제품 이름
Phosphate buffered saline, BioPerformance Certified, pH 7.4
SMILES string
OP(=O)(O)[O-].OP(=O)([O-])[O-].[Na+].[Na+].[Na+].[Cl-].[Cl-].[K+].[K+]
InChI
InChI=1S/2ClH.2K.3Na.2H3O4P/c;;;;;;;2*1-5(2,3)4/h2*1H;;;;;;2*(H3,1,2,3,4)/q;;5*+1;;/p-5
InChI key
LOKCTEFSRHRXRJ-UHFFFAOYSA-I
grade
BioPerformance Certified
Molecular Biology
form
powder
storage condition
(Keep container tightly closed in a dry and well-ventilated place.)
technique(s)
immunofluorescence: suitable
impurities
BioBurden, tested
endotoxin, tested
color
white
pH
7.4
solubility
water: 9.07-10.0 g/L, clear, colorless
cation traces
Fe: ≤10 ppm
heavy metals (as Pb): ≤5 ppm
suitability
suitable for SDS-PAGE
suitable for molecular biology
application(s)
diagnostic assay manufacturing
histology
sample preparation
foreign activity
DNase, RNase, Protease, none detected
Quality Level
유사한 제품을 찾으십니까? 방문 제품 비교 안내
Application
- Rapid and zero-cost DNA extraction from soft-bodied insects for routine PCR-based applications.: This study used phosphate buffered saline (PBS) to develop a cost-effective and efficient method for DNA extraction from insects, facilitating routine PCR-based applications in molecular biology (Jangra & Ghosh, 2022).
- Injectable amnion hydrogel-mediated delivery of adipose-derived stem cells for osteoarthritis treatment.: PBS was utilized to prepare and deliver adipose-derived stem cells in an injectable hydrogel, showing potential for innovative osteoarthritis treatments (Bhattacharjee et al., 2022).
- Rapid and sensitive detection of SARS-CoV-2 infection using quantitative peptide enrichment LC-MS analysis.: This research employed PBS for sample preparation in a novel LC-MS method for detecting SARS-CoV-2, providing a rapid and sensitive diagnostic tool (Hober et al., 2021).
Other Notes
Packaging
Preparation Note
저장 등급
11 - Combustible Solids
wgk
WGK 1
flash_point_f
Not applicable
flash_point_c
Not applicable
문서
Optimize serum samples for LC-MS/MS-based free testosterone determination using Supel™ BioSPME 96-pin device and validated equilibrium dialysis methods.
The application note describes a comparative analysis of plasma protein binding results for free/bound drugs using two different sample extraction steps, with and without agitation.
Comparative analysis of Supel™ BioSPME 96-Pin device with a rapid equilibrium dialysis technique for accuracy of measured values, sample cleanliness, and workflow time in drug protein binding.
Learn about Supel™ BioSPME C18 high-throughput devices to determine plasma protein binding and decrease the sample preparation time to less than an hour.
프로토콜
Preparation for biodegradable nanoparticles and their use in transfection protocols .
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..