About This Item
species reactivity
human
manufacturer/tradename
Milliplex®
assay range
inter-assay cv: <15%
intra-assay cv: <10%
(C-Peptide), inter-assay cv: <15%
intra-assay cv: <10%
(GIP), inter-assay cv: <15%
intra-assay cv: <10%
(GLP-1 (Active)), inter-assay cv: <15%
intra-assay cv: <10%
(GLP-1 (Total)), inter-assay cv: <15%
intra-assay cv: <10%
(Ghrelin (Active)), inter-assay cv: <15%
intra-assay cv: <10%
(Glucagon), inter-assay cv: <15%
intra-assay cv: <10%
(IL-6), inter-assay cv: <15%
intra-assay cv: <10%
(Insulin), inter-assay cv: <15%
intra-assay cv: <10%
(Leptin), inter-assay cv: <15%
intra-assay cv: <10%
(MCP-1), inter-assay cv: <15%
intra-assay cv: <10%
(PP), inter-assay cv: <15%
intra-assay cv: <10%
(PYY), inter-assay cv: <15%
intra-assay cv: <10%
(TNFα), inter-assay cv: <20%
intra-assay cv: <10%
(Amylin (Active)), inter-assay cv: <20%
intra-assay cv: <10%
(Amylin (Total)), accuracy: 101%
(Glucagon), accuracy: 102%
(Leptin), accuracy: 103%
(GIP), accuracy: 103%
(GLP-1 (Total)), accuracy: 105%
(Ghrelin (Active)), accuracy: 106%
(MCP-1), accuracy: 97%
(TNFα), accuracy: 99%
(C-Peptide), sensitivity: 0.5 pg/mL
(MinDC+2SD; TNF?), sensitivity: 1.1 pg/mL
(MinDC+2SD; GIP), sensitivity: 13 pg/mL
(MinDC+2SD; IL-6), sensitivity: 14 pg/mL
(MinDC+2SD; Ghrelin (Active)), sensitivity: 14 pg/mL
(MinDC+2SD; MCP-1), sensitivity: 146 pg/mL
(MinDC+2SD; PYY), sensitivity: 15 pg/mL
(MinDC+2SD; Amylin (Total)), sensitivity: 16 pg/mL
(MinDC+2SD; C-Peptide), sensitivity: 16 pg/mL
(MinDC+2SD; Glucagon), sensitivity: 160 pg/mL
(MinDC+2SD; Insulin), sensitivity: 2.4 pg/mL
(MinDC+2SD; GLP-1 (Active)), sensitivity: 2.9 pg/mL
(MinDC+2SD; PP), sensitivity: 28 pg/mL
(MinDC+2SD; Amylin (Active)), sensitivity: 64 pg/mL
(MinDC+2SD; Leptin), sensitivity: 7.3 pg/mL
(MinDC+2SD; GLP-1 (Total)), standard curve range: 0.69-500 pg/mL
(TNFα), standard curve range: 1.4-1,000 pg/mL
(GIP), standard curve range: 13.7-10,000 pg/mL
(Amylin (Active)), standard curve range: 13.7-10,000 pg/mL
(Amylin (Total)), standard curve range: 13.7-10,000 pg/mL
(Ghrelin (Active)), standard curve range: 13.7-10,000 pg/mL
(Glucagon), standard curve range: 13.7-10,000 pg/mL
(IL-6), standard curve range: 13.7-10,000 pg/mL
(MCP-1), standard curve range: 13.7-10,000 pg/mL
(PYY), standard curve range: 137-100,000 pg/mL
(Insulin), standard curve range: 137-100,000 pg/mL
(Leptin), standard curve range: 2.7-2,000 pg/mL
(GLP-1 (Active)), standard curve range: 2.7-2,000 pg/mL
(GLP-1 (Total)), standard curve range: 2.7-2,000 pg/mL
(PP), standard curve range: 27.4-20,000 pg/mL
(C-Peptide)
technique(s)
multiplexing: suitable
detection method
fluorometric (Luminex xMAP)
shipped in
wet ice
General description
The MILLIPLEX® Human Metabolic Hormone Panel is a 15 analyte, 13-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma and cell/tissue culture samples: Amylin (Active) or Amylin (Total), C-Peptide, Ghrelin (Active), GIP, GLP-1 (Active) or GLP-1 (Total), Glucagon, IL-6, Insulin, Leptin, MCP-1, PP, PYY, TNFα. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Metabolism
Application
- Analytes: Amylin (Active), Amylin (Total), C-Peptide, Ghrelin (Active), GIP (Total), GLP-1 (Active), GLP-1 (Total), Glucagon, IL-6, Insulin, Leptin, MCP-1 (CCL2), Pancreatic Polypeptide (PP), PYY (Total), TNF-α
- NOTE: The following analytes cannot be assayed simultaneously: Amylin (Active) & Amylin (Total); GLP-1 (Active) & GLP-1 (Total).
- Recommended Sample Type: Human serum, plasma, and cell/tissue culture supernatants or lysates
- Recommended Sample Dilution: 25 μL per well of undiluted serum or plasma; cell/tissue culture samples may be used undiluted or diluted with an appropriate control medium NOTE: The following analytes require the addition of protease inhibitors to serum or plasma samples (see sample collection and storage section in the protocol for details): GLP-1 (DPPIV inhibitor); Amylin (protease inhibitor cocktail); Glucagon (Aprotinin); Ghrelin (Active) (serine protease inhibitor).
- Assay Run Time: Overnight (16-18 hours) at 2-8°C
- Research Category: Metabolism
- Research Subcategory: Metabolic Disorders
Features and Benefits
Other Notes
Legal Information
signalword
Danger
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Sens. 1
Storage Class
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
wgk
WGK 3
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.