Skip to Content
Merck
  • Detection of potato brown rot and ring rot by electronic nose: from laboratory to real scale.

Detection of potato brown rot and ring rot by electronic nose: from laboratory to real scale.

Talanta (2014-08-17)
E Biondi, S Blasioli, A Galeone, F Spinelli, A Cellini, C Lucchese, I Braschi
ABSTRACT

A commercial electronic nose (e-nose) equipped with a metal oxide sensor array was trained to recognize volatile compounds emitted by potatoes experimentally infected with Ralstonia solanacearum or Clavibacter michiganensis subsp. sepedonicus, which are bacterial agents of potato brown and ring rot, respectively. Two sampling procedures for volatile compounds were tested on pooled tubers sealed in 0.5-1 L jars at room temperature (laboratory conditions): an enrichment unit containing different adsorbent materials (namely, Tenax(®) TA, Carbotrap, Tenax(®) GR, and Carboxen 569) directly coupled with the e-nose (active sampling) and a Radiello(™) cartridge (passive sampling) containing a generic Carbograph fiber. Tenax(®) TA resulted the most suitable adsorbent material for active sampling. Linear discriminant analysis (LDA) correctly classified 57.4 and 81.3% total samples as healthy or diseased, when using active and passive sampling, respectively. These results suggested the use of passive sampling to discriminate healthy from diseased tubers under intermediate and real scale conditions. 80 and 90% total samples were correctly classified by LDA under intermediate (100 tubers stored at 4°C in net bag passively sampled) and real scale conditions (tubers stored at 4°C in 1.25 t bags passively sampled). Principal component analysis (PCA) of sensorial analysis data under laboratory conditions highlighted a strict relationship between the disease severity and the responses of the e-nose sensors, whose sensitivity threshold was linked to the presence of at least one tuber per sample showing medium disease symptoms. At intermediate and real scale conditions, data distribution agreed with disease incidence (percentage of diseased tubers), owing to the low storage temperature and volatile compounds unconfinement conditions adopted.

MATERIALS
Product Number
Brand
Product Description

Supelco
radiello BTEX Calibration Kit (Thermal Desorption)
radiello Clips, suspending Radiello triangular support plate, pk of 20
radiello BTEX/VOC Starter Kit, CS2 Desorption
radiello Diffusive Bodies, white, configured for general use, pk of 20
radiello On-Field Thermometer, Includes one standard Radiello vertical adapter (RAD122) for each thermometer, configured for standard use, pk of 3
radiello BTEX/VOC Starter Kit, Thermal Desorption
radiello Diffusive Bodies, blue, configured for sampling light sensitive compounds, pk of 20
Supelco
radiello Methylene Blue Calibration Standard for H2S (Hydrogen Sulfide), pkg of 100 mL
radiello On-Field Thermometer, Reader, pk of 1
radiello 1,3-Butadiene Starter Kit, Thermal Desorption, pkg of 1 kit (2 RAD141 adsorbing cartridges and barcode labels, 1 RAD1202 yellow diffusive body, 1 RAD121 triangular support plate, 1 instruction sheet)
Supelco
Carboxen® Adsorbent, matrix Carboxen® 572, 20-45 mesh, bottle of 10 g
Supelco
radiello BTEX Calibration Kit (CS2 Desorption)
radiello Empty Storage Tubes, polypropylene (with stopper), volume 12 mL, pk of 100
radiello Diffusive Bodies, permeative, configured for anaesthetic gases and vapors, pk of 20
radiello Filtration Kit, pk of 20
Supelco
radiello Aldehyde Calibration Standard, 50 μg/mL each component in acetonitrile, pkg of 10 mL
Supelco
Carbotrap® 349, glass TD tube, fritted, O.D. × I.D. × L 6 mm × 4 mm × 7 in., preconditioned, pkg of 1 ea
Supelco
SPME Fiber Assembly, 85 μm CAR/PDMS, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, light blue hub
Supelco
SPME Fiber Assembly, 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 23 ga, Autosampler, pk of 3, black hub
Supelco
Carbotrap® 300, stainless steel TD tube, O.D. × I.D. × L 6 mm × 4 mm × 7 in., preconditioned, pkg of 1 ea
Supelco
Carboxen® Adsorbent, matrix Carboxen® 1000, 40-60 mesh, bottle of 50 g
Supelco
SPME Fiber Assembly, 50/30µm DVB/CAR/PDMS, StableFlex (2cm), needle size 24 ga, Autosampler, pk of 3, notched gray hub
Supelco
SPME Fiber Assembly, 85 μm CAR/PDMS, StableFlex (1 cm), needle size 24 ga, Autosampler, pk of 3, light blue hub
Supelco
SPME Fiber Assembly, 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 24 ga, Autosampler, pk of 3, black hub
Supelco
Carbotrap® 300, glass TD tube, fritted, O.D. × I.D. × L 6 mm × 4 mm × 7 in., preconditioned, pkg of 1 ea
Supelco
SPME Fiber Assembly, 75 μm CAR/PDMS, Fused Silica (1 cm), needle size 23 ga, Manual Holder, pk of 3, black hub
Supelco
SPME Fiber Assembly, 85 μm CAR/PDMS, StableFlex (1 cm), needle size 24 ga, Manual Holder, pk of 3, light blue hub
Supelco
SPME Fiber Assembly, 50/30µm DVB/CAR/PDMS, StableFlex (1 cm), needle size 24 ga, Autosampler, pk of 3, plain gray hub
Supelco
Carboxen® Adsorbent, matrix Carboxen® 564, 20-45 mesh, pack of 144 × 290 mg
Supelco
Carboxen®-1006 PLOT Capillary GC Column, L × I.D. 30 m × 0.32 mm, average thickness 15 μm