Can I use Centrifree with a swinging-bucket rotor?Yes, but the filtration rate will be only 30-50% of that produced with a fixed-angle rotor at the same g-force. What are the pore and retention characteristics of the YMT 30,000 molecular weight cut-off membrane for Centrifree micropartition device?The actual pore size is not measured. The membrane is characterized by measuring its retention of known protein markers of specific molecular weights. The given cut-off is a nominal measurement. Does Centrifree have a shelf life?Yes, one year. What is the maximum spinning speed of the Centrifree unit?Device limits are measured in g-force, not rpm. The maximum recommended g-force is 2000 × g. How much ultrafiltrate can I expect when using the Centrifree?For volumes less than 0.5 ml: For a sample volume of 1.0 ml: In 10 minutes: I 1/2 the initial volume approximately 200 µl In 30 minutes: 2/3 to 3/4 the initial volume approximately 450 µl What is the maximum process volume for the Centrifree device?Maximum volume is 1.0 ml. What molecular weight cut-off does the Centrifree come in?The Centrifree unit is available in a 30,000 MW cut-off. Can I reuse Centrifree?No, Centrifree is intended for one-time use only. Multiple use risks membrane failure. What is the minimum process volume for the Centrifree device?Minimum volume is 0.15 ml. What temperatures can Centrifree be spun at?Spin devices at 4-50°C. Store at room temperature. What membranes should I use with MPS-1?The MPS-1 unit accepts a variety of 14mm membranes. The following is a list of molecular weight cut-offs available and the corresponding catalog numbers: What centrifuge can I use with the Centrifree?Any centrifuge with a fixed angle rotor or carrier that can accommodate 17 × 100 mm tubes and is capable of 1000-2000 g. Can I sterilize Centrifree?Yes. Centrifree can be sterilized using ethylene oxide gas. How long do I spin the Centrifree?1ml of normal human serum spun in a fixed angle rotor will produce 125-130ul of ultrafiltrate in 10 minutes. 1ml of normal human serum spun in a swinging bucket will produce 115-120ul of ultrafiltrate in 10 minutes. Is Centrifree autoclavable?No, the Centrifree unit is not autoclavable. When using the Centrifree unit, why do identical serum samples occasionally have different flow rates in my swinging-bucket rotor?When using a swinging-bucket rotor, the pattern of buildup of retained protein at the membrane surface is random, therefore it is not unusual to detect different flow rates. Because that protein layer is able to cover the entire membrane surface, the flow rate is slower compared to the rate in a fixed-angle rotor. Use of a fixed-angle rotor counteracts buildup of retained protein at the membrane surface because the angle causes this dense protein layer to slide outward and accumulate at the edge of the membrane. When was the color/material of the Centrifree O-ring changed?The color was changed from gray bromobutyl to black ethylene-propylene-diene-monomer(EPDM) in 1999. The product’s specifications and functional performance will not be altered as a result of this change in material.