About This Item
Specific activity:
≥5.0 units/mg solid
Looking for similar products? Visit Product Comparison Guide
General description
Glutamate is a non-essential amino acid. It acts as a primary excitatory neurotransmitter. In major trauma, major surgery, sepsis and bone marrow transplantation, glutamate functions as an essential amino acid.
Application
L-Glutamate Oxidase from Streptomyces sp has been used to determine the enzyme activity of the immobilized glutamate oxidase (GOx). It has also been used as a component of imaging buffer for stochastic optical reconstruction microscopy (STORM) imaging.
Biochem/physiol Actions
L-glutamate oxidase catalyzes the conversion of L-glutamate to 2-oxoglutarate.
Major enzyme in the synthesis or degradation of glutamic acid; transfers an amine to α-ketoglutaric acid to form L-glutamic acid or deamidates L-glutamic acid
Other Notes
One unit will form 1.0 μmole of α-ketoglutaric acid from L-glutamic acid per min at pH 7.4 at 30 °C.
Storage Class
11 - Combustible Solids
wgk
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
Eyeshields, Gloves, type N95 (US)
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Purification and properties of a new enzyme, L-glutamate oxidase, from Streptomyces sp X-119-6 grown on wheat bran.
H. Yoshino
Agricultural and Biological Chemistry, 74, 1323-1328 (1983)
Sensing based on the motion of enzyme-modified nanorods
Bunea AI, et al.
Biosensors And Bioelectronics, 67(9), 42-48 (2015)
II. Glutamine and glutamate
Tapiero H, et al.
Biomedicine and Pharmacotherapy, 56(9), 446-457 (2002)
Control of the oxygen dependence of an implantable polymer/enzyme composite biosensor for glutamate.
Colm P McMahon et al.
Analytical chemistry, 78(7), 2352-2359 (2006-04-04)
Biosensors for glutamate (Glu) were fabricated from Teflon-coated Pt wire (cylinders and disks), modified with the enzyme glutamate oxidase (GluOx) and electrosynthesized polymer PPD, poly(o-phenylenediamine). The polymer/enzyme layer was deposited in two configurations: enzyme before polymer (GluOx/PPD) and enzyme after
Colm P McMahon et al.
Biosensors & bioelectronics, 22(7), 1466-1473 (2006-08-05)
Biosensors were fabricated at neutral pH by sequentially depositing the polycation polyethyleneimine (PEI), the stereoselective enzyme L-glutamate oxidase (GluOx) and the permselective barrier poly-ortho-phenylenediamine (PPD) onto 125-microm diameter Pt wire electrodes (Pt/PEI/GluOx/PPD). These devices were calibrated amperometrically at 0.7 V
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service