크기 선택
제품정보 (DICE 배송 시 비용 별도)
InChI key
IMNFDUFMRHMDMM-UHFFFAOYSA-N
SMILES string
CCCCCCC
InChI
1S/C7H16/c1-3-5-7-6-4-2/h3-7H2,1-2H3
vapor density
3.5 (vs air)
vapor pressure
40 mmHg ( 20 °C), 83 mmHg ( 37.7 °C)
description
isocratic
product line
LiChrosolv®
assay
≥99.3% (GC)
form
liquid
autoignition temp.
433 °F
potency
>5000 mg/kg LD50, oral (Rat), >2000 mg/kg LD50, skin (Rabbit)
expl. lim.
7 %
greener alternative product characteristics
Safer Solvents and Auxiliaries
Learn more about the Principles of Green Chemistry.
sustainability
Greener Alternative Product
technique(s)
HPLC: suitable
impurities
≤0.0002 meq/g Acidity, ≤0.0002 meq/g Alkalinity, ≤0.005% Water
evapn. residue
≤2.0 mg/L
transmittance
210 nm, ≥50%, 220 nm, ≥80%, 245 nm, ≥98%
refractive index
n20/D 1.387 (lit.)
Quality Level
bp
98 °C (lit.)
mp
−91 °C (lit.)
transition temp
flash point -4 °C
solubility
0.05 g/L
density
0.684 g/mL at 25 °C (lit.)
greener alternative category
storage temp.
2-30°C
유사한 제품을 찾으십니까? 방문 제품 비교 안내
General description
Application
Also reported for use as a component of extraction mixture in screening drugs of abuse in urine samples by GC-MS.
Features and Benefits
- suitability tested and specified for UHPLC-MS and UHPLC-UV: for analytical flexibility
- specified quality in positive and negative electrospray ionization (ESI) and atmospheric-pressure chemical ionization-mass spectrometry (APCI-MS) for lowest detection limits and confidence in analyses in all important MS modes (test 1)
—ESI/APCI (-) < 10 ppb
- lowest impurity profile: for interference-free baselines (test 2)
- microfiltered through 0.2 μm filter (test 3) to provide:
—reduced risk of column clogging
- packaged in borosilicate glass bottles for minimized contamination with metal ions
- lowest levels of trace metal impurities to minimize metal ion adduct formation
- lowest level of polyethylene glycol (PEG) impurities in UHPLC-MS solvent lineup (PEG S/N signal-to-noise-ratio < 50)
Preparation Note
Analysis Note
Identity (IR): conforms
Evaporation residue: ≤ 2.0 mg/l
Water: ≤ 0.005 %
Acidity: ≤ 0.0002 meq/g
Alkalinity: ≤ 0.0002 meq/g
Transmission (at 210 nm): ≥ 50 %
Transmission (at 220 nm): ≥ 80 %
Transmission (from 245 nm): ≥ 98 %
Filtered by 0.2 µm filter
Other Notes
Legal Information
signalword
Danger
hcodes
Hazard Classifications
Aquatic Acute 1 - Aquatic Chronic 1 - Asp. Tox. 1 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3
target_organs
Respiratory system
저장 등급
3 - Flammable liquids
wgk
WGK 2
flash_point_f
24.8 °F - closed cup
flash_point_c
-4 °C - closed cup
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
문서
HPTLC separation followed by UV detection of the bitter acid content in various hop samples.
프로토콜
The modern thin-layer chromatography (TLC) offers advantages also in the field of cosmetics to quickly and simultaneously analyze samples with densitometric detection.
Thin layer chromatography coupled with mass spectrometry does not require substantial sample preparation. Energy drinks can be applied without dilution directly onto the TLC plate.
Qualitative Thin Layer Chromatography Analysis of Flavonoids and Quantification of Terpene Lactones in Ginkgo Biloba Extracts and Tablets
HPTLC was used to analyze caffeine in coffee. Filtration of coffee through a PTFE syringe filter was the only sample preparation. Quantitation was conducted with a TLC scanner.
국제 무역 품목 번호
| SKU | GTIN |
|---|---|
| 1.04390.1000 | 04022536051048 |
| 1.04390.2500 | 04022536051062 |
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.