Accéder au contenu
Merck

L6669

LuminoCt® qPCR ReadyMix

For fast probe-based quantitative PCR

Synonyme(s) :

LuminoCt® qPCR ReadyMix, LuminoCt®

Se connecter pour consulter les tarifs organisationnels et contractuels.

Sélectionner une taille de conditionnement


A propos de cet article

NACRES:
NA.55
UNSPSC Code:
41106300
Service technique
Besoin d'aide ? Notre équipe de scientifiques expérimentés est là pour vous.
Laissez-nous vous aider
Service technique
Besoin d'aide ? Notre équipe de scientifiques expérimentés est là pour vous.
Laissez-nous vous aider

form

liquid

usage

sufficient for 100 reactions, sufficient for 2000 reactions, sufficient for 500 reactions

feature

dNTPs included, hotstart

Quality Level

technique(s)

RT-qPCR: suitable, qPCR: suitable

color

colorless

input

purified DNA

suitability

suitable for (quantitative PCR)

application(s)

agriculture

compatibility

Bio-Rad MyiQ ( ), Bio-Rad iCycler iQ, Bio-Rad iQ 5, for use with ABI 5700, for use with ABI 7000, for use with ABI 7300, for use with ABI 7500 Fast, for use with ABI 7500, for use with ABI 7700, for use with ABI 7900 Fast, for use with ABI 7900 HT, for use with ABI 7900, for use with ABI StepOne, for use with ABI StepOnePlus, for use with ABI ViiA 7, for use with Bio-Rad CFX384, for use with Bio-Rad CFX96, for use with Bio-Rad MJ Chromo4, for use with Bio-Rad MJ Opticon 2, for use with Bio-Rad MJ Opticon Cepheid SmartCycler, for use with Bio-Rad MJ Opticon, for use with Bio-Rad MiniOpticon, for use with Eppendorf® Mastercycler ep realplex2 s, for use with Eppendorf® Mastercycler ep realplex, for use with Illumina Eco qPCR, for use with Qiagen Corbett Rotor-Gene 3000, for use with Qiagen Corbett Rotor-Gene 6000, for use with Qiagen Corbett Rotor-Gene Q, for use with Roche LightCycler 480, for use with Strategene Mx3000P, for use with Strategene Mx3005P, for use with Strategene Mx4000

detection method

probe-based

shipped in

wet ice

storage temp.

−20°C

Application

LuminoCt® qPCR ReadyMix has been used in 2-step quantitative reverse transcription polymerase chain reaction (qRT-PCR) assay to quantify the reverse transcription product or cDNA for gene expression analysis. It has also been used in qPCR for quantifying the RNA extracted from rhinoviruses.

Features and Benefits

  • Assay results in as little as 25 minutes
  • Designed to deliver unsurpassed accuracy, precision, and sensitivity
  • Extensive design and validation of ReadyMix chemistry virtually eliminates the need to optimize assay parameters
  • Ideal for rapid, high-throughput 2-step qPCR protocols
  • The master mix allows consistency and reproducibility from one reaction to the next
  • Reduced preparation time and the risk of contamination from multiple pipetting steps
  • Compatible with commonly available real-time instrument platforms for probe-based qPCR assays
  • Require small amplicons (<200 bp) for optimal results
  • Compatible with commercial primer sets, including TaqMan® assays
  • JumpStart Taq DNA polymerase allows room temperature set-up and the hot-start mechanism prevents primer-dimer and non-specific product formation

General description

Inclusion of JumpStart Taq antibody in the ReadyMix eliminates polymerase activity at ambient temperatures without causing the performance issues associated with chemically modified hot-start Taq. This allows for very rapid activation of the Taq and delivers unparalleled assay sensitivity, while allowing for benchtop reaction setup.

  • Kit is designed to perform probe-based qPCR assays on commonly available real-time instrument platforms.
  • ReadyMix requires the addition of reference dye (provided in kit) when being used on real-time instruments that require ROX passive reference dye for normalization of qPCR assays.
  • Kit is not compatible with qPCR instruments that utilize glass capillary tubes.
LuminoCt® qPCR ReadyMix combines the performance enhancements of our JumpStart Taq antibody for hot start PCR with the convenience of an easy-to-use reaction mixture.

Other Notes

  • Commercially available 5′ nuclease assays (e.g., TaqMan® Assays) are compatible with LuminoCt ReadyMix.
  • At a minimum, use software to design primers and probes for assays and ensure that qPCR amplicons are <200 bp.
  • Sigma recommends designing primers and probes with Beacon Designer software

To order primers and probes from Sigma, visit www.sigma.com/oligos

Packaging

LuminoCt qPCR ReadyMix, Catalog Number L5794, contains optimized concentrations of Tris-HCl, pH 8.3, KCl, dNTPs (dATP, dCTP, dGTP, TTP), stabilizers, MgCl2 and JumpStart Taq DNA Polymerase. Provided as 100, 500 and 2000 reactions (25 μL mix in a 50 μL reaction volume).

100x ROX internal reference dye, Catalog Number R4526. Optional, for use with machines compatible with an internal reference dye, e.g., ABI and Stratagene.

Default reaction volume is 50 μL

100RXN is packaged as 1 X 2.5 mL
500RXN is packaged as 1 X 12.5 mL
2000RXN is packaged as 1 X 50 mL

Legal Information

Eppendorf is a registered trademark of Eppendorf SE
JumpStart is a trademark of Sigma-Aldrich Co. LLC
LuminoCt is a registered trademark of Merck KGaA, Darmstadt, Germany
ReadyMix is a trademark of Sigma-Aldrich Co. LLC
TaqMan is a registered trademark of Roche Molecular Systems, Inc.

Composants de kit également disponibles séparément

Réf. du produit
Description
FDS

  • R4526100X ROX internal reference dyeFDS

Classe de stockage

10 - Combustible liquids

wgk

WGK 1


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Samer M Hussein et al.
Nature, 471(7336), 58-62 (2011-03-04)
The mechanisms underlying the low efficiency of reprogramming somatic cells into induced pluripotent stem (iPS) cells are poorly understood. There is a clear need to study whether the reprogramming process itself compromises genomic integrity and, through this, the efficiency of
Laura de Diego-García et al.
Biochimica et biophysica acta. Molecular basis of disease, 1863(1), 43-51 (2016-10-22)
The Ubiquitin-Proteasome System (UPS) is essential for the regulation of the cellular proteostasis. Indeed, it has been postulated that an UPS dysregulation is the common mechanism that underlies several neurological disorders. Considering that extracellular nucleotides, through their selective P2Y2 receptor
Philip Owens et al.
PloS one, 8(6), e67533-e67533 (2013-07-11)
Bone Morphogenetic Proteins (BMPs) are secreted cytokines that are part of the Transforming Growth Factor β (TGFβ) superfamily. BMPs have been shown to be highly expressed in human breast cancers, and loss of BMP signaling in mammary carcinomas has been
Talita B Gagliardi et al.
PLoS pathogens, 18(1), e1010159-e1010159 (2022-01-08)
The clinical impact of rhinovirus C (RV-C) is well-documented; yet, the viral life cycle remains poorly defined. Thus, we characterized RV-C15 replication at the single-cell level and its impact on the human airway epithelium (HAE) using a physiologically-relevant in vitro
Juan Vicente Canet et al.
The Plant cell, 24(10), 4220-4235 (2012-10-16)
Salicylic acid (SA) signaling acts in defense and plant development. The only gene demonstrated to be required for the response to SA is Arabidopsis thaliana non-expresser of pathogenesis-related gene 1 (NPR1), and npr1 mutants are insensitive to SA. By focusing

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique