Skip to Content
Merck
  • Occurrence of 13 volatile organic compounds in foods from the Canadian total diet study.

Occurrence of 13 volatile organic compounds in foods from the Canadian total diet study.

Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment (2016-01-06)
Xu-Liang Cao, Melissa Sparling, Robert Dabeka
ABSTRACT

Volatile organic compounds (VOCs) are ubiquitous in the environment due to evaporation and incomplete combustion of fuels, use of consumer and personal care products, etc. and they can accumulate in foods. Some VOCs in foods can also be formed during food processing and preparation and migrate from food packaging. In this pilot study, a GC-MS method based on headspace solid-phase microextraction (SPME) was validated and used to analyse selected individual foods which can be consumed directly and 153 different total diet composite food samples for 13 VOCs. Vinyl chloride was not detected in any of the 153 composite food samples, while the other 12 VOCs were detected at various frequencies, with m-xylene being the most frequently detected (in 151 of the 153 samples), followed by toluene (145), 1,3,5-trimethylbenzene (140), ethylbenzene (139), styrene (133), 1,2,4-trimethylbenzene (122), benzene (96), p-dichlorobenzene (95), n-butylbenzene (55), chloroform (45), naphthalene (45) and trichloroethylene (31). Concentrations of the 12 VOCs in most of the food composite samples were low, with the 90th percentiles from 1.6 ng g(-1) for n-butylbenzene to 20 ng g(-1) for toluene. However, some VOCs were detected at higher levels with maxima, for example, of 948 ng g(-1) for m-xylene and 320 ng g(-1) for ethylbenzene in chewing gum, 207 ng g(-1) for styrene and 157 ng g(-1) for toluene in herbs and spices. VOCs were detected at higher levels in most of the individual food items than their corresponding composite samples, for example, the average chloroform concentration in the individual canned soft drinks was 20 ng g(-1) compared with 3.0 ng g(-1) in their composite, and the average toluene concentration in the individual canned citrus juice was 96 ng g(-1) compared with 0.68 ng g(-1) in their composite. Thus, for determination of VOCs in foods which can be consumed directly, their individual food items should be analysed whenever possible for accurate exposure assessment.

MATERIALS
Product Number
Brand
Product Description

Supelco
SPME Fiber Assembly, 60 μm PEG, Metal Alloy (1 cm), needle size 23 ga, Manual Holder, pk of 3, purple hub
Supelco
SPME Fiber Assembly, 60 μm PEG, Metal Alloy (1 cm), needle size 23 ga, Autosampler, pk of 3, purple hub
Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, pink hub
Supelco
SPME Fiber Assembly, 85 μm CAR/PDMS, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, light blue hub
Supelco
SPME Fiber Assembly, 50/30µm DVB/CAR/PDMS, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, plain gray hub
Supelco
SPME Fiber Assembly, 85 μm Polyacrylate, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, white hub
Supelco
SPME Fiber Assembly, 100 μm PDMS, Fused Silica (1 cm), needle size 23 ga, Manual Holder, pk of 3, red hub
Supelco
SPME Fiber Assembly, 50/30µm DVB/CAR/PDMS, StableFlex (1cm), needle size 24 ga, Manual Holder, pk of 3, plain gray hub
Supelco
SPME Fiber Assembly, 85 μm CAR/PDMS, StableFlex (1 cm), needle size 24 ga, Autosampler, pk of 3, light blue hub
Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, blue hub
Supelco
SPME Sampling Stand, for use with 15 mL vials
Supelco
SPME Fiber Assembly, 30 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, yellow hub
Supelco
SPME Fiber Assembly, 85 μm CAR/PDMS, StableFlex (1 cm), needle size 24 ga, Manual Holder, pk of 3, light blue hub
Supelco
SPME Fiber Assembly, 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, black hub
Supelco
SPME Fiber Assembly, 30 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, yellow hub
Supelco
SPME Fiber Assembly, 100 μm PDMS, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, red hub
Supelco
SPME Sampling Stand, for use with 4 mL vials
Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, blue hub
Supelco
SPME Portable Field Sampler, coating PDMS/DVB
Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, blue hub
Supelco
SPME Fiber Assembly, 7 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, green hub
Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, StableFlex (1 cm), needle size 24 ga, Manual Holder, pk of 3, pink hub
Supelco
SPME Fiber Assembly, 7 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, green hub
Supelco
SPME Fiber Assembly, 65 μm PDMS/DVB, StableFlex (1 cm), needle size 24 ga, Autosampler, pk of 3, pink hub
Supelco
SPME Fiber Assembly, 50/30µm DVB/CAR/PDMS, StableFlex (2cm), needle size 24 ga, Autosampler, pk of 3, notched gray hub
Supelco
SPME Fiber Assembly, 100 μm PDMS, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, red hub
Supelco
SPME Fiber Assembly, 85 μm Polyacrylate, Fused Silica (1 cm), needle size 24 ga, Manual Holder, pk of 3, white hub
Supelco
SPME Fiber Assembly, 85 μm Polyacrylate, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, white hub
Supelco
SPME Portable Field Sampler, coating CAR/PDMS
Supelco
SPME Fiber Assembly, 50/30µm DVB/CAR/PDMS, StableFlex (2cm), needle size 23 ga, Autosampler, pk of 3, notched gray hub