コンテンツへスキップ

70923

BugBuster® (primary amine-free) Extraction Reagent

別名:

Protein Extraction Reagent

ログインで組織・契約価格をご覧ください。

サイズを選択してください

表示を変更する

この商品について

NACRES:
NA.77
UNSPSC Code:
41106511
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします


form

liquid

Quality Segment

manufacturer/tradename

Novagen®

storage condition

OK to freeze, avoid repeated freeze/thaw cycles

input

bacteria and yeast sample(s)

shipped in

ambient

storage temp.

10-30°C

General description

BugBuster (primary amine-free) Protein Extraction Reagent is a special formulation of BugBuster designed for applications where primary amines would interfere if present in the protein extract, such as protein immobilization or cross-linking. The PIPPS buffer used in BugBuster (primary amine-free) has a similar buffer capacity and pH range as the original Tris-buffered BugBuster, but will not complex metal ions, also making it ideally suited for extraction of metal dependent proteins.

Features and Benefits

Primary Amine-Free Formulation: BugBuster® (primary amine-free) Extraction Reagent is specially designed for applications where primary amines would interfere with protein extract. This means that academic researchers can purify metal-dependent proteins or proteins to be used for immobilization or crosslinking without worrying about the presence of primary amines, which could cause interference.

Enhanced Extraction: The extraction process can be further enhanced by the addition of rLysozyme Solution and Benzonase Nuclease, which helps to efficiently extract and purify proteins from the sample.

Metal Ion Compatibility: The PIPPS buffer used in the primary amine-free formulation of BugBuster® has a similar buffer capacity and pH range as the original Tris-buffered BugBuster® but will not complex metal ions. This makes it an ideal choice for extraction of metal-dependent proteins

Legal Information

BUGBUSTER is a registered trademark of Merck KGaA, Darmstadt, Germany
NOVAGEN is a registered trademark of Merck KGaA, Darmstadt, Germany

Disclaimer

Toxicity: Standard Handling (A)


保管分類

10 - Combustible liquids

wgk

WGK 2


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

70923-100ML: + 70923-ML: + 70923-4: + 70923-3: + 70923-500ML:

jan



最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

適切なバージョンが見つかりませんか。

特定のバージョンが必要な場合は、ロット番号またはバッチ番号で特定の証明書を検索できます。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする