| What is the typical hold-up (non-recoverable) volume of the Steripak-GP? | The typical hold-up volume for Steripak-GP is 2.7 mL after air purge. | 
| Which pump should I use with Steripak-GP? | Millipore recommends use of a pump that can generate a flow rate of approximately 100 mL / min. | 
| What is the pressure limit for Steripak-GP? | The pressure limit at 25 degrees C is 75 psig. | 
| Can I resterilize and reuse the Steripak-GP? | The Steripak-GP is a single use device and is not autoclavable. | 
| Is the Express membrane surfactant free? | Yes, the Express membrane is surfactant free. It also has a very low extractables specification - less then 1.5% by weight. | 
Related Products & Applications
Related Products By: Application Facete
| Sample Preparation | 
| Dialysis and Filtration | 
Related Products By: Brand Facete
| Steripak™ | 
Categories
| Life Science Research > Cell Culture and Systems > Sterile Filtration Devices | 
Steripak-GP filter units are designed for larger scale pressure-driven filtration of tissue culture media with or without serum. They are single use and are not autoclavable. The filter units come in two sizes, with the smaller unit able to filter up to 10 L and the larger up to 20 L. Both sizes utilize the low protein binding, fast flow 0.22 µm Millipore Express membrane. Each unit has an integral filling bell for bottle-top use and a manually operated upstream air vent to prevent membrane air locking. They are supplied sterile and ready to connect to a pump or pressure vessel (not included).
Steripak™-GP filter units are designed for larger scale, pressure-driven filtration of tissue culture media with or without serum. Each filter is for a single use and is not autoclavable. The filter units come in two sizes with the smaller unit able to filter up to 10 L and the larger up to 20 L.
Features & Benefits
- Millipore Express® PLUS membrane for fastest flow rates and low protein binding 
- Larger scale, pressure-driven filtration device for faster flow rates speeds time-consuming, large-volume filtrations 
- 10 L and 20 L capacity sizes for maximum laboratory-scale filtration options 
- Manually operated top air vent to prevent air lock stop of flow 
- Filling bell for cleaner filling environment around the opening of the receptacle bottle
Applications
Sterilization of Aqueous Solutions, Media Preparation, Buffer Preparation
Product Performance
| Materials of Construction | |
| Housing | SAN | 
| Membrane | Polyethersulfone (PES) | 
| Inlet Connection | 6 mm (1/4 in.) stepped Hose Barb | 
| Outlet Fittings | 6 mm (1/4 in.) stepped Hose Barb and filling bell | 
| Pressure, bar (psi) | Forward: 5.2 bar (75 psi); Reverse: 0.35 bar (5 psi) | 

 


 
  

 
 
 