Accéder au contenu
Merck

E-015

Ethyl-β-D-glucuronide

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Se connecter pour consulter les tarifs organisationnels et contractuels.

Sélectionner une taille de conditionnement

Changer de vue

A propos de cet article

Formule empirique (notation de Hill) :
C8H14O7
Numéro CAS:
Poids moléculaire :
222.19
NACRES:
NA.24
PubChem Substance ID:
UNSPSC Code:
41116107
EC Number:
200-659-6
MDL number:
Service technique
Besoin d'aide ? Notre équipe de scientifiques expérimentés est là pour vous.
Laissez-nous vous aider


grade

certified reference material

Quality Level

form

liquid

feature

Snap-N-Spike®/Snap-N-Shoot®

packaging

ampule of 1 mL

manufacturer/tradename

Cerilliant®

concentration

1.0 mg/mL in methanol

technique(s)

gas chromatography (GC): suitable, liquid chromatography (LC): suitable

application(s)

forensics and toxicology

format

single component solution

storage temp.

−20°C

SMILES string

O[C@H]1[C@H](O)[C@@H](C(O)=O)O[C@@H](OCC)[C@@H]1O

InChI

1S/C8H14O7/c1-2-14-8-5(11)3(9)4(10)6(15-8)7(12)13/h3-6,8-11H,2H2,1H3,(H,12,13)/t3-,4-,5+,6-,8+/m0/s1

InChI key

IWJBVMJWSPZNJH-UQGZVRACSA-N

General description

This Certified Reference Material is widely used in forensic analysis and clinical toxicology applications to determine blood alcohol content.

Ethyl-β-D-glucuronide (EtG) is a water-soluble and stable metabolite of ethanol, used as a routine biomarker in alcohol abuse monitoring. A very small fraction of ethanol undergoes degradation to EtG, and it can be detected in body fluids as well as hair.

Application

The certified reference solution (CRM) in solution can also be used as follows:
  • Multi-residue analysis of different alcohol metabolites in human blood plasma and urine samples by ultra-high performance liquid chromatography (UHPLC) combined with tandem mass spectrometry (MS/MS)
  • Optimization of a supercritical fluid chromatography-tandem mass spectrometric (SFC-MS/MS) method for the separation and quantification of highly polar drugs and their metabolites using an ion-exchange stationary phase from human urine samples
  • Evaluation of a paired ion electrospray ionization mass spectrometric (PIESI-MS) approach coupled with high performance liquid chromatographic (HPLC) procedure for the detection and measurement of drug metabolites in urine samples
  • Assess the impact of sample preparation of hair samples on the quantitative analysis of ethyl-β-D-glucuronide by ultra-high performance liquid chromatography-electrospray ionization-tandem mass spectrometry
  • Analysis of ethyl-β-D-glucuronide as a urinary biomarker in human urine samples by a benchtop gas chromatograph coupled with a mass spectrometer (GC-MS)

Features and Benefits

  • Fully characterized under ISO/IEC 17025 and ISO 17034 accreditation
  • Accompanied with a comprehensive Certificate of Analysis (CoA) with data on stability, homogeneity, accuracy of concentration, uncertainty, and traceability
  • Rigorously tested through real-time stability studies to ensure accuracy and shelf life
  • Gravimetrically prepared using qualified precision balances to ensure minimal uncertainty
  • Flame sealed under argon into ampoules for long-term shelf life
  • Offered in a convenient, DEA-exempt format to improve laboratory efficiency

Legal Information

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany


Still not finding the right product?

Explore all of our products under


signalword

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

target_organs

Eyes

Classe de stockage

3 - Flammable liquids

wgk

WGK 1

flash_point_f

49.5 °F - closed cup

flash_point_c

9.7 °C - closed cup



Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents



Sensitive detection of anionic metabolites of drugs by positive ion mode HPLC-PIESI-MS
Guo H, et al.
International Journal of Mass Spectrometry, 389, 14-25 (2015)
A simplified approach for determination of urinary ethyl glucuronide by gas chromatography-mass spectrometry
Ghosh S, et al.
Journal of analytical science and technology, 12, 1-9 (2021)
Laurent Imbert et al.
Annales de biologie clinique, 70(6), 629-634 (2012-12-05)
Ethylglucuronide (EtG) is a biomarker of ethanol consumption, and the authors propose an overview of its potential use in clinical or forensic cases. This metabolite presents a higher half-life and is therefore detectable longer than ethanol itself, and allows, in