コンテンツへスキップ
Merck

CBA001

InnoZyme Cathepsin B Activity Assay Kit, Fluorogenic

別名:

Cathepsin B assay kit, Cathepsin activity assay

ログインで組織・契約価格をご覧ください。

サイズを選択してください

表示を変更する

この商品について

NACRES:
NA.84
UNSPSC Code:
41116133
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします


usage

sufficient for 96 tests

Quality Segment

packaging

pkg of 1 96-well plate(s)

manufacturer/tradename

Calbiochem®

storage condition

OK to freeze, avoid repeated freeze/thaw cycles, protect from light

assay range

sensitivity: 0.63 ng/mL, standard curve range: 0.09-100 ng/mL

input

sample type tissue
sample type cells

detection method

fluorometric

shipped in

wet ice

General description

A sensitive fluorogenic assay for the measurement of cathepsin B activity (Excitation max: ~360-380 nm; Emission max: ~430-460 nm). Cathepsin B is a cysteine proteinase which has been associated with increased invasivessness and development of the malignant cell phenotype. Cathepsin B has also been implicated in inflammatory airway disease.

Biochem/physiol Actions

<div class="Bio_doc_image">Table 3: Cross reactivity with others cathepsins
</div>
The Calbiochem Cathepsin B Activity Assay Kit, Fluorogenic is designed to measure cathepsin B activity in tissues extracts and cell lysates, and for screening cathepsin B inhibitors.



Note: Following initial use the control Cathepsin B should be dispensed into aliquots and stored at -20°C. Avoid freeze/thaw cycles

Features and Benefits

Assay Time: 30 min

Preparation Note

• Dilution Buffer: dilute assay buffer 1:10 with dH2OExample: add 0.5 ml of assay buffer to 4.5 ml of distilled water. • Standard: the free AMC standard is supplied as a 2 mM stock (100-fold concentrated) solution. To create a calibration curve prepare serial dilutions of the standard ranging from a concentration of 20 µM to a concentration of 1.25 µM. Example: label 6 eppendorf tubes. Pipet 495 µl of the dilution buffer into the first tube and 250 µl into the remaining tubes. Add 5 µl of the 2 mM AMC standard to the first tube. Vortex and transfer 250 µl from this tube to the next tube. Continue serial dilutions by transferring 250 µl up to tube #5. The tube labeled #6 will contain dilution buffer only (blank).• Substrate Working Solution: substrate should be diluted 100 times with distilled water. Example: to prepare 2 ml of substrate solution add 20 µl of the substrate stock solution to 1.98 ml of distilled water. • Activation Buffer: cysteine is supplied as a 250-fold concentrated reagent. To prepare activation buffer 8 µl of 1 M cysteine should be added to 2 ml of the supplied assay buffer (this is enough for half of the plate). • Inhibitor: CA-074 inhibitor is supplied as a 10-fold stock solution and should be diluted with activation buffer. Example: dilute 10 µl of the stock solution with 90 µl of the activation buffer to yield 100 µl of working solution.• Control: dilute the control human cathepsin B with dilution buffer as directed on the vial label. The cathepsin B enzyme should be dispensed into aliquots and stored at -70°C to maintain activity.
Dilute samples with dilution buffer as necessary. Note: if the measured FU exceeds 9,000 the sample should be diluted further. • Cell lysate: wash cell pellet with ice-cold PBS. Add 500-1000 µl of cell lysis buffer (~1 ml per 1x107 cells) and incubate on ice for 30 min. Vortex and centrifuge the lysate at 14,000 x g in a pre-cooled tabletop microcentrifuge. Immediately transfer the supernatant to a fresh microcentrifuge tube and discard the pellet. Dilute the lysate 1:5 or 1:10 before determining the protein concentration via BCA protein assay.
Store the unopened components at -20°C and -70°C as indicated on the labels. All kit components, once opened, can be stored under the following conditions:



Assay Buffer, Cell Lysis Buffer, 96-Well Plate, and Plate Sealers at Room Temperature



Cathepsin B Inhibitor, Reduction Reagent, Cathepsin B Substrate, and Calibration Standard at -20°C



Control Cathepsin B(aliquot) at -70°C

Analysis Note

Positive Control
Cathepsin B
The data obtained can be displayed in two ways:1. As fluorescence units: correct the fluorescence value of all samples by subtracting the value of the blank, and then calculate the mean fluorescence value for each sample in duplicate. For the biological samples also subtract the value of the sample assayed with inhibitor.OR2. As µmole of free AMC/mg total protein/time (min.): calculate the mean fluorescence value as stated above. Plot a graph correlating the mean fluorescence values of the AMC standards (y-axis) to their concentration in µmole (x-axis). The cathepsin B activity of the unknown samples can be interpolated from the standard curve.Calculate the amount (µmol) of free AMC per mg of total protein and time unit.

Other Notes

Bervar, A., et al. 2003. Biol. Chem. 384, 447.
Grigolo, B. et al. 2003. Biomaterials 24, 1751.
Scolaris, A., et al. 2002. Biol. Chem. 383, 1297.
Murata, M., et al. 1991. FEBS Lett. 280, 307.
Berquin, I.M. and Sloane, B.F. 1996. Adv. Exp. Med. Biol. 389, 281.
Burnett, D., 1995. Arch. Biochem. Biophys. 317, 305.
Reddy, V.Y., et al. 1995. Proc. Natl. Acad. Sci. 92, 3849.
Buttle, D.J., 1994. In: Immunopharmacology of Joints and Connective Tissue (Dingle, J.T. and Davies, M.E., eds) London: Academic Press. 225.
Barrett, A.J. and Kirschke, H., 1981. Methods Enzymol. 80, 535.
Cathepsin B Enzyme, Calibration Standard, Cathepsin B Substrate, Assay Buffer, Cathepsin B Inhibitor, Reduction Reagent, Cell Lysis Buffer, Microtiter Plate, Plate Sealer, and a user protocol.

Legal Information

CALBIOCHEM is a registered trademark of Merck KGaA, Darmstadt, Germany

Disclaimer

Toxicity: Multiple Toxicity Values, refer to MSDS (O)


保管分類

10 - Combustible liquids

wgk

WGK 3


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

Please refer to KIT Component information

pdsc

Please refer to KIT Component information

prtr

Please refer to KIT Component information

fsl

Please refer to KIT Component information

ishl_indicated

Please refer to KIT Component information

ishl_notified

Please refer to KIT Component information

cart

キットコンポーネントの情報を参照してください

jan



試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする