製品名
Oxygen Test, titrimetric, for use with MQUANT® titration pipette
analyte chemical class(es)
oxygenates
Quality Segment
application(s)
cannabis testing
compatibility
for use with MQUANT® titration pipette
detection method
titrimetric
storage temp.
15-25°C
General description
Method: titrimetric, acc. to Winkler, with titration pipette MQuant®
The sustainability of biological processes in natural waters is essentially depended on a sufficient oxygen content. The oxygen present in water is also consumed by chemical processes and by microorganisms. This MQuant® Oxygen test (formally MColortest®) is suitable for the titrimetric determination using a graduated syringe.
It can be used in:
Method
In alkaline solution, dissolved oxygen oxidizes manganese(II) ions to form manganese(IV) hydroxides (“oxygen fixation”). In strongly acidic solution these yield manganese(III) ions, which in turn oxidize iodide ions to form iodine. This is then titrated with sodium thiosulfate solution against starch as the indicator until the solution becomes entirely colorless. The oxygen concentration is determined from the consumption of titration solution (iodometric determination acc. to Winkler). The oxygen consumption is calculated as the difference between the oxygen content measured immediately after sampling and that measured after n days (n = 2 to 5).
It can be used in:
- Groundwater, drinking water, and surface water, seawater
- Aquarium water, waters from aquaculture
- Industrial water and wastewater
- Boiler water and boiler feed water
- Beverages
Method
In alkaline solution, dissolved oxygen oxidizes manganese(II) ions to form manganese(IV) hydroxides (“oxygen fixation”). In strongly acidic solution these yield manganese(III) ions, which in turn oxidize iodide ions to form iodine. This is then titrated with sodium thiosulfate solution against starch as the indicator until the solution becomes entirely colorless. The oxygen concentration is determined from the consumption of titration solution (iodometric determination acc. to Winkler). The oxygen consumption is calculated as the difference between the oxygen content measured immediately after sampling and that measured after n days (n = 2 to 5).
Legal Information
MCOLORTEST is a registered trademark of Merck KGaA, Darmstadt, Germany
MQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany
注意喚起語
Danger
一体何が起きているの?
WGK 3
Hazard Classifications
Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Dam. 1 - Met. Corr. 1 - Repr. 1B - Skin Corr. 1A - STOT RE 2
標的臓器
Brain
保管分類
6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects
引火点 (F)
Not applicable
引火点(°C)
Not applicable
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
Please refer to KIT Component information
pdsc
Please refer to KIT Component information
prtr
Please refer to KIT Component information
fsl
Please refer to KIT Component information
ishl_indicated
Please refer to KIT Component information
ishl_notified
Please refer to KIT Component information
cart
キットコンポーネントの情報を参照してください
jan