Iniciar sesión para ver los precios por organización y contrato.
Seleccione un Tamaño
Cambiar Vistas
Acerca de este artículo
Fórmula lineal:
CH3(CH2)6COOH
Número CAS:
Peso molecular:
144.21
PubChem Substance ID:
UNSPSC Code:
12352106
Beilstein/REAXYS Number:
1747180
MDL number:
Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarlevapor density
5 (vs air)
vapor pressure
1 mmHg ( 78 °C)
assay
≥96.0%
availability
available only in Japan
refractive index
n20/D 1.428 (lit.)
bp
237 °C (lit.)
mp
15-17 °C (lit.)
density
0.91 g/mL at 25 °C (lit.)
functional group
carboxylic acid
storage temp.
room temp
SMILES string
CCCCCCCC(O)=O
InChI
1S/C8H16O2/c1-2-3-4-5-6-7-8(9)10/h2-7H2,1H3,(H,9,10)
InChI key
WWZKQHOCKIZLMA-UHFFFAOYSA-N
Application
amino acid analysis
Still not finding the right product?
Explore all of our products under Ácido octanoico
signalword
Danger
hcodes
Hazard Classifications
Aquatic Chronic 3 - Eye Dam. 1 - Skin Corr. 1C
Clase de almacenamiento
8A - Combustible corrosive hazardous materials
wgk
WGK 1
flash_point_f
>230.0 °F - closed cup
flash_point_c
> 110 °C - closed cup
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Romain Harmancey et al.
FASEB journal : official publication of the Federation of American Societies for Experimental Biology, 27(10), 3966-3978 (2013-07-05)
Diabetic patients with acute myocardial infarction are more likely to die than nondiabetic patients. In the present study we examined the effect of insulin resistance on myocardial ischemia tolerance. Hearts of rats, rendered insulin resistant by high-sucrose feeding, were subjected
Hong-Fei Tong et al.
Journal of chromatography. A, 1285, 88-96 (2013-03-12)
Hydrophobic charge-induction chromatography (HCIC) is a novel downstream bioprocessing technology for antibody purification and it has several advantages over traditional purification processes. However, its separation selectivity still needs to be improved. In this work, sodium caprylate (NaCA) was used as
K M Morrill et al.
Journal of dairy science, 95(7), 3987-3996 (2012-06-23)
Our objectives were to evaluate the use of refractometry as a means of estimating immunoglobulin G (IgG) concentration of bovine maternal colostrum (MC) and determine if fractionation of MC using caprylic acid (CA) improved estimates of IgG. Samples (n=85) of
