コンテンツぞスキップ
Merck

SCT012M

LuminiCell Tracker 540- Vascular Labeling Kit

Biocompatible organic fluorescent nanoparticles (AIEDots) that can be used to fluorescently tag vasculature in living tissues and animals for studies of inflammation and vascular leakage.

別名:

AIEDots Cell Tracker Dye, AIE Live Cell Fluorescent Dye, Fluorescent Cell Tracking Dye, Live Cell Fluorescent Nanoparticles

ログむンで組織・契玄䟡栌をご芧ください。

サむズを遞択しおください

衚瀺を倉曎する

この商品に぀いお

UNSPSC Code:
12352207
NACRES:
NA.47
eCl@ss:
32161000
テクニカルサヌビス
お困りのこずがあれば、経隓豊富なテクニカルサヌビスチヌムがお客様をサポヌトしたす。
お手䌝いしたす


Quality Segment

technique(s)

cell culture | mammalian: suitable

detection method

fluorometric

General description

Absorbance Maximum: 423nm
Emisson Maximum: 540nm

Suggested Filters:
Excitation: 405/458/488nm
Emisson: 480-560nm
Long-term noninvasive cell tracking by fluorescent probes and quantum dots is of great importance to life science and biomedical engineering. Current methods used to fluorescently tag cells have been limited by short signal duration, high background auto-fluorescence or lengthy molecular cloning manipulations using GFP. LuminiCell Trackers<TMSYMBOL></TMSYMBOL> are biocompatible organic fluorescent nanoparticles based on Aggregation Induced Emission technology, termed AIEDots. Aggregation induced emission (AIE) molecules emit fluorescence in an opposite manner than other common fluorophores (Quantum Dots, GFP). Propeller-shaped AIE fluorogens are non-emissive in solutions but become highly fluorescent upon aggregate formation. Due to these differences, LuminiCell Trackers<TMSYMBOL></TMSYMBOL> have very high fluorescence intensities with minimal signal quenching allowing live cell fluorescent tagging for up to 10 days in vitro and 21 days in vivo. These properties make them optimal candidates for long interval live cell bioimaging experiments.

The Luminicell Tracker<TMSYMBOL></TMSYMBOL>-540 Vascular Labeling Kit contain green fluorescent AIEDots nanoparticles without TAT sequences. These nanoparticles can be used to fluorescently tag vasculature in living tissues and animals for studies of inflammation and vascular leakage.

Features and Benefits

● Brighter: 10X brighter than other cell labeling technologies
● Photostable: 3X longer fluorescence without signal quenching
● Biocompatible: Non-toxic organic nanoparticles intended for biological applications
● Rapid Protocol: Easy-to-use protocol labels cells within 4 hours

Application

Biocompatible organic fluorescent nanoparticles (AIEDots) that can be used to fluorescently tag vasculature in living tissues and animals for studies of inflammation and vascular leakage.

Physical form

500nM in 0.5ml PBS, pH 7.4

Preparation Note

Store at -2-8°C upon receipt. Thaw at room temperature or in a water bath. Do not Freeze.

Note: Some particulates may form as a result of nanoparticle aggregation during shipping. To get particulates back in solution, sonicate the vial containing LuminiCell Tracker three times for 1 min each before use.

Analysis Note

Absorbance: 422+-5nM
Concentration: 180-220nM
Fluorescence: 540+/- 10nm
Quantum Yield: ≥50%
Brightness at 540nM: ≥3X10^7 M-1cm-1

Disclaimer

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.


保管分類

12 - Non Combustible Liquids

wgk

WGK 2

flash_point_f

Not applicable

flash_point_c

Not applicable


適甚法什

詊隓研究甚途を考慮した関連法什を䞻に挙げおおりたす。化孊物質以倖に぀いおは、䞀郚の情報のみ提䟛しおいたす。 補品を安党か぀合法的に䜿甚するこずは、䜿甚者の矩務です。最新情報により修正される堎合がありたす。WEBの反映には時間を芁するこずがあるため、適宜SDSをご参照ください。

SCT012:

jan



詊隓成瞟曞COA

補品のロット番号・バッチ番号を入力しお、詊隓成瞟曞COA を怜玢できたす。ロット番号・バッチ番号は、補品ラベルに「Lot」たたは「Batch」に続いお蚘茉されおいたす。

以前この補品を賌入いただいたこずがある堎合

文曞ラむブラリで、最近賌入した補品の文曞を怜玢できたす。

文曞ラむブラリにアクセスする