Amicon® Ultra-15 Centrifugal Filter Units
 
Provide both ultra-fast spin times and ultra-high recoveries 
 More
Provide both ultra-fast spin times and ultra-high recoveries  Less
 
More>>
Less<<

Recommended Products
Overview
Specifications
Ordering Information
Documentation
References
| Reference overview | Application | 
|---|---|
| Simultaneous reduction and alkylation of protein disulfides in a centrifugal ultrafiltration device prior to two-dimensional gel electrophoresis. Smejkal GB, Li C, Robinson MH, Lazarev AV, Lawrence NP, Chernokalskaya E. J Proteome Res. 2006 Apr;5(4):983-7. 2006 | Protein Concentration | 
| Ultrafiltration for proteomic sample preparation E. Chernokalskaya, S. Gutierrez, A.M. Pit, J. T. Leonard Electrophoresis, 25: 2461-2468 2004 | Sample Prep | 
FAQ
| Question | Answer | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Amicon Ultra units are offered in what volumes? | Amicon Ultra units are available in 0.5 mL, 4mL & 15ml volumes. | ||||||||||||
| What is the recommended rotor for Amicon Ultra units? | Any rotor capable of accommodating 22.7 cm in diameter and 124 mm length centrifuge tubes for the Amicon Ultra-4 and 35 mm in diameter and 121 mm in length for the Amicon Ultra-15 can be used for Amicon Ultra units. | ||||||||||||
| How should I select the appropriate Molecular Weight Cutoff (MWCO) for Amicon Ultra? | Select a Molecular Weight Cutoff that is 2x smaller that the Molecular Weight (MW) of the solute of interest. | ||||||||||||
| Which membranes are available in Amicon Ultra units? | Amicon Ultra units are only available with Ultracel regenerated cellulose material. This high recovery/low binding membrane is offered in 3,000, 10,000, 30,000, 50,000 & 100,000 MWCO. | ||||||||||||
| Can the Amicon Ultra be spun to dryness? | No, the Amicon Ultra has a built in deadstop. | ||||||||||||
| Can the Amicon Ultra be used with nucleic acids? | Yes, Amicon Ultra units have been evaluated for use with Genomic and PCR fragments. The 30 kDa MWCO provides the best balance between recovery and spin time. Protocols related to Genomic and PCR fragments can be found in the user guide. | ||||||||||||
| What is the maximum sample volume for Amicon Ultra? | 
 | ||||||||||||
| What is the maximum centrifugal force I can spin Amicon Ultra-4 & Amicon Ultra-15? | 
 | ||||||||||||
| What is the chemical compatibility of Amicon Ultra? | Amicon Ultra units are intended for use with biological fluids and aqueous solutions. Please refer to the user guide, catalogue, or contact Technical Support. | ||||||||||||
| Can Amicon Ultra units be sterilized with ethanol? | Amicon Ultra is compatible with 70% Ethanol, but we have not done any studies to test for sterilization. | 
Related Products & Applications
Related Products By: Application Facete
| Protein Purification | 
| Dialysis and Filtration | 
Related Products By: Brand Facete
| Ultracel® | 
| Amicon® | 
Categories
| Life Science Research > Protein Sample Preparation > Protein Concentration & Dialysis > Sample Prep Centrifugal Filter Units | 
- High recovery Ultracel regenerated cellulose membrane in a range of molecular weight cut-offs 
- High retentate recovery of >90% 
- Vertical membrane reduces concentration polarization for ultra-fast spin times (as fast as 10–15 minutes) 
- Heat-sealed membrane minimizes downstream extractables 
- 100% integrity tested for reliable performance 
- Convenient sample monitoring with translucent housing and volume gradations 
- Direct pipettor sample access eliminates processing step to recover concentrate 
- High concentration factors of 80–100X
Applications
- Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms 
- Purification of macromolecular components found in tissue culture extracts or cell lysates and protein removal prior to HPLS 
- Concentration of dilute or pre-purified proteins from column eluents 
- Desalting, buffer exchange and protein dialysis
Not sure if you found the right Amicon® for your application?
» Search with our new Amicon Ultra Selector tool.
Typical Spin Times to Filtrate Volume
 
                                                            Spin conditions: 4000 xg swinging bucket rotor at 25°C, 15 mL sample. 
3K, 10K: Cytochrome c (0.25 mg/mL); 30K, 50K: BSA (1 mg/mL); 100K: IgG (1 mg/mL).
Typical Protein Recovery
| Membrane NMWL, kDa | Protein Solute | Protein Retentate Volume, mL | Protein Retentate Recovery, % | 
| 3 | Cytochrome c, 12.4 kDa (0.25 mg/mL) | 0.294 | 97.5 | 
| 10 | Cytochrome c, 12.4 kDa (0.25 mg/mL) | 0.24 | 93.03 | 
| 30 | BSA, 67 kDa (1 mg/mL) | 0.30 | 97.94 | 
| 50 | BSA, 67 kDa (1 mg/mL) | 0.17 | 93.32 | 
| 100 | IgG, 156 kDa (1 mg/mL) | 0.28 | 89.03 | 
| 15 mL starting volume in swinging bucket rotor at 4000 x g at 25 °C. Spin times: 3K (40 min); 10K and 100K (20 min); 30K (10 min); 50K (15 min). | |||
| Volumes | |
| Maximum Initial Sample Volume, mL* | 15 mL | 
| Typical Final Concentrate Volume, µL | 200 µL | 
| Centrifugal Force | |
| Materials | |
| Membrane | Ultracel regenerated cellulose | 
| Device | Housing: Styrene/butadiene Tube: Polypropylene Cap and liner: Polyethylene | 
| Dimensions | |
| Active Membrane Area | 7.6 cm² | 
| Diameter | 2.97 cm | 
| Filtrate tube or vial (centrifuge tube) | |
| Length | 12.1 cm (4.807 in.) | 
| Filter unit | |
| Diameter, mm | 29.6 | 
| Length, mm | 72.0 | 
| *Except for 35° fixed angle rotor: 12 mL | |
Amicon Ultra-15 Centrifugal Filter Unit with Ultracel-10 membrane is CE marked.

 


 
  

 
 
 