biological source
mouse
Quality Segment
conjugate
FITC conjugate
antibody form
affinity isolated antibody
antibody product type
primary antibodies
clone
SM-phi, monoclonal
species reactivity
human
manufacturer/tradename
Chemicon®
technique(s)
flow cytometry: suitable, immunohistochemistry: suitable
isotype
IgM
NCBI accession no.
UniProt accession no.
shipped in
wet ice
target post-translational modification
unmodified
Gene Information
human ... CD36(948)
Immunogen
Human tonsil cells and peripheral blood mononuclear cells
Application
Research Category
Inflammation & Immunology
Inflammation & Immunology
Research Sub Category
Immunoglobulins & Immunology
Immunoglobulins & Immunology
Studies of platelet and monocyte receptor for thrombospondin
Studies of platelet collagen adhesion receptor
Flow cytometry
Optimal working dilutions must be determined by the end user.
Studies of platelet collagen adhesion receptor
Flow cytometry
Optimal working dilutions must be determined by the end user.
This Anti-CD36 Antibody, clone SM-phi, FITC conjugated is validated for use in FC, IH for the detection of CD36d. This antibody has been tested in Human.
Biochem/physiol Actions
This antibody recognizes the 90 kDa single chain membrane glycoprotein (GPIIIb) that is found on monocytes/macrophages and platelets. FUSION PARTNER: NS1 myeloma cell line
Physical form
The monoclonal was purified by affinity chromatography and gel filtration prior to conjugation. The conjugate is supplied in 1.0 ml of phosphate buffered saline containing 10mM sodium azide and 1mg/ml bovine serum albumin. For flow cytometry we recommend using 10μL of conjugate per test.
Preparation Note
Store at +4°C protected from light. DO NOT FREEZE. For long term use and storage aliquot conjugate into small volumes and store at +4°C for up to one year.
Legal Information
CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany
Disclaimer
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Still not finding the right product?
제품 선택 도구}를 사용하여 선택의 폭을 좁혀보세요.
저장 등급
12 - Non Combustible Liquids
wgk
WGK 2
flash_point_f
Not applicable
flash_point_c
Not applicable
시험 성적서(COA)