제품 이름
OPTICAP® XLT 10 Capsule Media: MILLIPORE EXPRESS® SHF 0.2 µm, Chemistry: Hydrophilic Polyethersulfone (PES) Inlet: 5/8 in. Hose Barb Outlet: 5/8 in. Hose Barb T-line Max Operating Pressure: 80 psi @ 25 °C
Quality Segment
material
polyester support, polypropylene device (gamma stable), polypropylene housing, polypropylene vent cap, polysulfone device, silicone seal
reg. compliance
meets FDA 21 CFR 177-182 (all component materials)
sterility
non-sterile
sterilization compatibility
gamma compatible
product line
Opticap® XLT 10
feature
hydrophilic
manufacturer/tradename
Millipore Express®
parameter
≤32.7 mL/min air diffusion at 2.8 bar (40 psig) (in water), 1.0 bar max. differential pressure (15 psid) at 80 °C (Forward), 1.0 bar max. inlet pressure (15 psi) at 80 °C, 100 psi max. differential pressure (6.9 bar) (intermittent), 2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent), 2.75 bar max. inlet pressure (40 psi) at 60 °C, 25 °C max. inlet temp., 5.5 bar max. differential pressure (80 psid) at 25 °C (Forward), 5.5 bar max. inlet pressure (80 psi) at 25 °C, 6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent), 6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent), 80 psi max. differential pressure (5.5 bar) (continuous), 80 psig max. inlet pressure
technique(s)
sterile filtration: suitable
W
7.8 in.
cartridge nominal length
10 in. (25 cm)
device L
37.6 cm (14.8 in.)
device size
10 in.
filter diam.
10.7 cm (4.2 in.)
filter filtration area
0.57 m2
impurities
≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction), <0.25 EU/mL USP bacterial endotoxins (sample aqueous extraction)
matrix
Millipore Express® SHF
pore size
0.2 μm pore size
bubble point
≥4000 mbar (58 psig), air with water
fitting
(16 mm (5?8 in.) Hose Barb Inlet and Outlet)
General description
Packaging
Preparation Note
Gamma Compatible to 45 kGy. May be autoclaved for 3 cycles of 60 min at 123 °C; not in-line steam sterilizable
Analysis Note
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Legal Information
Still not finding the right product?
Explore all of our products under OPTICAP® XLT 10 Capsule Media: MILLIPORE EXPRESS® SHF 0.2 µm
Emprove® 프로그램을 사용하여 GMP 준수 유지
Emprove® Dossiers로 자격을 가속화하고, 규정 준수를 유지하며, 시간을 절약하세요.
주: EmproveSuite.com으로 이동하게 됩니다. 귀하의 사용자 이름과 비밀번호는 시그마알드리치닷컴과는 별개이며 다를 수 있습니다.
무료로 등록하고 몇 분 안에 Emprove® Dossiers에 액세스하세요. 구독 플랜을 업그레이드하여 Emprove® Suite에서 고급 및 맞춤형 콘텐츠를 잠금 해제하세요.