제품정보 (DICE 배송 시 비용 별도)
Linear Formula:
Cl2C6H3OH
CAS 번호:
Molecular Weight:
163.00
UNSPSC Code:
12352100
NACRES:
NA.22
PubChem Substance ID:
EC Number:
201-761-3
Beilstein/REAXYS Number:
1447806
MDL number:
Assay:
99%
Form:
crystals
Quality Level
assay
99%
form
crystals
bp
218-220 °C (lit.)
mp
64-66 °C (lit.)
SMILES string
Oc1c(Cl)cccc1Cl
InChI
1S/C6H4Cl2O/c7-4-2-1-3-5(8)6(4)9/h1-3,9H
InChI key
HOLHYSJJBXSLMV-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
signalword
Danger
hcodes
Hazard Classifications
Skin Corr. 1B
저장 등급
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
wgk
WGK 2
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges
Lígia Miranda Ferreira Borges et al.
Veterinary parasitology, 147(1-2), 155-160 (2007-04-27)
This study was carried out with the objective of evaluating the efficacy of a 2,6-dichlorophenol (2,6-DCP) lure to control Dermacentor nitens (Acari: Ixodidae). Slow-release formulations of the pheromone formulated with and without cypermethrin were prepared. Olfactometer bioassays were used to
Davide Vione et al.
Chemosphere, 69(10), 1548-1554 (2007-07-10)
2,4-Dichlorophenol (2,4-DCP) and 2,6-dichlorophenol (2,6-DCP) undergo oxidation, nitrosation and nitration in the presence of nitrate under UV irradiation. Nitration is favoured under acidic conditions, most likely because HNO(2) is formed on nitrate photolysis. The most likely photonitration pathway is the
Yu Tian et al.
Water research, 47(1), 279-288 (2012-11-06)
Distribution variation of a metabolic uncoupler, 2,6-dichlorophenol (2,6-DCP), in long-term sludge culture was studied, and the effects on sludge reduction and biological inhibition of this chemical during the 90-day operation were established. The extracellular polymeric substance (EPS) matrix functioned as
S Almeda et al.
Analytica chimica acta, 587(1), 97-103 (2007-03-28)
Actually there is a great trend on the development of effective analytical methods for monitoring trace levels of various phenols which can indicate, among others compounds, the water quality. A simple, inexpensive supported liquid membrane (SLM) device was used in
Anna Maria Polcaro et al.
Journal of hazardous materials, 148(3), 505-512 (2007-04-07)
This paper presents the results of a study on the electrokinetic treatment of kaolinite and humic acid kaolinite complexes spiked with 2,6-dichlorophenol or 3-(3,4-dichlorophenyl)-1,1-dimethylurea (diuron). In particular, the attention was paid to the interaction between solid surface and dissolved organics:
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.