Product Name
Poly(ethylene glycol) diacrylate, average Mn 6,000, contains ≤1500 ppm MEHQ as inhibitor
form
solid
Quality Level
mol wt
average Mn 6,000
contains
≤1500 ppm MEHQ as inhibitor
reaction suitability
reagent type: cross-linking reagent
reaction type: Polymerization Reactions
transition temp
Tm 59-63 °C
Ω-end
acrylate
α-end
acrylate
polymer architecture
shape: linear
functionality: homobifunctional
storage temp.
−20°C
SMILES string
OCCO.OC(=O)C=C
InChI
1S/C8H10O4/c1-3-7(9)11-5-6-12-8(10)4-2/h3-4H,1-2,5-6H2
InChI key
KUDUQBURMYMBIJ-UHFFFAOYSA-N
General description
Poly(ethylene glycol)diacrylate (PEGDA) is a long chain, hydrophilic and crosslinking monomer widelyused in tissue engineering.
Application
PEGDA is widely used as a scaffolding material for tissue engineering applications due to its biocompatibility and inherent resistance to protein adhesion.
It can be used as an alloying agent to prepare polymer membranes for gas separation applications. For example, an alloyed poly(Ether Block Amide)/ PEGDA membrane can be used for the separation of CO2/H2.
It can also be used as aprecursor to fabricate polymer electrolyte membranes(PEMs) for flexible Li-ionbatteries. The addition of PEGDA enhances the ionic conductivity, thermal stability,and mechanical toughness of PEMs.
It can be used as an alloying agent to prepare polymer membranes for gas separation applications. For example, an alloyed poly(Ether Block Amide)/ PEGDA membrane can be used for the separation of CO2/H2.
It can also be used as aprecursor to fabricate polymer electrolyte membranes(PEMs) for flexible Li-ionbatteries. The addition of PEGDA enhances the ionic conductivity, thermal stability,and mechanical toughness of PEMs.
Features and Benefits
- Highly hydrophilic
- Non-toxic
- Biocompatible
- Non-immunogenic
Still not finding the right product?
Explore all of our products under Poly(ethylene glycol) diacrylate
signalword
Danger
hcodes
Hazard Classifications
Eye Dam. 1 - Skin Irrit. 2 - Skin Sens. 1
Storage Class
11 - Combustible Solids
wgk
WGK 1
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
dust mask type N95 (US), Eyeshields, Faceshields, Gloves
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Shaun P Garland et al.
Langmuir : the ACS journal of surfaces and colloids, 30(8), 2101-2108 (2014-02-15)
A growing body of literature broadly documents that a wide array of fundamental cell behaviors are modulated by the physical attributes of the cellular microenvironment, yet in vitro assays are typically carried out using tissue culture plastic or glass substrates
Eyal Karzbrun et al.
Nature physics, 14(5), 515-522 (2018-05-16)
Human brain wrinkling has been implicated in neurodevelopmental disorders and yet its origins remain unknown. Polymer gel models suggest that wrinkling emerges spontaneously due to compression forces arising during differential swelling, but these ideas have not been tested in a
Adel Badria et al.
Journal of materials science. Materials in medicine, 29(11), 175-175 (2018-11-11)
Heart valve diseases remain common in industrialized countries. Bioprosthetic heart valves, introduced as free of anticoagulation therapy alternatives to mechanical substitutes. Still they suffer from long term failure due to calcification. Different treatment methods introduced to inhibit calcification, have so