Permítanos ayudarleAC/DC input
100 V / 230 V, 50-60 Hz
agency
EP 2.6.1, USP 71
71
product line
Milliflex®
packaging
pkg of 1 kit
parameter
10 kg operating weight (22 lb) (Autospray Station), 5 kg operating weight (11 lb) (Detection Tower)
technique(s)
Rapid Sterility Testing: suitable
H × W × D
31 cm (12 in.) × 21 cm (8 in.) × 40 cm (16 in.), Auto Spray Station, 35 cm (14 in.) × 30 cm (12 in.) × 13 cm (5 in.), Detection Tower
application(s)
bioburden testing
sterility testing, pharmaceutical
water monitoring
compatibility
for use with Milliflex Oasis®
General description
Milliflex® Rapid 2.0 Kit is an automated solution for rapid detection, imaging, and quantification of viable microbes in filterable solutions.
The detection method is based on highly sensitive ATP bioluminescence technology. The ATP method is regulatory compliant, highly reliable, and consistent with the detection rates matching the standards of current compendial testing methods.
The conventional way of visual evaluation is replaced by Complementary Metal Oxide Semiconductor (CMOS) in Milliflex® Rapid system. The state-of-the-art image analysis and optimized reagents require reduced incubation time for viable microbial detection.
The image analysis software intensifies (~1000 times) the bioluminescence from each microbial micro-colony and captures the light signals emitted by the microbes. The software enumerates the colonies and displays results as CFU (colony forming unit).
The detection method is based on highly sensitive ATP bioluminescence technology. The ATP method is regulatory compliant, highly reliable, and consistent with the detection rates matching the standards of current compendial testing methods.
The conventional way of visual evaluation is replaced by Complementary Metal Oxide Semiconductor (CMOS) in Milliflex® Rapid system. The state-of-the-art image analysis and optimized reagents require reduced incubation time for viable microbial detection.
The image analysis software intensifies (~1000 times) the bioluminescence from each microbial micro-colony and captures the light signals emitted by the microbes. The software enumerates the colonies and displays results as CFU (colony forming unit).
Application
Milliflex® Rapid 2.0 system is a perfect rapid solution used for bioburden and sterility testing. The system is compatible with a wide range of filterable samples from pharmaceutical, beverage, and personal care industries.
Features and Benefits
Milliflex® Rapid 2.0 system has the following features and benefits:
- Consistent, fast, and reproducible results.
- Correlation of CFU counts with that of traditional methods.
- Data Integrity Software compliant with 21 CFR Part 11.
- Easy Handling and Validation.
Other Notes
Download the Milliflex® Rapid System 2.0 software from here
Milliflex® Rapid 2.0 Kit includes the following components:
- Detection Tower -MXRDP2DT00)
- Auto Spray station - MXRP2SPRKT
- 2 x Power Supplies required (not included, sold separately, region specific under MXRPWRSP--)
Legal Information
MILLIFLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLIFLEX OASIS is a registered trademark of Merck KGaA, Darmstadt, Germany
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Número de artículo de comercio global
| SKU | GTIN |
|---|---|
| MXRDP2KT01 | 04065269118114 |