be retrieved
          Minimum Quantity needs to be mulitiple of
          Upon Order Completion More Information
          You Saved ()
           
          Request Pricing
          Description
          Catalogue Number152022
          OverviewAll Chromolith® HighResolution columns are made of monolithic silica with a characteristic bimodal pore structure. Chromolith® 4.6 mm columns have macropores with 1.15 µm diameter, giving a column efficiency exceeding 140,000 plates/meter. The mesopores are 15 nm (150 Å), the surface modification is octadecylsilan with full end-capping.
          References
          Product Information
          HS Code9027 90 50
          Applications
          Biological Information
          Physicochemical Information
          Dimensions
          Materials Information
          Toxicological Information
          Safety Information according to GHS
          Storage class10 - 13 Other liquids and solids
          Disposal32
          Chromatographic residues: Aggressive, explosive (e.g. peroxides) or toxic substances in chromatographic layers or sorbents must be eliminated using suitable methods (washing out, elution) prior to disposal. The solvents used for elution can in many cases be reutilized. Larger quantities of sorbents (e.g. from columns) should be freed from solvents (filtration, drying) and packed into rip-resistant plastic sachets; container I. TLC carrier materials and columns should be disposed of together with the corresponding waste materials (aluminium, glass, plastic); container K.
          Safety Information
          Product Usage Statements
          Storage and Shipping Information
          StorageStorage temperature: no restrictions.
          Packaging Information
          Transport Information
          Supplemental Information
          Specifications
          Appearancepasses test
          Pressure40 - 70 bar
          stability testingpasses test
          Performance (anthracene)
          Theoretical Plates (N/m) (Anthracene)≥ 140000
          Capacity factor (Anthracene)3.9 - 4.6
          Tailing (USP)0.90 - 1.30 %
          Selectivity
          separation factor (anthracene/progesterone)1.95 - 2.35

          Documentation

          MSDS

          Title

          Safety Data Sheet (SDS) 

          Certificates of Analysis

          Product Number PackagingSpecificationLot Number
          1520220001 Fibre casePDF Specification Document

          Brochure

          Title
          For a perfect start - Chromaster
          Pharmacopoeia Monograph Methods HPLC and UHPLC columns for Regulated Drug Analysis

          Technical Info

          Title
          Acetaminophen, Aspirin and Caffeine (USP) - Excedrin Tablet Dissolution
          Amlodipine Besylate and Related Substances From Particulate to Monolithic Column
          Atenolol (USP) - Tablets
          Atorvastatin MM
          Atovaquone Oral Suspension (USP)
          Cetirizine Hydrochloride (USP) - Tablets
          Chloropheniramine Maleate MM
          Chloropheniramine Maleate Related Substances - Chromolith® HighResolution RP-18 endcapped
          Complete Monograph Methods - Solutions for regulated Pharmaceutical Instrumental Analysis Methods with HPLC, FTIR, KF, AAS and ICP 2015 -1
          Complete solutions for Dissolution Testing - Monograph methods for Tablets and Capsules 2015-2
          Constituents and Additives
          Constituents and Additives
          Constituents and Additives
          Constituents and Additives
          Dofetilide and Related Substances (USP)
          Esomeprazole (USP)
          Ethacrynic Acid MM
          Fexofenadine Hydrochloride (USP) - Tablets
          Folic Acid MM
          Folic Acid Tablets (USP)
          Food Safety and Food Quality Control - Beat your own record!
          Honey Analysis
          Ibuprofen and Codeine MM
          Ivermectin MM
          Letrozole Tablets (USP)
          Levetiracetam (USP) - Tablets
          Levetiracetam and Caffeine MM
          Paliperidone and Related Substances - Chromolith® HighResolution RP-18 endcapped
          Panax Notoginseng
          Pharmaceutical impurity profiling Application guide
          Radix Puerariae
          Ranitidine Hydrochloride Tablets (USP)
          Solutions for Milk Testing Tartaric- Malic- Citric- Succinic Acid
          Traditional Eastern Medication Application guide
          Vitamin E MM
          Vitamins

          Related Products & Applications

          Related Products By: Application Facete

          Categories

          Analytics and Sample Preparation > Analytical Chromatography > Analytical HPLC > Columns for USP Specifications > L1 Octadecylsilane, Chemically Linked to Porous Silica or Ceramic Micro Particles > Chromolith® RP-18 Endcapped
          Analytics and Sample Preparation > Analytical Chromatography > Analytical HPLC > Chromolith® HPLC Columns > Chromolith® Monolithic HPLC Columns > Chromolith® RP-18 Endcapped Monolithic Silica HPLC Columns > Chromolith® RP-18e HighResolution HPLC Columns