description
0.24-1.95pg/mL, refer to CoA for lot-specific LLOQ
Quality Level
product line
SMC®
usage
kit sufficient for 96 wells
species reactivity
human
manufacturer/tradename
SMC®
technique(s)
single molecule counting: suitable
input
serum
plasma
cerebrospinal fluid (CSF)
assay range
inter-assay cv: <15%
intra-assay cv: <20%
(Sensitivity: LLOQ 980 fg/mL* (SMCxPRO® Instrument); Standard Curve Range: 244-250,000 fg/mL; Linearity: CSF: 100%; Recovery: Plasma: 94% CSF: 92%; *Indicative LLOQ created from average of 14 independent in house runs, where >80% met same value defined with CV & Recovery +/- 20%. Refer to CoA for lot specific performance.)
compatibility
for use with for use with FemtoQuest™ and SMCxPRO® instruments (validated)
shipped in
wet ice
storage temp.
2-8°C
General description
Aβ1-42 plays a critical role in the pathogenesis of Alzheimer′s disease. Elevated levels of Aβ1-42 are associated with the development of amyloid plaques, which can disrupt neuronal function, trigger neuroinflammation, and lead to neuronal cell death. The presence of Aβ1-42 in the cerebrospinal fluid (CSF) is often inversely correlated with cognitive decline, making it a valuable biomarker for early diagnosis and monitoring of Alzheimer′s disease. Understanding the function and implications of Aβ1-42 is essential for developing targeted therapies aimed at reducing amyloid burden and mitigating its detrimental effects on brain health in neurodegenerative conditions.
Application
Biochem/physiol Actions
Features and Benefits
- High Sensitivity Detection: Precisely quantifies Amyloid Beta 1-42 at femtogram/mL levels in plasma or CSF.
- Improved Dynamic Range: Enhanced signal-to-noise ratio with reduced background interference for reliable assay performance.
- User-Friendly Workflow: Utilizes a familiar sandwich immunoassay format while ensuring high sensitivity for Aβ1-42 detection.
- Automation-Ready: Compatible with automated liquid handling systems, reducing manual steps and increasing lab efficiency.
Packaging
Analysis Note
Neurological Disorders
Neurodegenerative Diseases
Alzheimer′s Disease
Legal Information
Disclaimer
Signal Word
Danger
Hazard Statements
Precautionary Statements
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Irrit. 2 - Repr. 1B - STOT RE 2 Inhalation
Target Organs
Respiratory Tract
Storage Class Code
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Related Content
Explore high-sensitivity SMC® neurology immunoassays that precisely measure low levels of neurology protein analytes, such as NF-L or Tau proteins.
Explore ultrasensitive immunoassay technology with SMC® technology, including its biomarker detection platform, advantages of high sensitivity assays, and more.
Discover how to expand neuroscience biomarker research with high sensitivity immunoassays, such as Single Molecule Counting (SMC®) assays. These assays give researchers the tools they need to detect low-abundant blood-based biomarkers and expand biomarker options in neuroscience research.
Find immunoassays to explore neuroimmunology and neuroinflammation cytokines and neurodegenerative disease biomarkers.
Global Trade Item Number
| SKU | GTIN |
|---|---|
| 03-0146-00 | 04054839166433 |
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service