Our broad portfolio consists of multiplex panels that allow you to choose, within the panel, analytes that best meet your needs. On a separate tab you can choose the premixed cytokine format or a single plex kit.
Cell Signaling Kits & MAPmates™
Choose fixed kits that allow you to explore entire pathways or processes. Or design your own kits by choosing single plex MAPmates™, following the provided guidelines.
The following MAPmates™ should not be plexed together:
-MAPmates™ that require a different assay buffer
-Phospho-specific and total MAPmate™ pairs, e.g. total GSK3β and GSK3β (Ser 9)
-PanTyr and site-specific MAPmates™, e.g. Phospho-EGF Receptor and phospho-STAT1 (Tyr701)
-More than 1 phospho-MAPmate™ for a single target (Akt, STAT3)
-GAPDH and β-Tubulin cannot be plexed with kits or MAPmates™ containing panTyr
.
Catalogue Number
Ordering Description
Qty/Pack
List
This item has been added to favorites.
Select A Species, Panel Type, Kit or Sample Type
To begin designing your MILLIPLEX® MAP kit select a species, a panel type or kit of interest.
Custom Premix Selecting "Custom Premix" option means that all of the beads you have chosen will be premixed in manufacturing before the kit is sent to you.
Catalogue Number
Ordering Description
Qty/Pack
List
This item has been added to favorites.
Species
Panel Type
Selected Kit
Qty
Catalogue Number
Ordering Description
Qty/Pack
List Price
96-Well Plate
Qty
Catalogue Number
Ordering Description
Qty/Pack
List Price
Add Additional Reagents (Buffer and Detection Kit is required for use with MAPmates)
Qty
Catalogue Number
Ordering Description
Qty/Pack
List Price
48-602MAG
Buffer Detection Kit for Magnetic Beads
1 Kit
Space Saver Option Customers purchasing multiple kits may choose to save storage space by eliminating the kit packaging and receiving their multiplex assay components in plastic bags for more compact storage.
This item has been added to favorites.
The Product Has Been Added To Your Cart
You can now customize another kit, choose a premixed kit, check out or close the ordering tool.
Attention: We have moved. Merck Millipore products are no longer available for purchase on MerckMillipore.com.Learn More
Millipore filters were among the first to be used for ambient air monitoring, as early as the 1970s. Particulates and contaminants in the air affect human capital, the most precious natural resource our planet supports. Recognizing the need to protect this resource, industries, governments, and associated regulatory agencies around the world monitor ambient air. Air monitoring methods have been developed to detect and quantify diverse contaminants and particulates, including PM2.5, PM10, sulfur dioxide, fluorides, heavy metals, and radioactive particles. Many of these methods involve gravimetric analysis and monitoring systems that use membrane filter discs and filter holders.
Millipore filters, now supplied by Merck, are used in regulated ambient air monitoring methods. Use the selector wizard below to determine the correct filter to use for your air monitoring needs, or follow these links to the application of your choice:
Nuclear power is relatively clean and renewable, and through radiation monitoring, can be a safe source of energy for the planet. Although there are many naturally occurring radioisotopes that make up water, air, soil and organisms, the challenge in radiation monitoring is to detect the “non-natural” radiation signal above the naturally occurring background radiation levels. To support efficient, convenient radiation monitoring, Merck has developed a special Fluoropore™ membrane filter designed for alpha particle collection in continuous air monitors.
The Fluoropore™ filter for alpha particle monitoring provides:
Improved data collection: Unlike fibrous filter media that trap particles in their matrix, Fluoropore™ (hydrophobic PTFE) membranes collect particles on their surface. This surface collection provides better detection efficiencies and improved resolution.
Choice of pore sizes: Fluoropore™ membranes are available in 3 and 5 μm pore sizes. The smaller pore size provides high resolution. The larger pore size has very low pressure drop and greater throughput capacity, which minimizes the number of filter changeouts.
Contrasting backing material: The 5 μm Fluoropore™ membrane is bonded to a contrasting backing made from high density polyethylene fiber. The contrast between the top and bottom of the filter prevents incorrect installation in sampling devices. The backing also reduces the electrostatic charge of the filters and makes them easier to handle.
Merck provides membranes with low ash content as well as IC-compatible syringe filters to prepare your reconstituted samples prior to ion chromatography.
Recently, the focus has been on PM2.5 levels, which have been linked to respiratory problems, cancer, and aging-related disorders such as Alzheimer’s disease and bone damage. Major regulatory agencies have now issued guidance and methods for monitoring PM2.5, as outlined in the table below:
Regulated Methods
Annual limit
Filter diameter
Filter material
Merck Catalog No.
US, Japan US EPA 40 CFR part 50
≤35 µg/m3
46.2 mm ±0.25 mm
PTFE with a ring (For reference / manual method)
PM2547050
Glass fiber roll for automated / equivalent methods
Merck Ensures That Membrane Discs Match Regulatory Specifications.
Certification documents for each product will be shipped in each box. Detailed test results can be obtained by contacting Merck Technical Support.
Test
Specification*
AP20 Glass Fiber
AQFA Quartz Fiber
PTFE Filter with Ring
Temperature Stability
≤20 µg/filter disc
4
16
-4.0
Loose Particle Test
≤20 µg/filter disc
22
39
1.0
Particle Retention
≥99.7%
>99.9%
>99.9%
>99.9%
Pressure Drop
≤3 kPa @ 0.45 m/s air flow rate
~1 kPa
~1 kPa
0.65 kPa
Additional tests performed for certified PTFE filters as per U.S. EPA guidelines**
Alkalinity
≤25 µeq/g filter
0.3
XRF Analysis
Low background signal
Meets
*(As Per Chinese PM2.5 Sampling Standard) **Certification documents for each product, stating that all tests were carried out according to United States Environmental Protection Agency (EPA) requirements, will be shipped in each box.
PM 2.5 Membrane Characteristics and Detailed Test Specifications
Airborne particles in the range of 10 µm in size have also been linked to negative effects on our breathing and respiratory systems. Merck provides filter media designed for PM10 testing that complies with government-established standards.