조직 및 계약 가격을 보려면 로그인를 클릭합니다.
크기 선택
보기 변경
제품정보 (DICE 배송 시 비용 별도)
NACRES:
NB.21
UNSPSC Code:
41115711
Feature:
binder Organic Polymer, fluorescent indicator
Particle size:
5-6 μm
Pore size:
60 Å medium pore diameter
Layer thickness:
150-200 μm
Plate l × w:
20 cm × 10 cm
Material:
glass support, silica gel 60 matrix
Quality Segment
material
glass support, silica gel 60 matrix
feature
binder Organic Polymer, fluorescent indicator
packaging
pkg of 25 plates
technique(s)
HPTLC: suitable
layer thickness
150-200 μm
plate L × W
20 cm × 10 cm
particle size
5-6 μm
pore size
60 Å medium pore diameter
storage temp.
2-30°C
General description
25 Glass plates 20 x 10 cm
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. Our concentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the second is a selective layer for separation. Regardless of the spots’ shape, size, or position, the sample always concentrates as a narrow band where the two adsorbents overlap and where the separation starts. These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples.
Analysis Note
Specific surface area (according to BET; 5-Pt. measurement): 480 - 540 m²/g
Pore volume (N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution): 5 - 7 µm
Layer thickness: 150 - 200 µm
Deviation of layer thickness per plate: ≤ 35 µm
layer thickness concentrating zone: 70 - 110 µm
Fluctuation in the thickness of the concentration zone: ≤ 35 µm
Chromatographic testings:
A) cholesterin test
hRf-values
- cholesterin, cholesterin test:
11 - 23
B) Steroide test
- methyltestosterone, steroid test: 20 - 40
- Reichstein S, steroid test: 50 - 70
- hydrocortisone, steroid test: 65 - 85
Typical value determined on a activated plate (120°C, 15 min)
Eluent a) acetone/ water (95/5 v/v)
Eluent b) acetonitrile/ water (70/30 v/v)
Pore volume (N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution): 5 - 7 µm
Layer thickness: 150 - 200 µm
Deviation of layer thickness per plate: ≤ 35 µm
layer thickness concentrating zone: 70 - 110 µm
Fluctuation in the thickness of the concentration zone: ≤ 35 µm
Chromatographic testings:
A) cholesterin test
hRf-values
- cholesterin, cholesterin test:
11 - 23
B) Steroide test
- methyltestosterone, steroid test: 20 - 40
- Reichstein S, steroid test: 50 - 70
- hydrocortisone, steroid test: 65 - 85
Typical value determined on a activated plate (120°C, 15 min)
Eluent a) acetone/ water (95/5 v/v)
Eluent b) acetonitrile/ water (70/30 v/v)
Other Notes
Replaces: 15498-6; 15498
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.