Skip to Content
Merck
  • Liquid chromatography tandem mass spectrometry determination of selected synthetic cathinones and two piperazines in oral fluid. Cross reactivity study with an on-site immunoassay device.

Liquid chromatography tandem mass spectrometry determination of selected synthetic cathinones and two piperazines in oral fluid. Cross reactivity study with an on-site immunoassay device.

Journal of chromatography. A (2014-12-09)
Ana de Castro, Elena Lendoiro, Hadriana Fernández-Vega, Stefan Steinmeyer, Manuel López-Rivadulla, Angelines Cruz
ABSTRACT

Since the past few years, several synthetic cathinones and piperazines have been introduced into the drug market to substitute illegal stimulant drugs such as amphetamine and derivatives or cocaine due to their unregulated situation. These emerging drugs are not usually included in routine toxicological analysis. We developed and validated a LC-MS/MS method for the determination of methedrone, methylone, mephedrone, 3,4-methylenedioxypyrovalerone (MDPV), fluoromethcathinone, fluoromethamphetamine, 1-(3-chlorophenyl)piperazine (mCPP) and 3-trifluoromethylphenylpiperazine (TFMPP) in oral fluid. Sample extraction was performed using Strata X cartridges. Chromatographic separation was achieved in 10min using an Atlantis(®) T3 column (100mm×2.1mm, 3μm), and formic acid 0.1% and acetonitrile as mobile phase. The method was satisfactorily validated, including selectivity, linearity (0.2-0.5 to 200ng/mL), limits of detection (0.025-0.1ng/mL) and quantification (0.2-0.5ng/mL), imprecision and accuracy in neat oral fluid (%CV=0.0-12.7% and 84.8-103.6% of target concentration, respectively) and in oral fluid mixed with Quantisal™ buffer (%CV=7.2-10.3% and 80.2-106.5% of target concentration, respectively), matrix effect in neat oral fluid (-11.6 to 399.7%) and in oral fluid with Quantisal™ buffer (-69.9 to 131.2%), extraction recovery (87.9-134.3%) and recovery from the Quantisal™ (79.6-107.7%), dilution integrity (75-99% of target concentration) and stability at different conditions (-14.8 to 30.8% loss). In addition, cross reactivity produced by the studied synthetic cathinones in oral fluid using the Dräger DrugTest 5000 was assessed. All the analytes produced a methamphetamine positive result at high concentrations (100 or 10μg/mL), and fluoromethamphetamine also at low concentration (0.075μg/mL).

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (w/v) ammonium formate, 5 % (v/v) water, 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Ammonia-14N, 99.99 atom % 14N
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrile solution, contains 0.05 % (v/v) trifluoroacetic acid
Sigma-Aldrich
Acetonitrile solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
Sodium hydroxide, ultra dry, powder or crystals, 99.99% trace metals basis
Sigma-Aldrich
Potassium chloride solution, 0.075 M, sterile-filtered, BioXtra, suitable for cell culture
Supelco
Methanol, analytical standard
Sigma-Aldrich
Potassium chloride, powder, BioReagent, suitable for cell culture, suitable for insect cell culture, ≥99.0%
Sigma-Aldrich
Potassium chloride, Molecular Biology, ≥99.0%
Sigma-Aldrich
Potassium chloride, AnhydroBeads, −10 mesh, 99.99% trace metals basis
Sigma-Aldrich
Potassium chloride, AnhydroBeads, −10 mesh, 99.999% trace metals basis
Sigma-Aldrich
3-Ethyl-2,4-pentanedione, mixture of tautomers, 98%
Sigma-Aldrich
Isopropyl alcohol, ≥99.7%, FCC, FG
Sigma-Aldrich
Boric acid-11B, ≥99 atom % 11B
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Potassium chloride, ≥99.99% trace metals basis
Sigma-Aldrich
Potassium chloride, 99.999% trace metals basis
Supelco
ISA (ionic strength adjustment solution: 1 M KCl), 1 M KCl
Supelco
Sodium hydroxide solution, 49-51% in water, eluent for IC
Sigma-Aldrich
Sodium hydroxide, BioUltra, suitable for luminescence, ≥98.0% (T), pellets
Sigma-Aldrich
Potassium chloride solution, BioUltra, Molecular Biology, ~1 M in H2O
Supelco
Potassium chloride solution, conductance standard C acc. to ISO 7888, 0.001 M KCl
Supelco
Potassium chloride solution, BioUltra, ~3 M in H2O
Supelco
Potassium chloride solution, ~3 M KCl, saturated with silver chloride
Sigma-Aldrich
Potassium chloride, BioUltra, Molecular Biology, ≥99.5% (AT)
Sigma-Aldrich
Potassium chloride, tested according to Ph. Eur.
Supelco
Potassium chloride solution, conductance standard A acc. to ISO 7888, 0.1 M KCl
Sigma-Aldrich
Sodium hydroxide solution, BioUltra, Molecular Biology, 10 M in H2O