제품 이름
Hydrochloric acid solution, 32% EMPLURA®
SMILES string
Cl
InChI
1S/ClH/h1H
InChI key
VEXZGXHMUGYJMC-UHFFFAOYSA-N
vapor pressure
21.3 hPa ( 20 °C)
product line
EMPLURA®
assay
≥32% (alkalimetric)
form
liquid
impurities
≤0.0001% As (Arsenic)
≤0.0001% Free chlorine (Cl)
≤0.0001% Heavy metals (as Pb)
≤0.0002% Fe (Iron)
≤0.0005% Sulfate (SO4)
≤0.001% Sulfite (SO?)
pH
<1 (20 °C in H2O)
mp
-50 °C
density
1.16 g/cm3 at 20 °C
storage temp.
15-25°C
Quality Level
유사한 제품을 찾으십니까? 방문 제품 비교 안내
관련 카테고리
Analysis Note
Assay (alkalimetric): ≥ 32 %
Identity: passes test
Bromide, Iodide (Br,I): passes test
Free chlorine (Cl): ≤ 0.0001 %
Sulfate (SO₄): ≤ 0.0005 %
Sulfite (SO₃): ≤ 0.001 %
Heavy metals (as Pb): ≤ 0.0001 %
As (Arsenic): ≤ 0.0001 %
Fe (Iron): ≤ 0.0002 %
Residual solvents (ICH Q3C): ...excluded by production process
Evaporation residue: ≤ 0,01
Expiry date : see product label
Identity: passes test
Bromide, Iodide (Br,I): passes test
Free chlorine (Cl): ≤ 0.0001 %
Sulfate (SO₄): ≤ 0.0005 %
Sulfite (SO₃): ≤ 0.001 %
Heavy metals (as Pb): ≤ 0.0001 %
As (Arsenic): ≤ 0.0001 %
Fe (Iron): ≤ 0.0002 %
Residual solvents (ICH Q3C): ...excluded by production process
Evaporation residue: ≤ 0,01
Expiry date : see product label
Application
- Research on the Synthesis of Zinc-Ammonium Phosphate Using Galvanic Waste Sludge as a Source of Zinc: This study explores a novel approach using hydrochloric acid solution in the synthesis process aimed at valorizing waste materials. The article demonstrates a chemical strategy that enhances resource recovery, significantly contributing to waste minimization in industrial practices (Morgovan et al., 2024).
- Contactless conductivity sensor employing moist paper as absorbent for in-situ detection of generated carbon dioxide gas: The study integrates hydrochloric acid solutions in the development of a novel, cost-effective contactless conductivity sensor. This sensor uses a simple paper-based system for the in-situ monitoring of gases, providing a significant tool in environmental monitoring and analysis (Nacapricha et al., 2020).
Legal Information
EMPLURA is a registered trademark of Merck KGaA, Darmstadt, Germany
signalword
Danger
hcodes
Hazard Classifications
Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1B - STOT SE 3
target_organs
Respiratory system
저장 등급
8B - Non-combustible, corrosive hazardous materials
wgk
WGK 1
flash_point_f
Not applicable
flash_point_c
Not applicable
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
국제 무역 품목 번호
| SKU | GTIN |
|---|---|
| 1.00313.2500 | 04022536004303 |
| 1.00313.9025 | 04022536004327 |
| 1.00313.9180 | 04022536004334 |
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.