콘텐츠로 건너뛰기
Merck

M2004

N-Methyl-D-glucamine

99.0-100.5% (titration)

동의어(들):

1-Deoxy-1-(methylamino)-D-glucitol, Meglumine

조직 및 계약 가격을 보려면 로그인를 클릭합니다.

크기 선택


제품정보 (DICE 배송 시 비용 별도)

실험식(Hill 표기법):
C7H17NO5
CAS 번호:
Molecular Weight:
195.21
UNSPSC Code:
12352104
NACRES:
NA.22
PubChem Substance ID:
EC Number:
228-506-9
Beilstein/REAXYS Number:
385906
MDL number:
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의

InChI

1S/C7H17NO5/c1-8-2-4(10)6(12)7(13)5(11)3-9/h4-13H,2-3H2,1H3/t4-,5+,6+,7+/m0/s1

SMILES string

CNC[C@H](O)[C@@H](O)[C@H](O)[C@H](O)CO

InChI key

MBBZMMPHUWSWHV-BDVNFPICSA-N

assay

99.0-100.5% (titration)

form

powder

autoignition temp.

~662 °F

mp

129-131.5 °C (lit.)

Quality Level

유사한 제품을 찾으십니까? 방문 제품 비교 안내

General description

N-Methyl-D-glucamine, also known as methylglucamine, is an organic compound that belongs to the class of amino sugars. It is commonly used in pharmaceutical and biochemical applications as a resolving and buffering agent. Salts of N-methyl-D-glucamine have also been used for X-ray contrast media and nuclear imaging agents.

Application

N-Methyl-D-glucamine (NMG) can be used as a reactant to prepare water-soluble polymer for the selective removal of arsenic from aqueous water. It is also used in the development of various resins and gels containing NMG to remove different oxyanions.

저장 등급

11 - Combustible Solids

wgk

WGK 1

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type N95 (US)


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Raphaëlle Renard-Penna et al.
Radiology, 275(2), 458-468 (2015-01-20)
To compare the diagnostic performance of the magnetic resonance (MR) imaging-based Prostate Imaging Reporting and Data System (PI-RADS) and a Likert scale in the detection of prostate cancer in a cohort of patients undergoing initial prostate biopsy. This institutional review
Philipp Kickingereder et al.
Neuro-oncology, 17(8), 1139-1147 (2015-03-11)
To analyze the relevance of dynamic susceptibility-weighted contrast-enhanced MRI (DSC-MRI) derived relative cerebral blood volume (rCBV) analysis for predicting response to bevacizumab (BEV) in patients with recurrent glioblastoma (rGB). A total of 127 patients diagnosed with rGB receiving either bevacizumab
Vidhya M Ravi et al.
Life science alliance, 2(4) (2019-06-30)
When it comes to the human brain, models that closely mimic in vivo conditions are lacking. Living neuronal tissue is the closest representation of the in vivo human brain outside of a living person. Here, we present a method that
Daniel M Sado et al.
Circulation. Cardiovascular imaging, 6(3), 392-398 (2013-04-09)
Anderson-Fabry disease (AFD) is a rare but underdiagnosed intracellular lipid disorder that can cause left ventricular hypertrophy (LVH). Lipid is known to shorten the magnetic resonance imaging parameter T1. We hypothesized that noncontrast T1 mapping by cardiovascular magnetic resonance would
Steven R Breault et al.
AJR. American journal of roentgenology, 200(3), W297-W303 (2013-02-26)
The purpose of this study was to determine the effects of age and fat content on quantitative dynamic contrast-enhanced MRI (DCE-MRI) parameters in the bone marrow of the lumbar spine and pelvis. The interreader reproducibility of this technique will also

관련 콘텐츠

Product Information Sheet

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.