Seleccione un Tamaño
About This Item
LC/MS: suitable
5.2 psi ( 37.7 °C)
~132 mmHg ( 20 °C)
Nombre del producto
Hexano, hypergrade for LC-MS LiChrosolv®
form
liquid
SMILES string
CCCCCC
InChI
1S/C6H14/c1-3-5-6-4-2/h3-6H2,1-2H3
InChI key
VLKZOEOYAKHREP-UHFFFAOYSA-N
vapor density
~3 (vs air)
vapor pressure
256 mmHg ( 37.7 °C)
5.2 psi ( 37.7 °C)
~132 mmHg ( 20 °C)
product line
LiChrosolv®
assay
≥99% (GC)
autoignition temp.
453 °F
expl. lim.
7.7 %
technique(s)
HPLC: suitable
LC/MS: suitable
impurities
≤0.0002 meq/g Acidity
≤0.0002 meq/g Alkalinity
≤0.005% Water
≤10 ppb Al (Aluminium)
≤10 ppb Ca (Calcium)
≤10 ppb Fe (Iron)
≤10 ppb Mg (Magnesium)
≤10 ppb Na (Sodium)
≤5 ppb K (Potassium)
evapn. residue
≤2.0 mg/L
transmittance
210 nm, ≥60%
225 nm, ≥90%
245 nm, ≥98%
refractive index
n20/D 1.375 (lit.)
kinematic viscosity
0.50 cSt(20 °C)
bp
69 °C (lit.)
mp
−95 °C (lit.)
transition temp
flash point -22 °C
density
0.659 g/mL at 25 °C (lit.)
storage temp.
2-30°C
Quality Level
¿Está buscando productos similares? Visita Guía de comparación de productos
Categorías relacionadas
Analysis Note
Identity (IR): conforms
Evaporation residue: ≤ 2.0 mg/l
Water: ≤ 0.005 %
Acidity: ≤ 0.0002 meq/g
Alkalinity: ≤ 0.0002 meq/g
Al (Aluminium): ≤ 10 ppb
Ca (Calcium): ≤ 10 ppb
Fe (Iron): ≤ 10 ppb
K (Potassium): ≤ 5 ppb
Mg (Magnesium): ≤ 10 ppb
Na (Sodium): ≤ 10 ppb
Transmission (at 210 nm): ≥ 60 %
Transmission (at 225 nm): ≥ 90 %
Transmission (from 245 nm): ≥ 98 %
Suitable for LC-MS; Intensity of background mass peak based on reserpine(APCI/ESI positive): ≤ 2 ppb
Suitable for LC-MS; Intensity of background mass peak based on reserpine(APCI/ESI negative): ≤ 20 ppb
Filtered by 0,2 µm filter.
Application
Also used in:
- analysis of mineral oil saturated hydrocarbons in vegetable oils by LC-GC interface.
- studies on sugars and organic acids in biological matrices using GC coupled to triple quadruple mass spectrometry (QqQ-MS).
Features and Benefits
- no ghost peaks
- full reproducibility
- extends the lifetime of columns
- optimized and tested for LC-MS applications
- minimal background ion suppression
- reduced risk of contamination
- less exposure to hazardous chemicals
General description
Other Notes
Preparation Note
Legal Information
signalword
Danger
Hazard Classifications
Aquatic Chronic 2 - Asp. Tox. 1 - Flam. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 2 Inhalation - STOT SE 3
target_organs
Central nervous system, Nervous system
Clase de almacenamiento
3 - Flammable liquids
wgk
WGK 3
flash_point_f
-7.6 °F
flash_point_c
-22 °C
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico