Seleccione un Tamaño
Acerca de este artículo
Nombre del producto
FIBRONECTINA DEL PLASMA HUMANO, liquid, 0.1% (Solution), BioReagent, suitable for cell culture
biological source
human plasma
sterility
sterile
product line
BioReagent
form
liquid
packaging
pkg of 1 mg
pkg of 2 mg
pkg of 5 mg
concentration
0.1% (Solution)
technique(s)
cell culture | mammalian: suitable
surface coverage
1‑5 μg/cm2
solubility
saline: 0.05 M (Tris-buffered)
UniProt accession no.
binding specificity
Peptide Source: Collagen
shipped in
wet ice
storage temp.
2-8°C
Quality Level
Gene Information
human ... FN1(2335)
¿Está buscando productos similares? Visita Guía de comparación de productos
Categorías relacionadas
Analysis Note
Application
Biochem/physiol Actions
Disclaimer
Features and Benefits
- Glucoproteína adhesiva
- Derivada del plasma humano
- Cobertura de superficie recomendada de 1-5 μg/cm2
General description
La FN aparece como un dímero proteico, unido por dos enlaces disulfuro en el extremo C-terminal. Dentro de la estructura de la fibronectina, los dominios están dispuestos de forma compacta cerca de los extremos amino y carboxilo terminales de las cadenas peptídicas. Además, pese a proceder de un solo gen, en humanos se han identificado hasta 20 variantes distintas de este gen.
Preparation Note
En el recubrimiento de las superficies de cultivo, la fibronectina debe diluirse en disolución salina estéril equilibrada y recubrirse con un volumen mínimo. Luego hay que dejar secar la superficie al aire durante 45 minutos a temperatura ambiente y puede conservarse durante 2-4 semanas a 2-8°C
Legal Information
Clase de almacenamiento
12 - Non Combustible Liquids
wgk
WGK 1
flash_point_f
Not applicable
flash_point_c
Not applicable
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Which document(s) contains shelf-life or expiration date information for a given product?
If available for a given product, the recommended re-test date or the expiration date can be found on the Certificate of Analysis.
How do I get lot-specific information or a Certificate of Analysis?
The lot specific COA document can be found by entering the lot number above under the "Documents" section.
How should I store and handle Product F0895, Fibronectin from human plasma?
Recommended storage of this material is 2-8 °C. Vortexing, excessive agitation, repeated freezing and thawing of reconstituted fibronectin are not recommended.
Is Product F0895, Fibronectin from human plasma, sterile?
Fibronectin 0.1% solution is a sterile product. It is tested for sterility. The sterility test results can be found on the lot-specific certificate of analysis.
What is the solvent for Product F0895, Fibronectin from human plasma?
This material is solubilized in a 0.05 M Tris-buffered saline, pH 7.5.
How much Product F0895, Fibronectin from human plasma, do I use for my application?
Recommended for use as a cell culture substratum at 1-5 μg/cm2 or 0.5-50 μg/mL. Optimal concentration depends on cell type as well as the application or research objectives.
How do I find price and availability?
There are several ways to find pricing and availability for our products. Once you log onto our website, you will find the price and availability displayed on the product detail page. You can contact any of our Customer Sales and Service offices to receive a quote. USA customers: 1-800-325-3010 or view local office numbers.
What is the Department of Transportation shipping information for this product?
Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.
My question is not addressed here, how can I contact Technical Service for assistance?
Ask a Scientist here.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico