Polysep™ II 1.0/0.2 µm nominal, Opticap® XL Capsule

inlet connection diam. 1-1/2 in., Opticap® XL 5, pore size 1.0/0.2 μm, cartridge nominal length 5 in. (12.5 cm)

別名:

Opticap XL5 Polysep II 1.0/0.2 μm 1-1/2 in. TC/TC, Polysep II 1.0/0.2 µm nominal, Opticap® XL Capsule

ログインで組織・契約価格をご覧ください。

サイズを選択してください

表示を変更する

この商品について

UNSPSC Code:
23151806
NACRES:
NB.24
eCl@ss:
32031610
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします


製品名

Polysep II 1.0/0.2 µm(公称)、Opticap® XLカプセル, Chemistry: Mixed Cellulose Esters (MCE)Inlet: 1-1/2 in. Sanitary FlangeOutlet: 1-1/2 in. Sanitary FlangeMax Operating Pressure: 80 psi @ 25 °C

Quality Level

material

borosilicate glass fiber (BGF) membrane, mixed cellulose esters (MCE) membrane, polypropylene , polypropylene housing, polypropylene support, polypropylene vent cap, silicone seal

reg. compliance

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

sterility

non-sterile

sterilization compatibility

autoclavable compatible

product line

Opticap® XL 5

feature

hydrophilic

manufacturer/tradename

Opticap®

parameter

1.0 bar max. inlet pressure (15 psi) at 80 °C, 2.75 bar max. inlet pressure (40 psi) at 60 °C, 25 °C max. inlet temp., 3.5 bar max. differential pressure (50 psid) at 25 °C, 5.5 bar max. inlet pressure (80 psi) at 23 °C, 80 psig max. inlet pressure

technique(s)

prefiltration: suitable

L

21.6 cm (8.5 in.)

W

4.2 in.

cartridge nominal length

5 in. (12.5 cm)

diam.

14.5 cm (5.7 in.)

filtration area

0.19 m2

inlet connection diam.

1-1/2 in.

inlet to outlet W

21.6 cm (8.5 in.)

outlet connection diam.

1-1/2 in.

impurities

≤0.5 EU/mL (LAL test, Aqueous extraction), <0.5  EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

gravimetric extractables

≤61 mg/capsule

matrix

Polysep II

pore size

1.0/0.2 μm nominal pore size, 1.0/0.2 μm pore size

fitting

inlet sanitary flange, outlet sanitary flange, (38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)

shipped in

ambient

Features and Benefits

Format: Double Layer

Analysis Note

Gravimetric Extractables: after a 5 L flush and 24 hours in water at controlled room temperature

Other Notes

Replaces: SN1M040A8
Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer to the first page of Visual Inspection Guide and introduction section of the Mixed cellulose esters Tech Brief
  • Storage Statement: Please refer to the Mixed cellulose esters Tech Brief
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Legal Information

OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany
Polysep is a trademark of Sigma-Aldrich Co. LLC


Still not finding the right product?


保管分類

11 - Combustible Solids

wgk

WGK 2



試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする





グローバルトレードアイテム番号

カタログ番号GTIN
KGW3A05TT104053252248450