Skip to Content
Merck

CX0395

Carbon Disulfide

Meets ACS Specifications, Meets Reagent Specifications for testing USP/NF monographs GR ACS

Synonym(s):

Carbon Disulfide, Carbon Bisulfide

Sign In to View Organizational & Contract Pricing.

Select a Size



About This Item

Empirical Formula (Hill Notation):
CS2
CAS Number:
Molecular Weight:
76.14
UNSPSC Code:
12191602
EC Index Number:
200-843-6
MDL number:
assay:
≥99.9% (GC)
bp:
46.5 °C/1013 hPa
vapor pressure:
398 hPa ( 20 °C)

Product Name

Carbon Disulfide, Meets ACS Specifications, Meets Reagent Specifications for testing USP/NF monographs GR ACS

SMILES string

S=C=S

InChI

1S/CS2/c2-1-3

InChI key

QGJOPFRUJISHPQ-UHFFFAOYSA-N

agency

meets USP/NF

vapor pressure

398 hPa ( 20 °C)

assay

≥99.9% (GC)

form

liquid

dilution

(for analytical testing)

impurities

≤0.05% Water (H2O)

evapn. residue

≤0.002%

color

APHA: ≤10

bp

46.5 °C/1013 hPa

mp

-111.6 °C

transition temp

flash point -30 °C

solubility

2.1 g/L

density

1.26 g/cm3 at 20 °C

shipped in

ambient

storage temp.

room temp

Quality Level

Looking for similar products? Visit Product Comparison Guide

Analysis Note

Assay (GC): 99.9% min
Color (APHA): 10 max
Evaporation residue: 0.002% max
Form: Clear liquid
Hydrogen sulfide (H2S): To pass test (about 1.5 ppm)
Sulfur dioxide (SO2): To pass test (about 2.5 ppm)
Water (H2O): 0.05% max

Application

CX0395-6 and CX0395-5 are packaged in poly coated glass bottles
Meets ACS Specifications, Meets Reagent Specifications for testing USP/NF monographs GR ACS

General description

EMPARTA solvents are designed for routine chemical synthesis, drying, purification, and critical labware cleaning in quality control environments. Engineered for precision, they deliver consistently reproducible results essential for rigorous validation and documentation.

Exceptional Quality Standards: These solvents meet or exceed ACS specifications, providing assurance of high quality that is crucial for accurate testing and analysis in quality control.

Consistent Reproducibility: Designed for precision, the solvents ensure that results can be reliably reproduced, which is vital for maintaining compliance and integrity in quality control processes.

Versatile Applications: Suitable for a variety of QC tasks, including analytical testing, method validation, and testing USP/NF monographs, these solvents support a comprehensive approach to quality assurance in laboratory settings.

signalword

Danger

Hazard Classifications

Acute Tox. 4 Inhalation - Eye Irrit. 2 - Flam. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 1

target_organs

Peripheral nervous system,Central nervous system,Cardio-vascular system,Eyes

Storage Class

3 - Flammable liquids

wgk

WGK 2

flash_point_f

-22.0 °F - closed cup

flash_point_c

-30 °C - closed cup


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service