ãµã€ãºãéžæããŠãã ãã
ãã®ååã«ã€ããŠ
Quality Segment
manufacturer/tradename
Chemicon®, QCM
technique(s)
cell based assay: suitable
detection method
colorimetric, fluorometric
General description
Cell migration may be evaluated using several different methods; the most widely accepted being the Boyden Chamber assay. The Boyden Chamber system uses a two-chamber plate model in which a porous membrane provides an interface between two chambers. Cells are seeded in the upper chamber and chemoattractants placed in the lower chamber. Cells in the upper chamber migrate toward the chemoattractants by passing through the porous membrane to the lower chamber. Migratory cells are stained and quantified. Most cells are sized from 30 to 50 ÎŒm can migrate through 3 to 10 ÎŒm pore.
Application
Cell Structure
Laminin protein is coated on the bottom of each chamberâ²s porous membrane as the driver for cell migration. A similarly BSA-coated control chamber(s) provides an appropriate migration control. Cells that migrate toward laminin are stained using crystal violet, a nucleic dye, extracted from the membrane surface, and quantified on a microplate reader using spectrophotometry.
Each kit provides sufficient materials for the evaluation of 24 samples.
Packaging
Preparation Note
- ECM220-1 kit components should be stored at 2° to 8°C. DO NOT FREEZE.
- ECM220-2 component must be stored at -20°C until needed.
Other Notes
1. 24-well Cell Migration Plate Assembly - 5 ÎŒm: (Part No. 2005708) Two 24-well plates, each containing 12- 5 ÎŒm pore inserts per plate.
2. BSA 30% solution: (Part No. CS203352) One vial containing 0.5 mL of a 30% solution.
3. Cell Stain Solution*: (Part No. 90144) One bottle.
4. Extraction Buffer: (Part No. 90145) One bottle.
5. 24-well Stain Receiver Plate: (Part No. PIMWS2450) One each.
6. 96-Well Stain Quantitation Plate: (Part No. 2005870) One each.
7. Swabs: 50 ea
8. Forceps: 1 pair
*Caution: Cell Stain Solution contains a small amount of crystal violet, which is toxic if swallowed or inhaled, and may cause irritation to the eyes, respiratory system, and skin. Handle with caution.
ECM220-2
1. Laminin: (Part No. CS202685) Two vials each containing 60 ÎŒg in solution.
Legal Information
Disclaimer
Still not finding the right product?
Explore all of our products under QCM Laminin Migration Assay (24-well, colorimetric)
泚æåèµ·èª
Danger
ãã¶ãŒãã³ãŒã
Hazard Classifications
Eye Irrit. 2 - Flam. Liq. 2
ä¿ç®¡åé¡
3 - Flammable liquids
WGK
WGK 1
é©çšæ³ä»€
詊éšç ç©¶çšéãèæ ®ããé¢é£æ³ä»€ãäž»ã«æããŠãããŸããååŠç©è³ªä»¥å€ã«ã€ããŠã¯ãäžéšã®æ å ±ã®ã¿æäŸããŠããŸãã 補åãå®å šãã€åæ³çã«äœ¿çšããããšã¯ã䜿çšè ã®çŸ©åã§ããææ°æ å ±ã«ããä¿®æ£ãããå ŽåããããŸããWEBã®åæ ã«ã¯æéãèŠããããšããããããé©å®SDSããåç §ãã ããã
Please refer to KIT Component information
pdsc
Please refer to KIT Component information
prtr
Please refer to KIT Component information
fsl
Please refer to KIT Component information
ishl_indicated
Please refer to KIT Component information
ishl_notified
Please refer to KIT Component information
cart
ãããã³ã³ããŒãã³ãã®æ å ±ãåç §ããŠãã ãã
jan
ææ°ããŒãžã§ã³ã®ãããããéžæããŠãã ããïŒ
以åãã®è£œåãè³Œå ¥ããã ããããšãããå Žå
ææžã©ã€ãã©ãªã§ãæè¿è³Œå ¥ãã補åã®ææžãæ€çŽ¢ã§ããŸãã

