CS20MS01H1
Clarisolve® Pod Depth Filter
20MS, 20µm, filtration area 0.014 m², High-density cell cultures, Lab Scale
Synonym(s):
Clarisolve 20 μm Lab Scale Depth Filters, 0.014 m2 (0.15 ft2)
About This Item
Skip To
Product Name
Clarisolve® Pod Depth Filter,
Quality Level
1 of 4
This Item | CS60HX01H1 | CS40MS01H1 | CS20MS02H1 |
---|---|---|---|
filtration area 0.014 m2 | filtration area 0.014 m2 | filtration area 0.014 m2 | filtration area 0.027 m2 |
material Millistak+® media, polypropylene , TPE seal | material TPE seal, polypropylene | material Millistak+® media, TPE seal, polypropylene | material Millistak+® media, TPE seal, polypropylene |
impurities <0.25 EU/mL (LAL test, Aqueous extraction; on filter media only) | impurities <0.25 EU/mL (LAL test, Aqueous extraction; on filter media only) | impurities <0.25 EU/mL (LAL test, Aqueous extraction; on filter media only) | impurities <0.25 EU/mL (LAL test, Aqueous extraction; on filter media only) |
conductivity 0.80 – 1.59 μS/cm | conductivity ≤0.15 μS/cm | conductivity 0.91 – 1.29 μS/cm | conductivity 0.80 – 1.59 μS/cm |
parameter 2.1 bar max. differential pressure (30 psid) at 37 °C (Forward), 2.1 bar max. differential pressure (30 psid) at 37 °C (Reverse) | parameter 2.1 bar max. differential pressure (30 psid) at 37 °C (Forward), 2.1 bar max. differential pressure (30 psid) at 37 °C (Maximum), 2.1 bar max. differential pressure (30 psid) at 37 °C (Reverse), 2.1 bar max. differential pressure (30 psid) at 4 °C (Forward) | parameter 2.1 bar max. differential pressure (30 psid) at 37 °C (Forward), 2.1 bar max. differential pressure (30 psid) at 37 °C (Maximum), 2.1 bar max. differential pressure (30 psid) at 37 °C (Reverse), 2.1 bar max. differential pressure (30 psid) at 4 °C (Forward) | parameter 2.1 bar max. differential pressure (30 psid) at 37 °C (Forward), 2.1 bar max. differential pressure (30 psid) at 37 °C (Maximum), 2.1 bar max. differential pressure (30 psid) at 37 °C (Reverse), 2.1 bar max. differential pressure (30 psid) at 4 °C (Forward) |
manufacturer/tradename Clarisolve® | manufacturer/tradename Clarisolve® | manufacturer/tradename Clarisolve® | manufacturer/tradename Clarisolve® |
General description
Application
Features and Benefits
Preparation Note
Integrity is maintained after 2 autoclave cycles of 60 minutes at 123 °C.
Analysis Note
Legal Information
Storage Class Code
13 - Non Combustible Solids
WGK
nwg
Flash Point(F)
Not applicable
Flash Point(C)
Not applicable
What is the Emprove® Program?
The Emprove® Program is a system providing comprehensive and thorough documentation of our filters and single-use components, pharma raw materials, and starting materials. Four document types are included with an Emprove® Program subscription:
Free of charge - Sign in to download
Free of charge - Sign in to download
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Active Filters
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service