Millipore Sigma Vibrant Logo

Prefiltros RW

Mixed cellulose ester with polyester support

Recursos relacionados

Descripción

Especificaciones

Información para pedidos

Ir
Tipo RW03Borrar Clasificación y Filtrado Show Filter
Número de referenciaDiámetro del filtro (⌀)Tamaño de envase
RW030470047 mm 100 Precios y disponibilidad

Volver al principio

Tipo RW06Borrar Clasificación y Filtrado Show Filter
Número de referenciaDiámetro del filtro (⌀)Tamaño de envase
RW0614250142 mm 50 Precios y disponibilidad

Volver al principio

Tipo RW19Borrar Clasificación y Filtrado Show Filter
Número de referenciaDiámetro del filtro (⌀)Tamaño de envase
RW190470047 mm 100 Precios y disponibilidad
RW1914250142 mm 50 Precios y disponibilidad

Volver al principio

AccesorioBorrar Clasificación y Filtrado Show Filter
Número de referenciaDescripciónTamaño de envase
XX6200006PPinzas de bordes planos, acero inoxidable 3 Precios y disponibilidad

Volver al principio

Documentation

Preguntas frecuentes

PreguntaRespuesta
Which side of the membrane should I use, the shiny or dull side?Most researchers may not even notice that there is a "sidedness" to filters, and, for most applications, orientation will not affect filter performance. However, membranes do have a slightly asymmetric pore structure: the shiny side of the membrane is the "tighter" side. In some applications, you can take advantage of this difference by selecting a specific filter orientation. ultrafiltration membranes should always be used shiny side up, regardless of application for drop dialysis ( a buffer exchange technique in which a few drops of DNA or protein are placed in a 0.05 or 0.025 um filter and floated on a buffer solution), apply the sample to the shiny side of the filter and float the filter dull side to the buffer. This measure will enhance buffer exchange and discourage sample loss. The Millipore Express and Express Plus membranees are also sided - these membranes should be used shiny side facing down.
What is the difference between pore size and pore size distribution?Whereas pore size is a measure of the diameter of the largest pore, pore size distribution is a measure of the range of pore sizes. The range of pore sizes can be normally distributed, and the spread can be quite narrow (e.g. the ratio of largest to smallest may be less than 2). On the other hand, pore size distribution can be very heterogeneous. In the case of large spreads and heterogeneity, the pore size will be far less predictive of flow rate (either filtration or capillary) than it will be for a membrane with a narrow pore size distribution. It is important to note that the pore size corresponding to the bubble point is not at the middle of the distribution, but is the largest pore.