Standard Area Cartridges with Silicone O-rings · Code 0, 2-222 O-ringClear Sorting & Filtering Show Filter
Catalogue NumberPore SizeCartridge Nominal Length
CHVE01TS30.5 / 0.1 µm 10 in. (25 cm)

Packaged 3 cartridges per box.

Back To Top

Standard Area Cartridges with Silicone O-rings · Code 7, 2-226 O-ring w/locking-tabs and spearClear Sorting & Filtering Show Filter
Catalogue NumberPore SizeCartridge Nominal Length
CHVE75TS30.5 / 0.1 µm 5 in. (12.5 cm)
CHVE71TS30.5 / 0.1 µm 10 in. (25 cm)
CHVE71TS10.5 / 0.1 µm 10 in. (25 cm)
CHVE72TS30.5 / 0.1 µm 20 in. (50 cm)
CHVE73TS30.5 / 0.1 µm 30 in. (75 cm)
CVEP75TS30.1 µm 5 in. (12.5 cm)
CVEP71TS30.1 µm 10 in. (25 cm)
CVEP71TS10.1 µm 10 in. (25 cm)
CVEP72TS30.1 µm 20 in. (50 cm)
CVEP73TS30.1 µm 30 in. (75 cm)

Packaged 3 cartridges per box.
The 10" Code 7 cartridges exist as 1 per box for validation studies (replace last digit by 1)

Back To Top

High Area Cartridges with Silicone O-rings · Code 7, 2-226 O-ring w/locking-tabs and spearClear Sorting & Filtering Show Filter
Catalogue NumberPore SizeCartridge Nominal Length
CHVE72HS30.5 / 0.1 µm 20 in. (50 cm)
CHVE73HS30.5 / 0.1 µm 30 in. (75 cm)

Packaged 3 cartridges per box.

Back To Top

Standard Area Cartridges with EPDM O-rings · Code 7, 2-226 O-ring w/locking-tabs and spearClear Sorting & Filtering Show Filter
Catalogue NumberPore SizeCartridge Nominal Length
CHVE71TE30.5 / 0.1 µm 10 in. (25 cm)
CHVE72TE30.5 / 0.1 µm 20 in. (50 cm)
CVEP71TE30.1 µm 10 in. (25 cm)
CVEP72TE30.1 µm 20 in. (50 cm)
CVEP73TE30.1 µm 30 in. (75 cm)

Packaged 3 cartridges per box.
The 10" Code 7 cartridges exist as 1 per box for validation studies (replace last digit by 1)

Back To Top

High Area Cartridges with EPDM O-rings · Code 7, 2-226 O-ring w/locking-tabs and spearClear Sorting & Filtering Show Filter
Catalogue NumberPore SizeCartridge Nominal Length
CHVE71HE10.5 / 0.1 µm 10 in. (25 cm)
CHVE71HE30.5 / 0.1 µm 10 in. (25 cm)
CHVE72HE30.5 / 0.1 µm 20 in. (50 cm)
CHVE73HE30.5 / 0.1 µm 30 in. (75 cm)

Packaged 3 cartridges per box.

Back To Top

Cartridges with Fluorocarbon Rubber O-rings · Code 7, 2-226 O-ring w/locking-tabs and spearClear Sorting & Filtering Show Filter
Catalogue NumberPore SizeCartridge Nominal Length
CHVE71TF30.5 / 0.1 µm 10 in. (25 cm)
CHVE72TF30.5 / 0.1 µm 20 in. (50 cm)
CHVE73TF30.5 / 0.1 µm 30 in. (75 cm)
CVEP71TF30.1 µm 10 in. (25 cm)
CVEP72TF30.1 µm 20 in. (50 cm)
CVEP73TF30.1 µm 30 in. (75 cm)

Packaged 3 cartridges per box.
The 10" Code 7 cartridges exist as 1 per box for validation studies (replace last digit by 1)

Back To Top

High Area Cartridges with Fluoroelastomer O-rings · Code 7, 2-226 O-ring w/locking-tabs and spearClear Sorting & Filtering Show Filter
Catalogue NumberPore SizeCartridge Nominal Length
CHVE71HF10.5 / 0.1 µm 10 in. (25 cm)
CHVE71HF30.5 / 0.1 µm 10 in. (25 cm)
CHVE72HF30.5 / 0.1 µm 20 in. (50 cm)
CHVE73HF30.5 / 0.1 µm 30 in. (75 cm)

Packaged 3 cartridges per box.

Back To Top

Documentation

Material Qualification Dossier

TitleVersion
3.0

Operational Excellence Dossier

Title

References

Reference overview
Mobile Phase Preparation for UHPLC: Membrane Filtration Method Affects System Performance and Leaching of Extractable Impurities
Subodh Kulkarn(1), Jesmi George(2) and Vivek Joshi(2) (1) Millipore India Pvt. Ltd., Bioscience Division, 50A, 2nd Phase, Ring Road, Peenya, Bangalore, India 560058 (2) Millipore Corp., Bioscience Division, 17 Cherry Hill Drive, Danvers, MA 01923
LCGC  2010

Show Abstract Full Text Article
"Schneller und effizienter" (Faster and more efficient)
Ulrich Hoebel, Key Account Manager for Boehringer Ingelheim & Regional Sales Manager in Central Area
Biotechnica Today, official journal of the Hannover tradeshow Biotechnica, published by the German magazine Laborpraxis, issue October 18 2005, page 9  2005

Filtración esterilizante rápida y económica: tecnologia de membrana Express® (Faster Sterile Filtration with New Membrane Technology)
Josep Vilella, Bioprocess Marketing, Tech Service and internal Support Specialist in Spain
Tecnicas de Laboratorio (Spanish magazine), issue 306, November 2005 , page 975  2005

Related Products & Applications

Product Families

Related Products By: Application Facete

Related Products By: Brand Facete

Categories

Biopharmaceutical Manufacturing > Downstream Processing > Sterile Filtration > Sterile Liquid > Millipore Express® > Millipore Express® SHR