コンテンツへスキップ
Merck

HTS094M

ChemiSCREEN Membrane Preparation Recombinant Human GAL1 Receptor

Human GAL1 GPCR membrane preparation for Radioligand binding Assays & GTPγS binding.

ログインで組織・契約価格をご覧ください。

サイズを選択してください

表示を変更する

この商品について

UNSPSC Code:
41106514
NACRES:
NA.84
eCl@ss:
32161000
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします


biological source

human

Quality Segment

recombinant

expressed in Chem-1 cells

manufacturer/tradename

ChemiScreen, Chemicon®

technique(s)

ligand binding assay: suitable (GTPγS), radioligand binding assay (RLBA): suitable

NCBI accession no.

UniProt accession no.

shipped in

dry ice

storage temp.

-65 to -96°C

General description

Galanin is a 29-30 amino acid peptide originally purified from intestine but later found to be abundant in the CNS. A family of 3 GPCRs, GAL1, GAL2 and GAL3, bind to galanin and mediate its biological effects. Galanin and its receptors have been implicated in pain, cognition, seizure activity, depression and drug addiction (Hokfelt, 2005). In particular, GAL1 mediates the anticonvulsant activity of galanin; mice lacking GAL1 are affected by spontaneous seizures, and have increased susceptibility to seizures induced by lithium-pilocarpine treatment and electrical perforant path stimulation (McColl et al., 2006; Mazarati et al., 2004). Chemicon′s GAL1 membrane preparations are crude membrane preparations made from our proprietary stable recombinant cell lines to ensure high-level of GPCR surface expression; thus, they are ideal HTS tools for screening of antagonists of GAL1 interactions with galanin. The membrane preparations exhibit a Kd of 1.7 nM for [125I]-galanin. With 5 ug/well GAL1 Membrane Prep and 0.25 nM [125I]-galanin, a greater than 50-fold signal-to-background ratio was obtained.
Human GAL1

Application

Radioligand binding assay, and GTPγS binding.

Biochem/physiol Actions

GPCR Class: A
Protein Target: GAL1
Target Sub-Family: Galanin

Features and Benefits

Inucbation Conditions
Membranes are mixed with radioactive ligand and unlabeled competitor (see Figures 1 and 2 for concentrations tested) in binding buffer in a nonbinding 96-well plate, and incubated for 1-2 h. Prior to filtration, a GF/C 96-well filter plate is coated with 0.33% polyethyleneimine for 30 min, then washed with 50 mM HEPES, pH 7.4, 0.5% BSA. Binding reaction is transferred to the filter plate, and washed 3 times (1 mL per well per wash) with Wash Buffer. The plate is dried and counted.

Binding buffer: 50 mM Hepes, pH 7.4, 5 mM MgCl2, 1 mM CaCl2, 0.2% BSA, filtered and stored at 4°C Radioligand: [125I] galanin (Perkin Elmer # NEX333)

Wash Buffer: 50 mM Hepes, pH 7.4, 500mM NaCl , 0.1% BSA, filtered and stored at 4°C.

Packaging

1 mL per vial

Physical form

One package contains enough membranes for at least 200 assays (units), where an unit is the amount of membrane that will yield greater than 50-fold signal:background with 125I-labeled galanin at 0.25 nM.

Liquid in packaging buffer: 50 mM Tris pH 7.4, 10% glycerol and 1% BSA with no preservatives. Packaging method: Membranes protein were adjusted to the indicated concentration in packaging buffer, rapidly frozen, and stored at -80°C.

Preparation Note

Maintain frozen at -70°C for up to 2 years. Do not freeze and thaw.

Analysis Note

SPECIFICATIONS: 1 unit = 5 ug membrane preparation Bmax: 19.2 pmol/mg Kd: 1.7 nM

10 µg/well5 µg/well
Signal:Background 77.6 75.6
Specific Binding (cpm) 38414 37384

Legal Information

CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany

Disclaimer

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.


保管分類

12 - Non Combustible Liquids

一体何が起きているの?

WGK 2


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

HTS094M:

jan



最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

適切なバージョンが見つかりませんか。

特定のバージョンが必要な場合は、ロット番号またはバッチ番号で特定の証明書を検索できます。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする