Nom du produit
Opticap® XLT 30 Capsule Media: Millipore Express® SHR w/Prefilter 0.5 / 0.1 µm, Chemistry: Hydrophilic Polyethersulfone (PES)Inlet: 1-1/2 in. Sanitary FlangeOutlet: 1 in. Hose BarbT-lineMax Operating Pressure: 80psi @ 25 °C
Quality Segment
material
polypropylene device, polypropylene housing, polypropylene support, polypropylene vent cap, polysulfone device, silicone seal
reg. compliance
meets FDA 21 CFR 177-182 (all component materials)
sterility
non-sterile
sterilization compatibility
autoclavable compatible
product line
Opticap® XLT 30
feature
autoclavable, hydrophilic
manufacturer/tradename
Millipore Express®
parameter
≤81.3 mL/min air diffusion at 3.45 bar (50 psig) (in water), 1.0 bar max. differential pressure (15 psid) at 80 °C (Forward), 1.0 bar max. inlet pressure (15 psi) at 80 °C, 100 psi max. differential pressure (6.9 bar) (intermittent), 2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent), 2.75 bar max. inlet pressure (40 psi) at 60 °C, 25 °C max. inlet temp., 5.5 bar max. differential pressure (80 psid) at 25 °C (Forward), 5.5 bar max. inlet pressure (80 psi) at 23 °C, 6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent), 6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent), 80 psi max. differential pressure (5.5 bar) (continuous), 80 psig max. inlet pressure
technique(s)
sterile filtration: suitable
cartridge nominal length
30 in. (75 cm)
device L
87.1 cm (34.3 in.)
device size
30 in.
filter diam.
10.7 cm (4.2 in.)
filter filtration area
1.48 m2
impurities
≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction), <0.25 EU/mL USP bacterial endotoxins (sample aqueous extraction)
matrix
Millipore Express® SHR (w/Prefilter)
pore size
0.5/0.1 μm pore size
bubble point
≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water
fitting
(38 mm (1 ½ in.) Sanitary Flange Inlet and 25 mm (1 in.) Hose Barb Outlet)
General description
Packaging
Preparation Note
3 autoclave cycles of 60 min at 126 °C; not in-line steam sterilizable
Analysis Note
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Legal Information
Still not finding the right product?
Explore all of our products under Opticap® XLT 30 Capsule Media: Millipore Express® SHR w/Prefilter 0.5 / 0.1 µm
Restez en conformité avec les BPF grâce au programme Emprove®.
Accélérer la qualification, maintenir la conformité et gagner du temps avec Emprove® Dossiers.
Note: you will be brought to EmproveSuite.com. Your username and password are separate from SigmaAldrich.com and may differ.
Inscrivez-vous gratuitement et accédez à Emprove® Dossiers en quelques minutes. Mettez votre abonnement à niveau pour débloquer un contenu avancé et personnalisé dans la Emprove® Suite
Vous ne trouvez pas ce que vous cherchez ? Visitez la page d'aide du programme Emprove®..
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.