콘텐츠로 건너뛰기
Merck

I5505

Indoxyl phosphate disodium salt

≥94% (HPLC), crystalline

동의어(들):

3-Indoxyl phosphate disodium salt, Disodium 3-indoxyl phosphate

조직 및 계약 가격을 보려면 로그인를 클릭합니다.

크기 선택


제품정보 (DICE 배송 시 비용 별도)

실험식(Hill 표기법):
C8H6NNa2O4P
CAS 번호:
Molecular Weight:
257.09
NACRES:
NA.83
PubChem Substance ID:
UNSPSC Code:
12352204
EC Number:
222-014-8
MDL number:
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의

제품 이름

Indoxyl phosphate disodium salt, crystalline

InChI key

WCSKWBKPKXJWEG-UHFFFAOYSA-L

InChI

1S/C8H8NO4P.2Na/c10-14(11,12)13-8-5-9-7-4-2-1-3-6(7)8;;/h1-5,9H,(H2,10,11,12);;/q;2*+1/p-2

SMILES string

[Na+].[Na+].[O-]P([O-])(=O)Oc1c[nH]c2ccccc12

assay

≥94% (HPLC)

form

crystalline

solubility

water: 5 mg/mL, clear to slightly hazy

storage temp.

−20°C

Quality Level

General description

Histochemical substrate for alkaline phosphatase.

저장 등급

11 - Combustible Solids

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type N95 (US)


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

T Kanno et al.
Nihon Shokakibyo Gakkai zasshi = The Japanese journal of gastro-enterology, 90(4), 782-788 (1993-04-01)
We assessed a clinical usefulness of JSCC (Japan Society of Clinical Chemistry) recommended method for the measurement of serum alkaline phosphatase. The recommended method is completely correlated both in the liver-bone and intestine isoenzymes with Kind-King method recommended by the
Pablo Fanjul-Bolado et al.
Analytical chemistry, 79(14), 5272-5277 (2007-06-16)
Alkaline phosphatase (AP) is one of the most used enzymatic labels for the development of ELISAs, immunosensors, DNA hybridization assays, etc. This enzyme catalyzes the dephosphorylation of a substrate into a detectable product usually quantified by optical or electrochemical measurements.
David Hernández-Santos et al.
Analytical chemistry, 76(23), 6887-6893 (2004-12-02)
Voltammetric enzyme genosensors on streptavidin-modified screen-printed carbon electrodes (SPCEs) for the detection of virulence nucleic acid determinants of pneumolysin and autolysin genes, exclusively present on the genome of the human pathogen Streptococcus pneumoniae, were described. Alkaline phosphatase (AP) and 3-indoxyl
Kinetics of the oxidation of indoxyl liberated from indoxyl phosphate by kidney alkaline phosphatase.
S Kirkeby et al.
Basic and applied histochemistry, 26(2), 71-78 (1982-01-01)
Estefanía C Rama et al.
Biosensors & bioelectronics, 88, 34-40 (2016-07-12)
This work describes the use of mass-produced stainless-steel pins as low-cost electrodes to develop simple and portable amperometric glucose biosensors. A potentiostatic three-electrode configuration device is designed using two bare pins as reference and counter electrodes, and a carbon-ink coated

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.