Select a Size
About This Item
InChI key
VZTDIZULWFCMLS-UHFFFAOYSA-N
InChI
1S/CH2O2.H3N/c2-1-3;/h1H,(H,2,3);1H3
SMILES string
N.OC=O
description
anionic
Quality Level
product line
LiChropur™
assay
≥99.0% (calc. on dry substance, NT), ≥99.0%
form
crystals
quality
LiChropur™
technique(s)
LC/MS: suitable
impurities
insoluble matter, passes filter test, <2% water
ign. residue (900°C)
<0.1% (as SO4)
pH
5.5-7.5 (25 °C, 1 M in H2O)
mp
119-121 °C (lit.)
solubility
H2O: 1 M at 20 °C, clear, colorless
density
1.26 g/mL at 25 °C (lit.)
anion traces
chloride (Cl-): ≤50 mg/kg, sulfate (SO42-): ≤50 mg/kg
cation traces
Al: ≤1 mg/kg, As: ≤0.1 mg/kg, Ba: ≤1 mg/kg, Bi: ≤1 mg/kg, Ca: ≤5 mg/kg, Cd: ≤1 mg/kg, Co: ≤1 mg/kg, Cr: ≤1 mg/kg, Cu: ≤1 mg/kg, Fe: ≤1 mg/kg, K: ≤5 mg/kg, Li: ≤1 mg/kg, Mg: ≤1 mg/kg, Mn: ≤1 mg/kg, Mo: ≤1 mg/kg, Na: ≤5 mg/kg, Ni: ≤1 mg/kg, Pb: ≤1 mg/kg, Sr: ≤1 mg/kg, Zn: ≤1 mg/kg
λ
1 M in H2O
UV absorption
λ: 260 nm Amax: ≤0.01, λ: 280 nm Amax: ≤0.01
Looking for similar products? Visit Product Comparison Guide
General description
Application
Ammonium formate has been used in the separation of non-steroidal anti-inflammatory drugs and of oligosaccharide mixtures using capillary electrochromatography. It is also used in the analysis of phosphatidylserines, triacylglycerols and triacylglycerol oxidation products, and oligogalacturonic acids using HPLC and HPLC-MS methods.
Legal Information
signalword
Warning
hcodes
Hazard Classifications
Eye Irrit. 2
Storage Class
11 - Combustible Solids
wgk
WGK 1
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
dust mask type N95 (US), Eyeshields, Gloves
Regulatory Listings
Regulatory Listings are mainly provided for chemical products. Only limited information can be provided here for non-chemical products. No entry means none of the components are listed. It is the user’s obligation to ensure the safe and legal use of the product.
70221-100G-F: + 70221-BULK-F: + 70221-VAR-F: + 70221-25G-F:
jan
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Articles
This application note describes the released N-Glycan analysis of a monoclonal antibody, cetuximab, labeled with procainamide, using a BIOshell™ Glycan HPLC column.
Protocols
AMP(アデノシン一りん酸)とATP(アデノシン三りん酸)の分離
HPLC Analysis of Polyphenols in Nero d'Avola Red Wine on Discovery® HS C18 (UV 280 nm)
Protocol for HPLC Analysis of Bromelain on TSKgel® BioAssist® S vs. Competitive S Column
HPLC Analysis of Immunoglobulin G (IgG) on Zenix® SEC-150 versus Zenix® SEC-300, Effect of Pore Size on Resolution
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service