콘텐츠로 건너뛰기
Merck

KR75A10HH1

Opticap® XL10 Polygard®-CR 75 µm 9/16 in. HB/HB

동의어(들):

Opticap® XL10 Polygard®-CR 75 µm 9/16 in. HB/HB

조직 및 계약 가격을 보려면 로그인를 클릭합니다.

크기 선택

보기 변경

제품정보 (DICE 배송 시 비용 별도)

eCl@ss:
32031690
UNSPSC Code:
23151806
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의


제품 이름

Opticap® XL 10 CapsuleMedia: Polygard®-CR 75.0 µm Nominal, Chemistry: Polypropylene (PP)Inlet: 9/16 in. Hose BarbOutlet: 9/16 in. Hose BarbMax Operating Pressure: 80 psi @ 25 °C

material

polypropylene , polypropylene housing (PP), polypropylene support, polypropylene vent cap, silicone seal

sterility

(3 autoclave cycles of 30 min @ 126 °C; not in-line steam sterilizable)

sterilization compatibility

autoclavable compatible

parameter

1.0 bar max. inlet pressure (15 psi) at 80 °C, 2.75 bar max. inlet pressure (40 psi) at 60 °C, 25 °C max. inlet temp., 4.8 bar max. differential pressure (70 psid) at 20 °C, 5.5 bar max. inlet pressure (80 psi) at 25 °C, 80 psig max. inlet pressure

L

33.5 cm (13.2 in.)

cartridge nominal length

10 in. (25 cm)

device size

10 in.

diam.

10.7 cm (4.2 in.) , 4.2 in. (10.7 cm)

inlet connection diam.

9/16 in.

outlet W

33.5 cm (13.2 in.)

outlet connection diam.

9/16 in.

impurities

≤0.5 EU/mL Aqueous extraction (LAL test)

matrix

Polygard®-CR

pore size

75.0 μm nominal pore size, 75.0 μm

fitting

14 mm (9/16 in.) hose barb, inlet hose barb, outlet hose barb

suitability

suitable for endotoxin

General description

A sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.

Packaging

Double Easy-Open bag

Analysis Note

The extractables level was equal to or less than 55 mg per capsule after 24 hours in water at controlled room temperature.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L

Other Notes

EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.

Legal Information

OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany
POLYGARD is a registered trademark of Merck KGaA, Darmstadt, Germany

Disclaimer

All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.


저장 등급

10-13 - German Storage Class 10 to 13



가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문