Skip to Content
Merck
  • Development and validation of an LC-MS/MS method for determination of p-phenylenediamine and its metabolites in blood samples.

Development and validation of an LC-MS/MS method for determination of p-phenylenediamine and its metabolites in blood samples.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2015-06-16)
Khaled M Mohamed, Duncan Cromarty, Vanessa Steenkamp
ABSTRACT

In some developing countries, p-phenylenediamine (PPD) is used in combination with Henna as hair dye or skin decoration. A sensitive LC-MS/MS method was developed and validated for the simultaneous determination of p-phenylenediamine (PPD) and its metabolites N-acetyl-p-phenylenediamine (MAPPD) and N,N-diacetyl-p-phenylenediamine (DAPPD) in human blood. Acetanilide was used as an internal standard (IS). The LC-MS/MS was operated under multiple reaction-monitoring mode using the electrospray positive ionization technique. The transition ions m/z 109→92, m/z 151→92, m/z 193→92, and m/z 136→77 were selected for the quantification of PPD, MAPPD, DAPPD, and IS, respectively. The linear range was 10-2000ng/mL for all the compounds. The absolute recoveries were 51.94, 56.20 and 54.88% for PPD, MAPPD and DAPPD, respectively. Intra- and inter-assay imprecision were lower than 14% (RSD), and the bias of the assay was lower than 15% for all the compounds. The stability studies demonstrated that critical degradation for PPD in blood samples and autosampler occurred after 6h, while MAPPD and DAPPD were stable in blood samples and the autosampler up to 48h and 24h, respectively. This newly developed method allows for the detection of PPD and its metabolites in blood samples in the clinical and forensic setting.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Acetanilide, zone-refined, purified by sublimation, ≥99.95%
Sigma-Aldrich
Acetonitrile solution, contains 10.0% acetone, 0.05% formic acid, 40.0% 2-propanol
Sigma-Aldrich
Ammonium acetate solution, 50 % (w/v)
Sigma-Aldrich
tert-Butyl methyl ether, SAJ special grade, ≥99.0%
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (v/v) trifluoroacetic acid
Sigma-Aldrich
Ammonium acetate solution, Molecular Biology, 7.5 M
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (w/v) ammonium formate, 5 % (v/v) water, 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
tert-Butyl methyl ether, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Supelco
tert-Butyl methyl ether, HPLC grade, suitable for HPLC, 99.8%
Sigma-Aldrich
Ammonium acetate, Molecular Biology, ≥98%
Sigma-Aldrich
Ammonium acetate, 99.999% trace metals basis
Sigma-Aldrich
Ammonium acetate, BioXtra, ≥98%
Sigma-Aldrich
Ammonium acetate, reagent grade, ≥98%
Sigma-Aldrich
Acetanilide, purified by sublimation, ≥99.9%
Sigma-Aldrich
Ammonium formate, ≥99.995% trace metals basis
Sigma-Aldrich
Ammonium formate, SAJ first grade, ≥95.0%
Sigma-Aldrich
tert-Butyl methyl ether, anhydrous, 99.8%
Sigma-Aldrich
Acetanilide, 99%
Supelco
Ammonium formate solution, 10 mM in H2O, suitable for HPLC
Sigma-Aldrich
Acetonitrile, JIS special grade, ≥99.5%
Sigma-Aldrich
Dichloromethane, SAJ first grade, ≥99.0%
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for HPLC
Sigma-Aldrich
Acetonitrile, SAJ first grade, ≥99.0%
Sigma-Aldrich
Acetonitrile, suitable for residue analysis, JIS 5000
Sigma-Aldrich
Acetonitrile, suitable for chromatography
Sigma-Aldrich
Dichloromethane, JIS special grade, ≥99.0%
Sigma-Aldrich
Acetonitrile, ≥99.8%, suitable for residue analysis, JIS 1000
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%, poly-coated bottles