제품 이름
Opticap® XLT 20 CapsuleMedia: Millipore Express® SHC High Area 0.5 / 0.2 µm, Chemistry: Hydrophilic Polyethersulfone (PES)Inlet: 1-1/2 in. Sanitary FlangeOutlet: 1 in. Hose BarbT-lineMax Operating Pressure: 80 psi @ 25 °C
Quality Segment
material
polyester support, polyethersulfone , polypropylene , polypropylene housing, polypropylene vent cap, polysulfone , silicone seal
reg. compliance
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
sterility
non-sterile
sterilization compatibility
gamma compatible
product line
Opticap® XLT 20
feature
hydrophilic
manufacturer/tradename
Millipore Express®
parameter
≤112.8 mL/min air diffusion at 2.75 bar (40 psig) and 23 °C (in water), 1.0 bar max. differential pressure (15 psi) at 80 °C (Forward), 2.1 bar max. differential pressure (30 psi) at 25 °C (Reverse; intermittent), 25 °C max. inlet temp., 5.5 bar max. differential pressure (80 psi) at 25 °C (Forward), 6.9 bar max. differential pressure (100 psi) at 25 °C (Forward; intermittent), 80 psig max. inlet pressure
technique(s)
sterile filtration: suitable
L
62.5 cm (24.6 in.)
W
7.8 in.
cartridge nominal length
20 in. (50 cm)
diam.
10.7 in. (4.2 cm)
filtration area
2.0 m2
inlet to outlet W
17.5 cm (6.9 in.)
outlet connection diam.
1 in.
impurities
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
matrix
Millipore Express® SHC High Area
pore size
0.5/0.2 μm pore size
bubble point
≥4000 mbar (58 psig), air with water at 23 °C
fitting
1/4 in. drain/vent hose barb (with double O-ring seal), inlet sanitary flange, outlet hose barb, (38 mm (1 1/2 in.) Sanitary Flange Inlet and 25 mm (1 in.) Hose Barb Outlet)
application(s)
sample preparation
General description
Packaging
Preparation Note
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Analysis Note
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 42 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Other Notes
Legal Information
Disclaimer
Still not finding the right product?
Explore all of our products under Opticap® XLT 20 CapsuleMedia: Millipore Express® SHC High Area 0.5 / 0.2 µm
Emprove® 프로그램을 사용하여 GMP 준수 유지
Emprove® Dossiers로 자격을 가속화하고, 규정 준수를 유지하며, 시간을 절약하세요.
주: EmproveSuite.com으로 이동하게 됩니다. 귀하의 사용자 이름과 비밀번호는 시그마알드리치닷컴과는 별개이며 다를 수 있습니다.
무료로 등록하고 몇 분 안에 Emprove® Dossiers에 액세스하세요. 구독 플랜을 업그레이드하여 Emprove® Suite에서 고급 및 맞춤형 콘텐츠를 잠금 해제하세요.