Skip to Content
Merck

MABF3128

Anti-CD244/2B4 Antibody, clone C1.7

Synonym(s):

NK cell activation-inducing ligand (NAIL), NK cell type I receptor protein 2B4 (NKR2B4, h2B4), Natural killer cell receptor 2B4, SLAM family member 4 (SLAMF4), Signaling lymphocytic activation molecule 4

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View

About This Item

UNSPSC Code:
12352203
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Quality Level

biological source

mouse

antibody form

purified antibody

antibody product type

primary antibodies

clone

C1.7, monoclonal

mol wt

calculated mol wt 41.62 kDa, observed mol wt ~N/A kDa

purified by

using protein G

species reactivity

human

packaging

antibody small pack of 100

technique(s)

flow cytometry: suitable, inhibition assay: suitable, western blot: suitable

isotype

IgG1κ

epitope sequence

Extracellular domain

Protein ID accession no.

UniProt accession no.

storage temp.

-10 to -25°C

Gene Information

human ... CD244(51744)

General description

Natural killer cell receptor 2B4 (UniProt: Q9BZW8; also known as CD244, NK cell activation-inducing ligand (NAIL), NK cell type I receptor protein 2B4 (NKR2B4; h2B4), SLAM family member 4 (SLAMF4), Signaling lymphocytic activation molecule 4) is encoded by the CD244 (also known as 2B4) gene (Gene ID: 51744) in human. CD244 (2B4) is a SLAM family receptor broadly expressed on NK cells, subsets of CD8+ αβ and γδ T cells, dendritic cells, and myeloid-derived suppressor cells (MDSCs), where it binds CD48 and signals via four ITSM motifs that recruit SH2 adaptors to drive activating (SAP) or inhibitory (SHP1/SHP2/SHIP-1; context-dependent EAT-2) outcomes; the net signal is governed by receptor density and adaptor availability, with high CD244 and/or limited SAP favoring inhibition. In the tumor microenvironment, CD244 signaling is predominantly inhibitory—promoting NK and CD8+ T-cell exhaustion and dampening cytokine production, while in DCs and Gr-MDSCs it aligns with increased immunosuppressive function—mechanisms often dependent on CD244–CD48 interactions with tumor-associated immune cells. These insights support therapeutic CD244 blockade to reinvigorate exhausted effectors, enhance proinflammatory DC activity, and diminish MDSC-mediated suppression; supportive preclinical data, the grossly normal phenotype of CD244−/− mice, and evidence that leukemia cells can depend on CD244 signaling, collectively underscore CD244 as a promising immuno-oncology target.

Immunogen

Cultured human NK cells.

Application

Quality Control Testing

Evaluated by Flow Cytometry in human Peripheral Blood Mononuclear Cells (PBMC).
Flow Cytometry Analysis: 1.0 µg from a representative lot detected CD244/2B4 in one million human Peripheral Blood Mononuclear Cells (PBMC).
Inhibition:  A representative lor of this antibody inhibited non-MHC-restricted cytotoxicity mediated by resting NK cells and rlL-2- cultured T cells. (Valiante, N.M., et al. (1993). J Exp Med. 178(4):1397-406).
Western Blotting Analysis: A representative lot detected CD244/2B4 in Western Blotting application (Valiante, N.M., et al. (1993). J Exp Med. 178(4):1397-406).
Flow Cytometry Analysis: A representative lot detected CD244/2B4 in Flow Cytometry application (Valiante, N.M., et al. (1993). J Exp Med. 178(4):1397-406).
Note: Actual optimal working dilutions must be determined by end user as specimens, and experimental conditions may vary with the end user.

Biochem/physiol Actions

Clone C1.7 is a mouse monoclonal antibody that detects CD244/2B4. It targets an epitope from the extracellular domain.

Physical form

Purified mouse monoclonal antibody IgG1κ in PBS without azide.

Preparation Note

1.0 mg/mL. Please refer to guidance on suggested starting dilutions and/or titers per application and sample type.
Store at -10°C to -25°C. Handling Recommendations: Upon receipt and prior to removing the cap, centrifuge the vial and gently mix the solution. Aliquot into microcentrifuge tubes and store at -20°C. Avoid repeated freeze/thaw cycles, which may damage IgG and affect product performance.

Analysis Note

Concentration: Please refer to the Certificate of Analysis for the lot-specific concentration.

Other Notes

1. Valiante, N.M., et al. (1993). J Exp Med. 178(4):1397-406.

Disclaimer

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.


Still not finding the right product?

Try our Product Selector Tool to narrow your options


Storage Class

12 - Non Combustible Liquids

flash_point_f

Not applicable

flash_point_c

Not applicable



Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library