Passive sampling for volatile organic compounds in indoor air-controlled laboratory comparison of four sampler types.

Environmental science. Processes & impacts (2015-04-11)
Todd McAlary, Hester Groenevelt, Stephen Disher, Jason Arnold, Suresh Seethapathy, Paolo Sacco, Derrick Crump, Brian Schumacher, Heidi Hayes, Paul Johnson, Tadeusz Górecki
RESUMEN

This article describes laboratory testing of four passive diffusive samplers for assessing indoor air concentrations of volatile organic compounds (VOCs), including SKC Ultra II, Radiello®, Waterloo Membrane Sampler (WMS) and Automated Thermal Desorption (ATD) tubes with two different sorbents (Tenax TA and Carbopack B). The testing included 10 VOCs (including chlorinated ethenes, ethanes, and methanes, aromatic and aliphatic hydrocarbons), spanning a range of properties and including some compounds expected to pose challenges (naphthalene, methyl ethyl ketone). Tests were conducted at different temperatures (17 to 30 °C), relative humidities (30 to 90% RH), face velocities (0.014 to 0.41 m s(-1)), concentrations (1 to 100 parts per billion by volume [ppbv]) and sampling durations (1 to 7 days). The results show that all of the passive samplers provided data that met the success criteria (relative percent difference [RPD] ≤ 45% of active sample concentrations and coefficient of variation [COV] ≤ 30%) in the majority of cases, but some compounds were problematic for some samplers. The passive sampler uptake rates depend to varying degrees on the sampler, sorbent, target compounds and environmental conditions, so field calibration is advantageous for the highest levels of data quality.

MATERIALES
Número de producto
Marca
Descripción del producto

radiello Adsorbentes de cartucho, for sampling BTEX and VOCs (CS2 Desorption), matrix SS net (100 mesh, 5.8 mm diam.), activated with activated charcoal (30-50 mesh), pk of 20
radiello Adsorbentes de cartucho, for sampling Aldehydes, matrix SS net with 2,4-DNPH coated FLORISIL®, pk of 20
radiello Diffusive Bodies, white, configured for general use, pk of 20
radiello Triangular Support Plate, pk of 20
radiello Adsorbentes de cartucho, for sampling Ammonia (NH3), matrix microporous PE impregnated with phosphoric acid, pk of 20
radiello Diffusive Bodies, yellow, configured for reduced sampling rates, pk of 20
radiello Diffusive Bodies, blue, configured for sampling light sensitive compounds, pk of 20
Supelco
Tubo TD de acero inoxidable desactivado FLM Carbopack X, preconditioned, pkg of 10 tubes, O.D. × L 1/4 in. (6.35 mm) × 3 1/2 in. (89 mm)
radiello Adsorbentes de cartucho, for sampling BTEX and VOCs (thermal desorption), matrix SS net (3 x 8 μm, 4.8 mm diam.), Carbograph, pk of 20
Supelco
Adsorbente Carbopack, matrix Carbopack B, 60-80 mesh, bottle of 10 g
Supelco
Adsorbente Carbopack, matrix Carbopack C, 80-100 mesh, bottle of 10 g
Supelco
radiello Methylene Blue Calibration Standard for H2S (Hydrogen Sulfide), pkg of 100 mL
radiello Outdoor Shelter, pk of 10
Supelco
Adsorbente Carbopack, matrix Carbopack C, 60-80 mesh, bottle of 10 g
Supelco
Adsorbente Carbopack, matrix Carbopack X, 40-60 mesh, bottle of 10 g
radiello BTEX/VOC Starter Kit, CS2 Desorption
Supelco
Adsorbente Carbopack, matrix Carbopack X, 60-80 mesh, bottle of 10 g
radiello BTEX/VOC Starter Kit, Thermal Desorption
radiello Vertical Adapter, threaded for standard use, pk of 20
radiello Diffusive Bodies, permeative, configured for anaesthetic gases and vapors, pk of 20
radiello Barcode Labels, pk of 198
radiello Filtration Kit, pk of 20
radiello Anesthetic Gases and Vapor Sampler
radiello Hydrogen Sulfide Starter Kit
Supelco
radiello BTEX Calibration Kit (Thermal Desorption)
radiello Empty Storage Tubes, polypropylene (with stopper), volume 12 mL, pk of 100
Supelco
Carbopack B, stainless steel TD tube, O.D. × L 1/4 × 3 1/2, unconditioned, pkg of 10 ea
Supelco
radiello Aldehyde Calibration Standard, 50 μg/mL each component in acetonitrile, pkg of 10 mL
radiello Empty Storage Tubes, glass (with stopper), volume 2.8 mL, pk of 100
radiello On-Field Thermometer, Includes one standard Radiello vertical adapter (RAD122) for each thermometer, configured for standard use, pk of 3