MicropreSure On-Line Filtration System
 
MicropreSure On-Line Filtration Samplers simplify in-process microbiological testing.
 More
MicropreSure On-Line Filtration Samplers simplify in-process microbiological testing. Less
 
More>>
Less<<
Related Resources

Recommended Products
- 
  PCC030C30E Millipore Pellicon® Capsule with Ultracel® Membrane, C Screen, 3 m2 manifold extender with AseptiQuik® L connectors
- 
  3000-OP Millipore OmniPur® Calcium Chloride, Dihydrate - CAS 10035-04-8 - Calbiochem
- 
  1048735000 Supelco Potasium dihidrogen fosfat
- 
  FCMAB203P Sigma-Aldrich Milli-Mark™ Anti-CD64-PE Antibody, clone 10.1
- 
  1702270100 Supelco Molybdenum standard solution
- 
  C10703 Hydrophobic Edge Membranes
- 
  102529 Supelco Kobalt(II) asetat tetrahidrat
- 
  1083251000 Supelco Toluena
- 
  410957-250MG Sigma-Aldrich 3-Isobutyl-1-methylxanthine - CAS 28822-58-4 - Calbiochem
- 
  14-657 Sigma-Aldrich DAPK2 Protein, active, 10 µg
Overview
Specifications
Ordering Information
Documentation
Related Products & Applications
Related Products By: Application Facete
| Sterility Testing | 
| Dialysis and Filtration | 
Related Products By: Brand Facete
| Micropresure® | 
Categories
| Industrial Microbiology > Bioburden Testing > Bioburden Testing for Pharmaceutical & Cosmetics Industry | 
Description
Validation engineers and Quality Control specialists regularly sample the drops and tanks of process water loops to ensure low bacterial levels and to identify bio-contamination problems early. Traditional multi-step sampling methods are often inconvenient and a potential problem for time-pressed personnel. The routine of setting up lab equipment and processing samples can be rushed, sometimes at the expense of proper aseptic procedures.
By reducing the sampling process to a few simple steps performed within a closed system, the MicropreSure on-line filtration sampler improves microbiological testing of purified water at the point-of-use. This on-line filtration sampler complies with USP/EP guidelines.
Closed Design for Accurate Sampling
The simple, protective design of the MicropreSure sampler provides dependable microbiological sampling and reduces contamination risk in any environment. Organisms are captured on the membrane right at the collection site, providing a representative sample for accurate enumeration. The filtration chamber remains closed during all stages of sampling, so operator skill and environmental control are less critical.
Fast and Reliable In-Process Collection
The MicropreSure sampler and monitor saves steps and speeds collection - providing an easy method to secure the samples you need for tracking and trending process water purity. It uses the pressure in tanks or pressurized lines to process and collect samples through a microporous membrane within an enclosed chamber.
And because the MicropreSure devices are securely locked together, sampling pressurized water lines will not create water leaks.
Sampling and Filtration in One Step
MicropreSure samplers and monitors are sterile and ready to use. With MicropreSure on-line filtration samplers, you sample and process in one step, eliminating the need to sterilize sample containers or transport them back to the laboratory. After processing, microbes are contained and protected within the lightweight MicropreSure devices that are easily carried.
Tests Larger Volumes or During an Extended Period of Time
During validation, a 100 mL sample may not reveal low level microbial contaminants in a water sample. The MicropreSure sampler and monitor allows for processing liters of water through its enclosed housing. In addition, the strong fit between the Luer fitting and the sanitary sampling valve means you can continuously sample over an extended period of time. Results can then reflect build-up contamination over a batch, a shift, or a day.
Convenient In-Process Microbiological Analysis
The MicropreSure sampler and monitor are innovative and convenient tools that allow water samples to be aseptically processed, right at the collection site. The membrane, enclosed in its own housing, is protected until it is ready to be processed in the laboratory.
MicropreSure On-Line Filtration Samplers and Monitors Improve Traditional Multiple-step Sampling Methods:
- No assembly 
- No sterilization 
- No sample containers to transport 
- No risk of external contamination
Identifying the Sampling Port Outlet and Choosing the Valve Adapter
If the sampling port outlet is a male Luer port, use the MicropreSure on-line filtration sampler without a valve outlet adapter.
Otherwise, install a MicropreSure sanitary sampling valve, or install a valve outlet adapter.
| Materials of Construction | |
| Filtration Chamber/Base | Polycarbonate (PC) | 
| Membrane | Mixed Cellulose Esters (MCE) | 
| Filter Support | High density polyethylene | 
| Dimensions | |
| Device Height, mm | 45 | 
| Filter Diameter | 47 mm | 
| Pore Size | 0.45 µm | 
| Filtration Area | 9.1 cm² | 
| Pressure Limit | |
| at 25 °C | 3 bar | 
| at 90 °C | 1 bar | 
| Temperatute Range, °C | 5 – 90 | 

 


 
  

 