コンテンツへスキップ
Merck

1.06035

メタノール

≥99.9% (GC), suitable for LC/MS, LiChrosolv®

別名:

メチルアルコール

ログインで組織・契約価格をご覧ください。

サイズを選択してください


この商品について

化学式:
CH3OH
CAS番号:
分子量:
32.04
NACRES:
NA.03
EC Index Number:
200-659-6
UNSPSC Code:
12191502
MDL number:
Beilstein/REAXYS Number:
1098229
Assay:
≥99.9% (GC)
Technique(s):
HPLC: suitable, LC/MS: suitable
Vapor pressure:
128 hPa ( 20 °C), 410 mmHg ( 50 °C), 97.68 mmHg ( 20 °C)
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします

製品名

メタノール, hypergrade for LC-MS LiChrosolv®

agency

suitable for ASTM® 7968, suitable for ASTM® 7979, suitable for DIN 38407-42, suitable for EPA 1621, suitable for EPA 1633, suitable for EPA 533, suitable for EPA 537.1, suitable for EPA 8327, suitable for EPA ACB B21-02, suitable for EPA ACB B23-05b, suitable for EPA OTM-45, suitable for GB 31604.35-2016, suitable for GB 5009.253-2016, suitable for ISO 21675 2019, suitable for ISO 25101, suitable for ISO/CEN 15968-2010

reg. compliance

suitable for FDA C-010.02

vapor density

1.11 (vs air)

vapor pressure

128 hPa ( 20 °C), 410 mmHg ( 50 °C), 97.68 mmHg ( 20 °C)

product line

LiChrosolv®

assay

≥99.9% (GC)

form

liquid

autoignition temp.

725 °F

potency

5628 mg/kg LD50, oral (Rat), 17100 mg/kg LD50, skin (Rabbit)

Quality Level

technique(s)

HPLC: suitable, LC/MS: suitable

impurities

≤0.0002 meq/g Acidity, ≤0.0002 meq/g Alkalinity, ≤0.01% Water, ≤10 ppb Al (Aluminium), ≤10 ppb Ca (Calcium), ≤10 ppb Fe (Iron), ≤10 ppb Mg (Magnesium), ≤100 ppb Na (Sodium), ≤5 ppb Any further metal (ICP-MS), ≤5 ppb K (Potassium)

evapn. residue

≤1.0 mg/L

transmittance

210 nm, ≥35%, 220 nm, ≥60%, 230 nm, ≥75%, 260 nm, ≥98%

kinematic viscosity

0.54-0.59 cSt(20 °C)

mp

−98 °C (lit.)

transition temp

flash point 9.7 °C

application(s)

PFAS testing

format

neat

storage temp.

2-30°C

類似した製品をお探しですか? 訪問 製品比較ガイド

General description

LiChrosolv hypergrade is accurately tested for LC-MS suitability, and meet all the requirements of modern LC-MS ionization methods (ESI/APCI - positive and negative mode). Thanks to their low level of ionic background and low ion suppression, LiChrosolv hypergrade solvents provide high reproducibility and high ionization efficiency. The packaging material has been improved to meet LC-MS quality requirements perfectly.

Application


  • The composition of chemicals and anti-osteogenic properties in the volatile extracts from Homalomena gigantea rhizome: This study highlights methanol′s role in the extraction and analysis of volatile organic compounds from medicinal plants, providing insights valuable for researchers in pharmacology and natural product chemistry (Thanh et al., 2024).


  • A homochiral tartrate-bridged dinuclear chromium(III) complex anion with a resonance-assisted hydrogen bond for proton conduction: Methanol is used as a solvent in the synthesis of complex inorganic compounds, which are essential in developing new materials for energy applications, such as proton exchange membranes (Dunatov et al., 2024).



Preparation Note

Product filtered through a 0.2 μm filter

Analysis Note

Evaporation Number: 1.9
Purity (GC): ≥ 99.9 %
Identity (IR): conforms
Evaporation residue: ≤ 1.0 mg/l
Water: ≤ 0.01 %
Acidity: ≤ 0.0002 meq/g
Alkalinity: ≤ 0.0002 meq/g
Al (Aluminium): ≤ 10 ppb
Ca (Calcium): ≤ 10 ppb
Fe (Iron): ≤ 10 ppb
K (Potassium): ≤ 5 ppb
Mg (Magnesium): ≤ 10 ppb
Na (Sodium): ≤ 100 ppb
Any further metal (ICP-MS): ≤ 5 ppb
Gradient grade (at 220 nm): ≤ 2.0 mAU
Gradient grade (at 235 nm): ≤ 1.0 mAU
Fluorescence (as quinine at 254 nm): ≤ 1.0 ppb
Fluorescence (as quinine at 365 nm): ≤ 0.5 ppb
Transmission (at 210 nm): ≥ 35 %
Transmission (at 220 nm): ≥ 60 %
Transmission (at 230 nm): ≥ 75 %
Transmission (from 260 nm): ≥ 98 %
Suitable for LC-MS; Intensity of background mass peak based on reserpine(APCI/ESI positive): ≤ 2 ppb
Suitable for LC-MS; Intensity of background mass peak based on reserpine(APCI/ESI negative): ≤ 20 ppb
Filtered by 0.2 µm filter.

Other Notes

Explore various lab safety accessories and equipment for safe handling of solvents to increase your safety level from the first usage.

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
LICHROSOLV is a registered trademark of Merck KGaA, Darmstadt, Germany

signalword

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

target_organs

Eyes,Central nervous system

保管分類

3 - Flammable liquids

flash_point_f

49.5 °F - closed cup

flash_point_c

9.7 °C - closed cup


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

第4類:引火性液体 + アルコール類 + 危険等級II

fsl

名称等を表示すべき危険物及び有害物

ishl_indicated

名称等を通知すべき危険物及び有害物

ishl_notified

1060351000:4548174002933 + 1060352500:4548174002940 + 1060350000: + 1060359185: + 1060354008: + 1060359910: + 106035-BULK: + JP11060351000: + 1060354000:

jan


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

プロトコル

タンポポの花からの禁止されたネオニコチノイド系殺虫剤のQuEChERSおよびLC-Mによる分析。

HPLC Analysis of Polyphenols in Nero d'Avola Red Wine on Discovery® HS C18 (UV 280 nm)

Protocol for HPLC Analysis of Bromelain on TSKgel® BioAssist® S vs. Competitive S Column

すべて表示

関連コンテンツ

Accurately detect and quantify trace nitrosamines (NDMA, NDEA, NEIPA, NDIPA, NDBA, etc.) in pharmaceutical drugs using our complete product portfolio and application guides for LC-MS and GC-MS. Order high-quality reference standards, columns, filters & more.

グローバルトレードアイテム番号

カタログ番号GTIN
1.06035.100004022536071961
1.06035.250004022536071985

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.